...
Surgical Positioning Platform

Operating Table Manufacturer for General Surgery, Orthopedic, and C-Arm Use

We manufacture electric, electro-hydraulic, and mechanical operating tables for hospitals, distributors, and surgical project buyers who need stable positioning, radiolucent imaging access, and dependable long-term service. Configurations cover general surgery, orthopedics, gynecology, urology, and bariatric applications, with factory-direct documentation for tenders and registration.

Meja Operasi (also called surgical tables or OT tables — short for operation theatre tables) are motorized or hydraulic patient positioning platforms used in operating rooms to provide stable, adjustable support during surgical procedures. Sanyang Medical manufactures electric and electro-hydraulic operating tables with safe working loads up to 300 kg, radiolucent C-arm compatible tabletops, and CE/ISO 13485 certified quality for hospital procurement teams and medical equipment distributors worldwide.

C-Arm Compatible Radiolucent tops and 300 mm longitudinal slide support imaging-intensive procedures.
Up to 300 kg Load Reinforced lifting columns and sealed hydraulics for stable bariatric positioning.
Zero-Leakage Commitment Pressure-tested hydraulic circuits with battery backup for uninterrupted surgery.
Jajaran Seri

Compare Electric, Electro-Hydraulic, and Mechanical Operating Tables

Global demand for surgical operating tables continues to grow at roughly 6% per year, driven by hybrid OR construction and bariatric case volumes. The right drive system depends on your procedure mix, imaging intensity, and in-house maintenance capability — this comparison is how we advise distributors to position each series.

Seri Drive System Beban Kerja Aman Positioning Control Profil Pemeliharaan Best Fit
Electric (Electromechanical) Low-voltage DC linear actuators with hand pendant Hingga 250 kg Programmable memory positions, one-touch level reset No hydraulic oil; actuator and battery checks only General surgery High-throughput ORs, day-surgery centers
Electro-Hydraulic Electric pump driving sealed hydraulic cylinders Up to 300 kg Smoothest, jitter-free articulation under full load Sealed circuit; annual pressure-hold inspection Complex & bariatric Orthopedics, trauma, hybrid OR imaging
Mechanical (Manual-Hydraulic) Foot-pump hydraulics with gear-driven sections Up to 200 kg Manual cranks and levers; no power dependency Simplest service; minimal spare-parts needs Budget projects Rural hospitals, backup rooms, tender entry lines
Obstetric & Specialty Electric or manual, procedure-specific layout Up to 200 kg Rapid conversion between exam, delivery, and procedure positions Matched to base drive type Maternity & gyne LDR rooms, gynecology and urology clinics
Data Teknis

Reference Specifications for Surgical Table Buyer Comparison

Core parameters for our standard operating room table configurations. Specialized orthopedic, imaging, and bariatric modifications are available on request — share your tender schedule and we will map each line item.

Beban Kerja Aman Up to 300 kg (660 lbs) on heavy-duty electro-hydraulic models; 250 kg electric; 200 kg mechanical
Table Dimensions (L x W) Approx. 2000 mm x 500 mm (accessory rails along full length)
Rentang Elevasi 700 mm – 1000 mm, electrically or hydraulically adjustable; low position supports seated surgeon work
Trendelenburg / Terbalik ± 25° under rated load
Kemiringan Lateral (Kiri/Kanan) ± 15°
Back / Leg Section Back up ≥ 70°, down ≥ 15°; split leg plates adjustable independently
Kompatibilitas C-Arm Radiolucent tabletop panels with longitudinal sliding up to 300 mm for full-length imaging windows
Control & Safety Hand pendant plus column override panel; position locks prevent unintended movement
Tingkat Kebisingan ≤ 50 dB during electro-hydraulic actuation
Power Supply & Backup 110-240 V, 50/60 Hz with built-in battery supporting 50-80 articulation cycles
Dasar Kepatuhan Designed and tested in alignment with IEC 60601-1 and IEC 60601-2-46 (operating tables); manufactured under ISO 13485
Jumlah Pesanan Minimum (MOQ) 10 Unit per model, mixed-model container loading supported
Core Technology

Engineering Deep Dive: Imaging, Load, and Actuation

Three engineering decisions determine whether an operating table earns its place in a modern OR. Here is exactly how we build each one — with the parameters your biomedical team will verify.

