Sanyang Medical manufactures electric, electro-hydraulic, and mechanical operating tables for general surgery, orthopedics, gynecology, urology, and bariatric applications, supplied factory-direct to hospitals, distributors, and project buyers with tender and registration documentation.
Mesas de operaciones (also called surgical tables or OT tables, short for operation theatre tables) are motorized or hydraulic platforms for stable surgical patient positioning. Sanyang Medical builds them with 300 kg safe working loads, radiolucent C-arm compatible tabletops, and CE/ISO 13485 certified quality for hospital procurement teams worldwide.
Posicionamiento programable con memoria
Alta capacidad de carga y rigidez
Soporte ergonómico para el parto
Deslizamiento longitudinal y radiolúcido
Hasta 300 kg de carga de trabajo segura
Global demand for surgical operating tables continues to grow at roughly 6% per year, driven by hybrid OR construction and bariatric case volumes. The right drive system depends on your procedure mix, imaging intensity, and in-house maintenance capability. This comparison is how we advise distributors to position each series.
| Series | Sistema de accionamiento | Carga de trabajo segura | Control de posicionamiento | Perfil de mantenimiento | Mejor ajuste |
|---|---|---|---|---|---|
| Eléctrico (electromecánico) | Actuadores lineales de CC de bajo voltaje con mando colgante | Hasta 250 kg | Posiciones de memoria programables, restablecimiento de nivel con un solo toque | Sin aceite hidráulico; solo comprobaciones de actuadores y batería | Cirugía general Quirófanos de alto rendimiento, centros de cirugía ambulatoria |
| Electrohidráulica | Bomba eléctrica que acciona cilindros hidráulicos sellados | Hasta 300 kg | Articulación más suave y sin vibraciones a plena carga | Circuito sellado; inspección anual de retención de presión | Complejo y bariátrico Ortopedia, traumatología, imagenología para quirófano híbrido |
| Mecánico (Manual-Hidráulico) | Hidráulica con bomba de pedal y secciones accionadas por engranajes | Hasta 200 kg | Manivelas y palancas manuales; sin dependencia de energía eléctrica | Servicio más sencillo; necesidades mínimas de repuestos | Proyectos de presupuesto limitado Hospitales rurales, salas de respaldo, líneas de entrada a licitaciones |
| Obstétrico y Especialidades | Eléctrico o manual, distribución específica para procedimientos | Hasta 200 kg | Conversión rápida entre posiciones de examen, parto y procedimiento | Adaptado al tipo de accionamiento base | Maternidad y ginecología Salas LDR, clínicas de ginecología y urología |
Core parameters for our standard operating room table configurations. Specialized orthopedic, imaging, and bariatric modifications are available on request. Share your tender schedule and we will map each line item.
| Carga de trabajo segura | Hasta 300 kg (660 lb) en modelos electrohidráulicos de servicio pesado; 250 kg eléctricos; 200 kg mecánicos |
|---|---|
| Dimensiones de la mesa (L x A) | Aprox. 2000 mm x 500 mm (rieles accesorios a lo largo de toda la extensión) |
| Rango de elevación | 700 mm – 1000 mm, ajustable eléctrica o hidráulicamente; la posición baja favorece el trabajo del cirujano sentado |
| Trendelenburg / Inversa | ± 25° bajo carga nominal |
| Inclinación lateral (izquierda/derecha) | ± 15° |
| Sección dorsal / de piernas | Dorso hacia arriba ≥ 70°, hacia abajo ≥ 15°; placas de piernas divididas ajustables de forma independiente |
| Compatibilidad con el brazo en C | Paneles de superficie radiolúcida con deslizamiento longitudinal de hasta 300 mm para ventanas de imagen de longitud completa |
| Control y seguridad | Mando manual colgante más panel de anulación en la columna; los bloqueos de posición evitan movimientos no intencionados |
| Nivel de ruido | ≤ 50 dB durante la activación electrohidráulica |
| Suministro eléctrico y respaldo | 110-240 V, 50/60 Hz con batería integrada que admite 50-80 ciclos de articulación |
| Base de Cumplimiento | Diseñado y probado conforme a IEC 60601-1 e IEC 60601-2-46 (mesas de operaciones); fabricado bajo ISO 13485 |
| Cantidad mínima de pedido (MOQ) | 10 Unidades por modelo, se admite carga de contenedor con modelos mixtos |
Three engineering decisions determine whether an operating table earns its place in a modern OR. Here is exactly how we build each one, with the parameters your biomedical team will verify.
