Sanyang Medical memproduksi troli medis dari ABS dan baja berlapis bubuk untuk penggunaan darurat, anestesi, perawatan, dan keperawatan bangsal. Pembeli menentukan tata letak laci, sistem kunci, paket aksesori, dan jenis troli berdasarkan departemen — dengan pasokan skala proyek, suku cadang standar, dan dokumentasi ekspor lengkap.
Troli Medis (juga disebut kereta medis atau kereta rumah sakit) adalah unit penyimpanan dan transportasi bergerak yang digunakan di rumah sakit, klinik, dan unit gawat darurat untuk membawa obat-obatan, instrumen, perlengkapan darurat, dan catatan pasien antar departemen. Sanyang Medical memproduksi troli plastik ABS, troli stainless steel, dan kereta darurat anestesi yang dilengkapi dengan roda diam, rem pengunci pusat, konfigurasi laci modular, dan permukaan tahan korosi, bersertifikat CE dan ISO 13485 untuk fasilitas kesehatan dan distributor peralatan medis di seluruh dunia.
Kesalahan pengadaan kereta medis biasanya berasal dari mencampuradukkan tujuan respons dan logika penyimpanan. Tabel ini memetakan setiap keluarga kereta ke departemen, model akses, dan konfigurasi standarnya — kerangka kerja yang sama yang digunakan tim ekspor kami saat menyiapkan penawaran distributor.
| Jenis Troli | Departemen Utama | Akses & Penguncian | Konfigurasi Standar | Prioritas Pembeli |
|---|---|---|---|---|
| Troli Darurat | Koridor UGD, ICU, OK | Segel pengaman bernomor — satu tarikan membuka semua laci | Rak defibrilator, papan CPR, tempat tabung O2, tiang infus, dudukan benda tajam | Kecepatan respons, tata letak obat standar, disiplin pemeriksaan segel |
| Troli Anestesi | Ruang Operasi | Kunci sentral; keypad/RFID opsional | 5-6 laci dangkal dengan grid pembagi halus untuk perlengkapan intubasi dan narkotika | Keamanan zat terkendali, penyortiran barang kecil yang presisi |
| Kereta Perawatan | Bangsal umum, ruang ganti | Kunci sentral | Laci dalam untuk cairan IV dan pembalut, tempat sampah, tempat jarum, keranjang samping | Kapasitas konsumabel, logika pengisian ulang, mudah dibersihkan |
| Kereta Keperawatan / Obat | Putaran bangsal, stasiun perawat | Kunci sentral per kelompok laci | Baki kaset obat, wadah berlabel pasien, tempat bagan, rak tulis | Efisiensi putaran harian, pencegahan kesalahan pengobatan |
| Troley Bayi / Kereta Bassinet | Maternitas, NICU | Keranjang tanpa kunci, dapat disesuaikan kemiringannya | Bassinet transparan, kemiringan Trendelenburg, rak penyimpanan bawah, rangka baja berlapis bubuk | Visibilitas bayi, stabilitas, roda diam di dekat bangsal |
Parameter inti untuk troli medis standar dan kereta darurat kami. Tata letak laci, warna, dan braket aksesori disesuaikan dengan kebutuhan departemen dan spesifikasi tender.
| Dimensi Standar (P x L x T) | Kira-kira 850 mm x 520 mm x 950 mm (tergantung jenis troli) |
|---|---|
| Bahan Badan Utama | Meja kerja ABS rekayasa kepadatan tinggi dengan tepi anti-tumpah yang terangkat; permukaan mulus dan tidak berpori |
| Rangka Struktural | Sasis baja berlapis bubuk dengan kolom aluminium alloy atau baja tahan karat |
| Konfigurasi Laci | 2 kecil, 2 sedang, 1 besar (standar) dengan kisi pemisah ABS modular; kedalaman campuran dapat dikonfigurasi per proyek |
| Rel Laci | Rel bantalan bola ekstensi penuh, penutupan lembut, dirancang untuk penggunaan bangsal siklus tinggi harian |
| Sistem Keamanan | Kunci sentral (troli perawat/perawatan) atau segel plastik lepas bernomor (troli darurat); keypad/RFID opsional |
| Roda | Roda kastor poliuretan tanpa suara 5 inci (2 dengan rem diagonal), anti-statis dan tahan terhadap kerontokan rambut |
| Aksesori Troli Darajat (Termasuk) | Rak defibrilator, papan CPR, tiang infus, tempat tabung oksigen, kotak jarum suntik, tempat sampah ganda |
| Kapasitas Beban | Kira-kira 100-150 kg beban dinamis total, tergantung model |
| Jumlah Pesanan Minimum (MOQ) | 10 Unit |
Kereta rumah sakit dibersihkan dengan disinfektan agresif beberapa kali per shift dan diharapkan dapat mempertahankan integritas struktural selama 5-10 tahun pemakaian. Oleh karena itu, pilihan material menentukan total biaya kepemilikan, bukan hanya harga beli. Kami menggabungkan tiga material secara sengaja:
Kereta darurat bergerak dari penyimpanan ke samping tempat tidur dalam hitungan detik, melewati ambang pintu, celah lift, dan lantai basah. Kegagalan mobilitas di tengah respons merupakan risiko klinis, sehingga kami memperlakukan roda dan rem sebagai komponen keselamatan, bukan perangkat keras komoditas.