Radiolucent operating tabletop section designed for C-arm X-ray transmission
Imaging Ready

Radiolucent Top & 300 mm Slide

High-transmittance tabletop panels keep attenuation low for clear fluoroscopy at standard dose settings. The full top slides up to 300 mm longitudinally, so the C-arm gantry reaches head-to-pelvis imaging zones without moving the anesthetized patient — a decisive factor in orthopedic trauma and ERCP workflows.

Reinforced lifting column and base structure of heavy duty operating table
Structural Safety

300 kg Load & Zero-Leakage Hydraulics

Reinforced steel columns and high-density cylinders hold rated load through full Trendelenburg and lateral tilt without drift. Every hydraulic circuit is pressure-hold tested and full-stroke cycled before packing, backing our zero-leakage commitment — the failure mode hospital buyers flag most often in tender evaluations.

Operating table control pendant and column-mounted override panel
Standards-Based

Redundant Control to IEC 60601-2-46

Tables are engineered and tested in alignment with IEC 60601-1 general electrical safety and IEC 60601-2-46 particular requirements for operating tables — covering stability, load-bearing, and protection against unintended movement. Primary hand pendant, column override panel, and battery backup provide three independent layers of control.

Clinical Scenarios

Operating Room Tables Matched to Each Surgical Discipline

Specialty configuration is where procurement projects succeed or fail. These are the four scenario packages we configure most often for hospital and distributor orders.

General surgery electric operating table set to level position

General & Laparoscopic Surgery

Fast level reset, steep Trendelenburg for laparoscopic access, and memory positions that cut turnover time between cases in high-throughput theaters.

Operating table configured for orthopedic lower limb procedure

Orthopedic & Trauma

Radiolucent imaging window plus traction-frame compatibility via standard side rails supports hip, femoral, and tibial nailing under continuous fluoroscopy.

Gynecology examination and procedure table with leg supports

Gynecology & Obstetrics

Purpose-built delivery and examination beds with ergonomic leg supports, integrated fluid collection, and rapid conversion between labor, delivery, and procedure modes.

Bariatric-capable operating table with wide stable base

Bariatric & High-Load Cases

300 kg safe working load with full articulation retained under load — no manual re-blocking, no positioning compromises during long bariatric procedures.

Engineering Reliability

Built for Zero Downtime in the Operating Theater

Hospitals cannot afford equipment failure mid-surgery. Our operating tables are built on redundant safety systems and fluid-resistant architectures to ensure continuous operation across a 10-year service life.

  • Dual Control Systems: A primary hand pendant plus an override panel on the column guarantees positioning control even if one interface fails mid-case.
  • Battery Backup: The integrated high-capacity battery engages instantly during power outages, supporting 50-80 full articulation cycles — enough to finish the procedure list.
  • Fluid Management: Seamless mattress covers and a stainless-steel, shrouded base prevent fluid ingress into actuators and simplify terminal cleaning between cases.
  • Silent Actuation: Electro-hydraulic drive units operate at or below 50 dB, keeping the theater calm during microsurgical and neurosurgical positioning.
  • Position Locking: Mechanical and electronic interlocks hold every section under rated load, eliminating drift during long cases.
Operating table stainless steel base and lifting column engineering detail
Deployment Options

Surgical Table Configurations for Every Department

From robust general surgery platforms to specialized obstetric beds, we manufacture the right foundation for your clinical needs — and pre-configure accessories before shipment so rooms go live faster.

Electric operating table with programmable hand control

Electric Operating Tables

The standard for modern surgical suites: smooth electromechanical positioning, programmable memory for frequent postures, and one-touch zero-leveling. No hydraulic oil means the lightest routine maintenance in the lineup.

Mechanical hydraulic operating table with foot pump and manual cranks

Mechanical Operating Tables

Foot-pump hydraulics and gear-driven sections deliver full positioning without mains power — the proven choice for budget tenders, rural facilities, and backup rooms where service infrastructure is limited.

