We manufacture electric, electro-hydraulic, and mechanical operating tables for hospitals, distributors, and surgical project buyers who need stable positioning, radiolucent imaging access, and dependable long-term service. Configurations cover general surgery, orthopedics, gynecology, urology, and bariatric applications, with factory-direct documentation for tenders and registration.
Tables d'opération (also called surgical tables or OT tables — short for operation theatre tables) are motorized or hydraulic patient positioning platforms used in operating rooms to provide stable, adjustable support during surgical procedures. Sanyang Medical manufactures electric and electro-hydraulic operating tables with safe working loads up to 300 kg, radiolucent C-arm compatible tabletops, and CE/ISO 13485 certified quality for hospital procurement teams and medical equipment distributors worldwide.
Programmable memory positioning
High load capacity & rigidity
Ergonomic delivery support
Longitudinal sliding & radiolucent
Up to 300kg safe working load
Global demand for surgical operating tables continues to grow at roughly 6% per year, driven by hybrid OR construction and bariatric case volumes. The right drive system depends on your procedure mix, imaging intensity, and in-house maintenance capability — this comparison is how we advise distributors to position each series.
| Series | Drive System | Charge de travail sécuritaire | Positioning Control | Maintenance Profile | Best Fit |
|---|---|---|---|---|---|
| Electric (Electromechanical) | Low-voltage DC linear actuators with hand pendant | Jusqu'à 250 kg | Programmable memory positions, one-touch level reset | No hydraulic oil; actuator and battery checks only | General surgery High-throughput ORs, day-surgery centers |
| Electro-Hydraulic | Electric pump driving sealed hydraulic cylinders | Up to 300 kg | Smoothest, jitter-free articulation under full load | Sealed circuit; annual pressure-hold inspection | Complex & bariatric Orthopedics, trauma, hybrid OR imaging |
| Mechanical (Manual-Hydraulic) | Foot-pump hydraulics with gear-driven sections | Up to 200 kg | Manual cranks and levers; no power dependency | Simplest service; minimal spare-parts needs | Budget projects Rural hospitals, backup rooms, tender entry lines |
| Obstetric & Specialty | Electric or manual, procedure-specific layout | Up to 200 kg | Rapid conversion between exam, delivery, and procedure positions | Matched to base drive type | Maternity & gyne LDR rooms, gynecology and urology clinics |
Core parameters for our standard operating room table configurations. Specialized orthopedic, imaging, and bariatric modifications are available on request — share your tender schedule and we will map each line item.
| Charge de travail sécuritaire | Up to 300 kg (660 lbs) on heavy-duty electro-hydraulic models; 250 kg electric; 200 kg mechanical |
|---|---|
| Table Dimensions (L x W) | Approx. 2000 mm x 500 mm (accessory rails along full length) |
| Plage d'altitude | 700 mm – 1000 mm, electrically or hydraulically adjustable; low position supports seated surgeon work |
| Trendelenburg / Reverse | ± 25° under rated load |
| Inclinaison latérale (gauche/droite) | ± 15° |
| Back / Leg Section | Back up ≥ 70°, down ≥ 15°; split leg plates adjustable independently |
| Compatibilité avec l'arceau en C | Radiolucent tabletop panels with longitudinal sliding up to 300 mm for full-length imaging windows |
| Control & Safety | Hand pendant plus column override panel; position locks prevent unintended movement |
| Niveau de bruit | ≤ 50 dB during electro-hydraulic actuation |
| Power Supply & Backup | 110-240 V, 50/60 Hz with built-in battery supporting 50-80 articulation cycles |
| Base de conformité | Designed and tested in alignment with IEC 60601-1 and IEC 60601-2-46 (operating tables); manufactured under ISO 13485 |
| Quantité minimale de commande (QMC) | 10 Unités per model, mixed-model container loading supported |
Three engineering decisions determine whether an operating table earns its place in a modern OR. Here is exactly how we build each one — with the parameters your biomedical team will verify.
High-transmittance tabletop panels keep attenuation low for clear fluoroscopy at standard dose settings. The full top slides up to 300 mm longitudinally, so the C-arm gantry reaches head-to-pelvis imaging zones without moving the anesthetized patient — a decisive factor in orthopedic trauma and ERCP workflows.