Standar manajemen troli darurat rumah sakit modern — misalnya Standar Pengelolaan Troli Darurat di Rumah Sakit 2025 dari Otoritas Kesehatan Dubai (DHA/HRS/HPSD/ST-55) — memerlukan segel bukti gangguan, tata letak laci standar, dan pemeriksaan segel yang terdokumentasi. Sistem laci dan kunci kami dirancang berdasarkan disiplin ini.
From the high-stakes environment of the ER to the methodical pace of the general ward, we supply specialized carts optimized for specific clinical tasks — so distributors can quote one factory across a whole hospital project.
Crash carts arrive pre-configured with rotating defibrillator shelves, rear CPR backboards, and side-mounted oxygen cylinder brackets, ensuring all life-saving equipment is immediately accessible at the bedside.
Multiple shallow drawers with fine divider grids sort intubation kits and controlled substances precisely, secured by central key locks or optional RFID access systems for audit compliance.
Treatment and nursing carts carry medication cassettes, dressing supplies, waste bins, and sharps containers through daily rounds, with deep drawers sized for bulky IV fluid bags.
Distributors and EPC contractors rarely need a catalog-standard cart. We configure each order around your tender specification or local clinical protocol.
Choose the small/medium/large drawer mix, divider grid density, and internal cassette systems. We pre-assemble your layout per department and replicate it identically across the full fleet for consistent restocking.
Department color coding (for example red for emergency, blue for anesthesia) plus OEM logo placement for distributors building their own branded medical furniture line.
Central key lock, numbered breakaway seals, digital keypad, or RFID badge access — matched to your medication control and audit policy.
Defibrillator shelves, CPR boards, IV poles, oxygen cylinder holders, sharps brackets, waste bins, side baskets, chart holders, and writing shelves — mounted at the factory, not retrofitted on site.
ABS worktop with powder-coated steel chassis as standard; stainless steel columns or full stainless constructions available for high-humidity or sterile-core environments.
Multi-language user manuals, tender-format technical datasheets, and country-specific labeling support for registration and customs clearance.
We control the entire manufacturing process of our medical trolleys — from steel cutting and ABS injection molding to castor integration and final load testing — so fleet orders stay consistent across batches and years.
Medical furniture projects fail on consistency, not on unit price. Our production and parts system is built for buyers who reorder against the same specification for years.
We confirm drawer layout, accessories, color, and locking system on a signed configuration sheet before production starts.
For new project configurations, a pre-production sample or detailed photo/video set is approved by the buyer first.
Four-stage quality control runs against the locked specification, keeping every unit in the container identical.
Castors, dividers, locks, seals, and accessories stay reorderable by part code, so your installed fleet never becomes obsolete.
Our medical trolleys are manufactured under an ISO 13485 quality management system and supplied with the documentation packs importers need for local registration, tender bidding, and customs clearance — including CE marking documentation aligned with EU medical device requirements and apostilled certificates for cross-border use.
Menegaskan kepatuhan terhadap standar keselamatan dan kinerja perangkat medis Eropa.
Unduh PDFMensertifikasi sistem manajemen mutu komprehensif kami untuk pembuatan perangkat medis.
Unduh PDFDokumen penting untuk registrasi produk dan izin impor di banyak pasar internasional.
Unduh PDFTrolleys are bulky goods — freight damage and poor container utilization destroy project margins. Our export packing and loading process is designed for long sea routes and mixed-model orders.
Hospital buyers judge a trolley supplier on year five, not day one. Our after-sales system is built around standardized, replaceable components so your fleet stays serviceable for its full working life.
A selection of trolley configurations from our production range. Every model can be adapted in drawer layout, color, and accessory package for your market.