Obstetric delivery bed configured for labor and delivery room

Obstetric & Specialty Beds

Purpose-built delivery and gynecological tables with ergonomic leg supports, fluid collection basins, and rapid-release mechanisms that support dynamic LDR and minor-procedure workflows.

Configuration & Customization

Accessories, Rails, and OEM Options

Every table ships with standard stainless-steel side rails along the full tabletop length, so third-party and proprietary accessories fit without adapters. Distributors can also order under OEM/ODM terms with localized branding and documentation.

  • Orthopedic Package: Traction frame, boot stirrups, sacral support, and counter-traction post for lower-limb nailing under fluoroscopy.
  • General Surgery Package: Arm boards, anesthesia screen, body straps, shoulder supports, and X-ray cassette channel.
  • Gyne/Urology Package: Knee crutches, leg holders, fluid collection basin, and perineal cut-out mattress set.
  • Mattress Options: 60-80 mm anti-static, fluid-sealed memory foam pads; decubitus-care versions available.
  • OEM/ODM: Private-label branding, localized manuals and labels, and custom color/finish schemes for project tenders — see our OEM & localization program.
Meja operasi dilengkapi dengan aksesori rel samping dan bagian kaki yang dapat diartikulasikan
Manufacturing & QC

Direct Factory Production With Per-Unit Test Records

We control the full process in-house — steel cutting, robotic welding, hydraulic assembly, electrical integration, and final test — so the table you approve as a sample is the table that ships in bulk. Every unit leaves with its own load-test and cycling record.

Sanyang Medical has manufactured operating tables and complete OR equipment at its 15,000 m² factory in Qufu, Shandong since 2015. A 100+ person team covers R&D, welding, assembly, testing, and export support, serving distributors and hospital projects across North America, Europe, Africa, the Middle East, and Southeast Asia.

  1. Incoming inspection: Steel, actuator, and hydraulic-component batches are verified against the locked bill of materials before line release.
  2. Robotic welding & machining: Automated welding fixtures keep base and column joints uniform across the batch; critical surfaces are machined to tolerance.
  3. Hydraulic assembly & pressure-hold test: Sealed pump circuits are filled, bled, and held under pressure to verify our zero-leakage standard before enclosure.
  4. Full-function cycling: Each table completes repeated articulation cycles at rated 300 kg load, plus battery-backup and override-panel checks.
  5. Inspeksi pra-pengiriman: Cosmetic, electrical safety, and packing checks per AQL sampling; third-party inspection (SGS/TÜV/BV) welcomed at buyer request.
Jalur produksi meja operasi di dalam pabrik Sanyang Medical
Operating table assembly and quality inspection station
Finished operating tables undergoing pre-shipment testing
Kepatuhan & Dokumen

Certifications & Export-Ready Documentation

Operating tables are manufactured under an ISO 13485 quality management system and engineered in alignment with IEC 60601-1 and IEC 60601-2-46 safety requirements. We supply complete documentation packs — certificates, test reports, declarations, and apostilled legalizations — to support local registration, tender bidding, and customs clearance.

Sertifikat CE

Menegaskan kepatuhan terhadap standar keselamatan dan kinerja perangkat medis Eropa.

Unduh PDF

Sertifikat ISO 13485

Mensertifikasi sistem manajemen mutu komprehensif kami untuk pembuatan perangkat medis.

Unduh PDF

Sertifikat Penjualan Bebas

Dokumen penting untuk registrasi produk dan izin impor di banyak pasar internasional.

Unduh PDF
Delivery Capability

Lead Time, Packing, and Export Logistics

Project timelines matter as much as specifications. Our export team plans production and freight around your commissioning date, and consolidates operating tables with lights, pendants, and beds in mixed containers to cut landed cost.