Reinforced steel columns and high-density cylinders hold rated load through full Trendelenburg and lateral tilt without drift. Every hydraulic circuit is pressure-hold tested and full-stroke cycled before packing, backing our zero-leakage commitment — the failure mode hospital buyers flag most often in tender evaluations.
Tables are engineered and tested in alignment with IEC 60601-1 general electrical safety and IEC 60601-2-46 particular requirements for operating tables — covering stability, load-bearing, and protection against unintended movement. Primary hand pendant, column override panel, and battery backup provide three independent layers of control.
Specialty configuration is where procurement projects succeed or fail. These are the four scenario packages we configure most often for hospital and distributor orders.
Fast level reset, steep Trendelenburg for laparoscopic access, and memory positions that cut turnover time between cases in high-throughput theaters.
Radiolucent imaging window plus traction-frame compatibility via standard side rails supports hip, femoral, and tibial nailing under continuous fluoroscopy.
Purpose-built delivery and examination beds with ergonomic leg supports, integrated fluid collection, and rapid conversion between labor, delivery, and procedure modes.
300 kg safe working load with full articulation retained under load — no manual re-blocking, no positioning compromises during long bariatric procedures.
Hospitals cannot afford equipment failure mid-surgery. Our operating tables are built on redundant safety systems and fluid-resistant architectures to ensure continuous operation across a 10-year service life.
From robust general surgery platforms to specialized obstetric beds, we manufacture the right foundation for your clinical needs — and pre-configure accessories before shipment so rooms go live faster.
The standard for modern surgical suites: smooth electromechanical positioning, programmable memory for frequent postures, and one-touch zero-leveling. No hydraulic oil means the lightest routine maintenance in the lineup.
Foot-pump hydraulics and gear-driven sections deliver full positioning without mains power — the proven choice for budget tenders, rural facilities, and backup rooms where service infrastructure is limited.
Purpose-built delivery and gynecological tables with ergonomic leg supports, fluid collection basins, and rapid-release mechanisms that support dynamic LDR and minor-procedure workflows.
Every table ships with standard stainless-steel side rails along the full tabletop length, so third-party and proprietary accessories fit without adapters. Distributors can also order under OEM/ODM terms with localized branding and documentation.
We control the full process in-house — steel cutting, robotic welding, hydraulic assembly, electrical integration, and final test — so the table you approve as a sample is the table that ships in bulk. Every unit leaves with its own load-test and cycling record.
Sanyang Medical has manufactured operating tables and complete OR equipment at its 15,000 m² factory in Qufu, Shandong since 2015. A 100+ person team covers R&D, welding, assembly, testing, and export support, serving distributors and hospital projects across North America, Europe, Africa, the Middle East, and Southeast Asia.
Operating tables are manufactured under an ISO 13485 quality management system and engineered in alignment with IEC 60601-1 and IEC 60601-2-46 safety requirements. We supply complete documentation packs — certificates, test reports, declarations, and apostilled legalizations — to support local registration, tender bidding, and customs clearance.
Confirme la conformité aux normes européennes de sécurité et de performance des dispositifs médicaux.
Télécharger le PDFCertifie notre système de gestion de la qualité complet pour la fabrication de dispositifs médicaux.
Télécharger le PDFDocument essentiel pour l'enregistrement du produit et le dédouanement dans de nombreux marchés internationaux.
Télécharger le PDFProject timelines matter as much as specifications. Our export team plans production and freight around your commissioning date, and consolidates operating tables with lights, pendants, and beds in mixed containers to cut landed cost.
Distributors win repeat business on service, not on first price. We structure after-sales so your local team can maintain tables confidently without factory escort for every issue.
Straight answers on imaging compatibility, drive-system selection, leakage risk, sample consistency, and commercial terms.
Posez une question personnaliséeOui. Nos tables d'opération utilisent des plateaux radiotransparents et un plateau coulissant longitudinal avec une course allant jusqu'à 300 mm, créant une large fenêtre d'imagerie sans métal. Cela prend en charge la fluoroscopie en bras en C dans les procédures orthopédiques, traumatologiques, urologiques et cardiovasculaires sans repositionner le patient.