Clear answers to the configuration, compliance, and replenishment questions distributors and hospital buyers ask most often.
Ajukan Pertanyaan KhususA crash cart is built for code-blue response: numbered breakaway seal locks for instant drawer access, a defibrillator shelf, CPR backboard, oxygen cylinder holder, and a standardized drug layout that pharmacy can seal-check daily. A treatment cart is built for scheduled ward tasks such as dressing changes and medication rounds, using key-locked central locking, deeper storage drawers, waste bins, and sharps brackets instead of resuscitation hardware.
Ya. Semua troli medis kami menggunakan grid pemisah ABS modular di dalam setiap laci. Staf keperawatan dapat mengkonfigurasi ulang kompartemen untuk ampul, vial, dan jarum suntik tanpa alat, dan kami dapat mengkonfigurasi sebelumnya kombinasi kedalaman laci (kecil, sedang, besar) per proyek sebelum pengiriman.
Konfigurasi kereta darurat standar kami mencakup rak defibrilator berputar 360 derajat, papan CPR belakang, dudukan tabung oksigen yang dipasang di samping, tiang infus yang dapat disesuaikan, wadah jarum suntik, dua tempat sampah, dan sistem penguncian segel plastik terpusat yang dapat dilepas.
The body combines high-strength engineering ABS work surfaces with powder-coated steel and aluminum alloy columns. Surfaces are non-porous, seamless, and resistant to corrosion, impacts, and daily wipe-downs with alcohol- and chlorine-based hospital disinfectants.
Yes. Standard models use a central key lock or a numbered breakaway seal (crash carts). Optional upgrades include digital keypad locks and RFID badge-access systems for anesthesia carts storing narcotics that require strict audit trails.
Roda, pembagi laci, kunci, segel, dan braket aksesori telah distandarisasi di seluruh jajaran troli kami dan tetap diproduksi sebagai suku cadang yang dapat diganti. Distributor dan pembeli proyek dapat memesan ulang komponen yang cocok berdasarkan kode suku cadang bertahun-tahun setelah pengiriman armada asli, sehingga menjaga konsistensi armada campuran.
Jumlah pesanan minimum adalah 10 unit per model. Konfigurasi standar biasanya dikirim dalam waktu 25-35 hari setelah deposit dan konfirmasi gambar; tata letak laci, warna, atau sistem penguncian yang disesuaikan menambah sekitar 10-15 hari. Kami mendukung pemuatan kontainer model campuran untuk proyek rumah sakit.
A fully equipped emergency crash cart carries airway and breathing tools (laryngoscope, endotracheal tubes, bag-valve mask), cardiac drugs such as epinephrine and amiodarone, a defibrillator with paddles, IV supplies, gloves, and a sharps container — plus a CPR backboard and oxygen cylinder holder mounted on the cart body. Because survival from cardiac arrest falls roughly 7-10% for every minute defibrillation is delayed, standardized layouts and daily seal checks are essential.
Choose 125 mm (5-inch) polyurethane casters rated above the loaded cart weight — a 100-150 kg cart needs about 80 kg dynamic capacity per wheel. Specify diagonal brakes that lock both roll and swivel, sealed precision bearings, and anti-static, hair-resistant treads, so the trolley stays silent and stable in night wards and code-blue corridors.
Yes. As a hospital crash cart manufacturer in China and anesthesia cart manufacturer, Sanyang Medical provides full OEM/ODM service: custom drawer layouts, department color coding, logo placement, and locking systems, backed by CE and ISO 13485 documentation and 10+ years of export experience to 50+ countries. MOQ starts at 10 units per model. Learn more on our OEM/ODM localization solution halaman.
Factory-direct pricing depends on drawer count, body material (ABS versus stainless steel), locking system, and accessories such as defibrillator shelves and CPR boards. As an emergency crash cart supplier and ABS medical cart wholesale factory, we quote treatment trolley factory price per project rather than fixed list pricing — MOQ 10 units, with mixed-model container loading. Request a configured quote for exact pricing.
Medical trolleys are usually specified alongside beds and room infrastructure. Source the full ward package from one factory to keep quality, finish, and documentation consistent.
Manual and electric hospital beds for ICU, general ward, and home-care channels — the natural companion line for trolley fleet orders.
Lihat Tempat Tidur Rumah SakitBrowse the complete Sanyang Medical furniture range for ward, theatre, and emergency department sourcing.
Browse All ProductsFor EPC contractors and project buyers: bundled equipment packages with unified documentation, packing, and delivery schedules.
Jelajahi Solusi