  • Production lead time: Typically 25-35 days after deposit and specification confirmation; priority scheduling for tender deadlines.
  • MOQ & consolidation: 10 units per model; mixed-model and mixed-category loading (tables + lampu bedah + gantungan) in one container.
  • Export packing: Fumigation-free plywood cases with foam blocking, moisture barrier, and tilt indicators; flat-pack options reduce freight volume.
  • Trade terms: EXW, FOB, CIF, and DDP supported; full document set (CI, PL, CO, B/L, certificates) issued per shipment.
  • Installation support: English installation manuals, wiring diagrams, and video guidance; on-site commissioning available for turnkey projects.
Operating table prepared for export packing and container loading
Warranty & Service

Warranty, Spare Parts, and Distributor Support

Distributors win repeat business on service, not on first price. We structure after-sales so your local team can maintain tables confidently without factory escort for every issue.

  • Warranty: Minimum 12 months from delivery covering structure, actuation systems, and control electronics; extended terms negotiable for project orders.
  • Spare parts: Long-term parts availability for hand pendants, actuators, hydraulic seals, batteries, and mattresses, with 48-hour dispatch on stocked items — see our spare parts & service program.
  • Technical support: English troubleshooting guides, wiring diagrams, and video-call diagnostics for your biomedical engineers.
  • Pelatihan: Remote operator and maintenance training for hospital staff and distributor technicians on request.
  • Failure-mode honesty: If a table shows hydraulic seepage or load-drift within warranty, we service or replace under our quality commitment — no dispute loops.
Operating table control components prepared for after-sales service
Basis Pengetahuan

Questions Hospitals and Distributors Ask Before Ordering Operating Tables

Straight answers on imaging compatibility, drive-system selection, leakage risk, sample consistency, and commercial terms.

Ajukan Pertanyaan Khusus
Apakah meja operasi Anda kompatibel dengan pencitraan C-arm?

Ya. Meja operasi kami menggunakan panel meja radiolusen dan bagian atas geser memanjang dengan jarak tempuh hingga 300 mm, menciptakan jendela pencitraan bebas logam yang lebar. Ini mendukung fluoroskopi lengan-C dalam prosedur ortopedi, trauma, urologi, dan kardiovaskular tanpa memposisikan ulang pasien.

Berapa kapasitas berat maksimum untuk pasien bariatrik?

Model listrik dan elektro-hidraulik tugas berat kami dirancang dengan kolom pengangkat yang diperkuat dan silinder hidraulik kepadatan tinggi, mendukung beban kerja aman hingga 300 kg (660 lbs) di seluruh rentang artikulasi penuh, termasuk Trendelenburg dan kemiringan lateral.

Bagaimana pembeli harus memilih antara meja operasi listrik, elektro-hidrolik, dan mekanis?

Meja elektro-hidrolik memberikan artikulasi paling halus dan tenang serta kapasitas beban tertinggi, cocok untuk operasi kompleks dan bariatrik. Meja listrik (elektromekanis) menawarkan posisi memori yang dapat diprogram dan perawatan rutin yang lebih rendah. Meja mekanis merupakan opsi masuk yang berorientasi anggaran untuk fasilitas dengan kebutuhan posisi dasar dan infrastruktur servis terbatas. Kami merekomendasikan untuk menyesuaikan sistem penggerak dengan kompleksitas prosedur, permintaan pencitraan, dan kemampuan pemeliharaan biomedis Anda.

Bagaimana cara mencegah kebocoran oli hidrolik?

Rangkaian hidrolik dirakit dengan unit pompa tertutup dan selang bertekanan tinggi, kemudian diverifikasi dengan uji penahan tekanan dan siklus langkah penuh pada setiap unit sebelum dikemas. Komitmen tanpa kebocoran kami berarti setiap meja yang menunjukkan rembesan dalam periode garansi akan diperbaiki atau diganti sesuai jaminan kualitas kami.

Bagaimana Anda memastikan keandalan selama pemadaman listrik?

Semua meja operasi listrik dan elektro-hidrolik termasuk cadangan baterai berkapasitas tinggi bawaan yang aktif secara otomatis saat listrik padam, mendukung sekitar 50 hingga 80 siklus artikulasi penuh sehingga prosedur dapat diselesaikan dengan aman. Kontrol override manual pada kolom menyediakan lapisan redundansi kedua.