Nos modèles électriques et électro-hydrauliques robustes sont conçus avec des colonnes de levage renforcées et des vérins hydrauliques à haute densité, supportant une charge de travail sûre allant jusqu'à 300 kg (660 lb) sur toute la plage d'articulation, y compris le Trendelenburg et l'inclinaison latérale.
Les tables électro-hydrauliques offrent l'articulation la plus douce et la plus silencieuse ainsi que la capacité de charge la plus élevée, convenant aux chirurgies complexes et bariatriques.
Les circuits hydrauliques sont assemblés avec des groupes de pompes scellés et des flexibles homologués haute pression, puis vérifiés par des tests de maintien de pression et de cycles complets sur chaque unité avant l'emballage. Notre engagement zéro fuite signifie que toute table présentant des suintements pendant la période de garantie est réparée ou remplacée dans le cadre de notre garantie qualité.
Toutes les tables d'opération électriques et électro-hydrauliques incluent une batterie de secours intégrée de grande capacité qui se met automatiquement en marche en cas de panne de courant, pouvant prendre en charge environ 50 à 80 cycles d'articulation complets afin que les interventions puissent être terminées en toute sécurité. Une commande manuelle de dérogation sur la colonne constitue un second niveau de redondance.
Oui. Les tables sont équipées de rampes latérales standard en acier inoxydable compatibles avec une large gamme d'accessoires modulaires, notamment des cadres de traction orthopédique, des porte-jambes, des supports de bras, des écrans d'anesthésie et des positionneurs de tête. Des ensembles spécialisés pour l'orthopédie, la gynécologie et l'urologie peuvent être configurés avant l'expédition.
Nous verrouillons un échantillon de référence et un dossier technique lors de la confirmation de commande. La production de masse suit la même nomenclature, les mêmes gabarits de soudure et le même protocole de test, et chaque lot passe par des inspections à la réception, en cours de fabrication et avant expédition, avec des tests de charge et de cyclage enregistrés par unité. Une inspection pré-expédition par un tiers est la bienvenue.
La commande minimale standard est de 10 unités par modèle, avec possibilité de chargement de conteneur multi-modèles. Le délai de production habituel est de 25 à 35 jours après le dépôt et la confirmation des spécifications.
Electric operating tables use low-voltage DC linear actuators with programmable memory positions and oil-free maintenance, rated to 250 kg. Hydraulic (electro-hydraulic) tables drive sealed cylinders for smoother, quieter articulation under loads up to 300 kg, making them the standard for orthopedic, bariatric, and C-arm imaging cases. Our electric vs. hydraulic comparison guide covers selection in detail.
Surgical table (OT table) pricing is driven by drive system, safe working load, C-arm radiolucency, and specialty accessories. Mechanical foot-pump tables are the lowest-cost entry point, electric models sit mid-range, and electro-hydraulic C-arm compatible configurations with orthopedic traction frames carry the highest price. As a factory-direct operating table manufacturer, we quote per configuration — send your tender BOQ for pricing.
A C-arm compatible operating table lets a mobile C-arm X-ray unit image the patient without obstruction. It combines radiolucent (X-ray transparent) tabletop panels, a longitudinal sliding top — up to 300 mm on our models — and an open C-shaped base so the gantry can orbit from head to pelvis. This is essential for orthopedic trauma, urology, and cardiovascular fluoroscopy.
Safe working load (SWL) is the maximum patient-plus-accessory weight an operating table can hold through full articulation, including Trendelenburg tilt. Standard electric tables are rated around 200–250 kg, while heavy-duty electro-hydraulic models reach 300 kg (660 lbs) for bariatric surgery. Every Sanyang table is load-tested at rated capacity before shipment, with the test record included in the export documentation.
Yes. As an orthopedic operating table manufacturer, we configure electric and electro-hydraulic tables with traction frames, boot stirrups, sacral supports, and counter-traction posts for hip, femoral, and tibial nailing. Radiolucent tabletops support continuous C-arm fluoroscopy, and each orthopedic package ships pre-assembled with the table, backed by long-term spare-parts supply.
Operating tables are usually procured as part of a wider theater package. These categories ship from the same factory and consolidate into one container and one document set.
Send your tender schedule, target configuration, or a photo of your current room. Our export engineers will reply with a matched model proposal, C-arm compatibility confirmation, accessory list, and container-loading plan.