Apakah meja dapat dikonfigurasi dengan rangka traksi ortopedi dan aksesori khusus lainnya?

Ya. Meja dilengkapi dengan rel samping baja tahan karat standar yang kompatibel dengan berbagai aksesori modular, termasuk rangka traksi ortopedi, penyangga kaki, papan lengan, layar anestesi, dan penempat kepala. Paket khusus untuk ortopedi, ginekologi, dan urologi dapat dikonfigurasi sebelum pengiriman.

Bagaimana cara Anda menjaga konsistensi pesanan dalam jumlah besar dengan sampel yang disetujui?

Kami mengunci sampel emas dan dokumen teknis pada saat konfirmasi pesanan. Produksi massal mengikuti bill of materials, perlengkapan pengelasan, dan protokol pengujian yang sama, dan setiap batch lulus inspeksi penerimaan, dalam proses, dan pra-pengiriman dengan uji beban dan siklus yang dicatat per unit. Inspeksi pra-pengiriman pihak ketiga dipersilakan.

Apa itu MOQ, waktu tunggu, dan ketentuan garansi?

MOQ standar adalah 10 unit per model dengan pengisian kontainer campuran (mixed-model) tersedia. Waktu produksi tipikal adalah 25 hingga 35 hari setelah deposit dan konfirmasi spesifikasi. Setiap meja operasi memiliki garansi setidaknya 12 bulan sejak pengiriman, didukung oleh pasokan suku cadang seumur hidup dan dukungan teknis jarak jauh.

Apa perbedaan antara meja operasi listrik dan hidrolik?

Electric operating tables use low-voltage DC linear actuators with programmable memory positions and oil-free maintenance, rated to 250 kg. Hydraulic (electro-hydraulic) tables drive sealed cylinders for smoother, quieter articulation under loads up to 300 kg, making them the standard for orthopedic, bariatric, and C-arm imaging cases. Our electric vs. hydraulic comparison guide covers selection in detail.

Berapa harga meja operasi?

Surgical table (OT table) pricing is driven by drive system, safe working load, C-arm radiolucency, and specialty accessories. Mechanical foot-pump tables are the lowest-cost entry point, electric models sit mid-range, and electro-hydraulic C-arm compatible configurations with orthopedic traction frames carry the highest price. As a factory-direct operating table manufacturer, we quote per configuration — send your tender BOQ for pricing.

Apa itu meja operasi yang kompatibel dengan C-arm?

A C-arm compatible operating table lets a mobile C-arm X-ray unit image the patient without obstruction. It combines radiolucent (X-ray transparent) tabletop panels, a longitudinal sliding top — up to 300 mm on our models — and an open C-shaped base so the gantry can orbit from head to pelvis. This is essential for orthopedic trauma, urology, and cardiovascular fluoroscopy.

Berapa beban kerja aman dari meja operasi?

Safe working load (SWL) is the maximum patient-plus-accessory weight an operating table can hold through full articulation, including Trendelenburg tilt. Standard electric tables are rated around 200–250 kg, while heavy-duty electro-hydraulic models reach 300 kg (660 lbs) for bariatric surgery. Every Sanyang table is load-tested at rated capacity before shipment, with the test record included in the export documentation.

Do you offer orthopedic operating tables?

Yes. As an orthopedic operating table manufacturer, we configure electric and electro-hydraulic tables with traction frames, boot stirrups, sacral supports, and counter-traction posts for hip, femoral, and tibial nailing. Radiolucent tabletops support continuous C-arm fluoroscopy, and each orthopedic package ships pre-assembled with the table, backed by long-term spare-parts supply.

Complete the Room

Related Products and Operating Room Solutions

Operating tables are usually procured as part of a wider theater package. These categories ship from the same factory and consolidate into one container and one document set.

Start Your Project

Get a Configured Operating Table Quote Within 24 Hours

Send your tender schedule, target configuration, or a photo of your current room. Our export engineers will reply with a matched model proposal, C-arm compatibility confirmation, accessory list, and container-loading plan.

Kembali ke atas
Butuh penawaran cepat? Chat dengan tim ekspor kami di WhatsApp.