High-transmittance tabletop panels keep attenuation low for clear fluoroscopy at standard dose settings. The full top slides up to 300 mm longitudinally, so the C-arm gantry reaches head-to-pelvis imaging zones without moving the anesthetized patient, a decisive factor in orthopedic trauma and ERCP workflows.
Reinforced steel columns and high-density cylinders hold rated load through full Trendelenburg and lateral tilt without drift. Every hydraulic circuit is pressure-hold tested and full-stroke cycled before packing, backing our zero-leakage commitment, the failure mode hospital buyers flag most often in tender evaluations.
Tables are engineered and tested in alignment with IEC 60601-1 general electrical safety and IEC 60601-2-46 particular requirements for operating tables, covering stability, load-bearing, and protection against unintended movement. Primary hand pendant, column override panel, and battery backup provide three independent layers of control.
La configuración especializada es donde los proyectos de adquisición tienen éxito o fracasan. Estos son los cuatro paquetes de escenarios que configuramos con más frecuencia para pedidos de hospitales y distribuidores.
Restablecimiento rápido del nivel, Trendelenburg pronunciado para acceso laparoscópico y posiciones de memoria que reducen el tiempo de preparación entre casos en quirófanos de alto rendimiento.
Ventana de imagen radiolúcida más compatibilidad con marcos de tracción a través de rieles laterales estándar, lo que permite la fijación de cadera, fémur y tibia bajo fluoroscopia continua.
Camas de parto y exploración diseñadas específicamente con soportes ergonómicos para piernas, recogida de fluidos integrada y conversión rápida entre modos de trabajo de parto, parto y procedimiento.
300 kg safe working load with full articulation retained under load: no manual re-blocking, no positioning compromises during long bariatric procedures.
Los hospitales no pueden permitirse fallos de equipamiento a mitad de una cirugía. Nuestras mesas de operaciones se basan en sistemas de seguridad redundantes y arquitecturas resistentes a fluidos para garantizar un funcionamiento continuo a lo largo de una vida útil de 10 años.
From general surgery platforms to specialized obstetric beds, we manufacture the right foundation for your clinical needs, and we pre-configure accessories before shipment so rooms go live faster.
El estándar para suites quirúrgicas modernas: posicionamiento electromecánico suave, memoria programable para posturas frecuentes y nivelación a cero con un solo toque. Sin aceite hidráulico significa el mantenimiento rutinario más ligero de la línea.
Foot-pump hydraulics and gear-driven sections deliver full positioning without mains power, the proven choice for budget tenders, rural facilities, and backup rooms where service infrastructure is limited.
Mesas de parto y ginecológicas diseñadas específicamente con soportes ergonómicos para piernas, recipientes de recolección de fluidos y mecanismos de liberación rápida que respaldan los flujos de trabajo dinámicos de LDR y procedimientos menores.
Toda mesa se envía con rieles laterales estándar de acero inoxidable a lo largo de toda la superficie de la mesa, de modo que los accesorios de terceros y propietarios se ajustan sin adaptadores. Los distribuidores también pueden realizar pedidos en términos OEM/ODM con marca y documentación localizadas.
We control the full process in-house: steel cutting, robotic welding, hydraulic assembly, electrical integration, and final test. The table you approve as a sample is the table that ships in bulk. Every unit leaves with its own load-test and cycling record.
Sanyang Medical ha fabricado mesas de operaciones y equipos completos de quirófano en su fábrica de 15.000 m² en Qufu, Shandong, desde 2015. Un equipo de más de 100 personas cubre I+D, soldadura, ensamblaje, pruebas y soporte de exportación, sirviendo a distribuidores y proyectos hospitalarios en América del Norte, Europa, África, Oriente Medio y el Sudeste Asiático.
Operating tables are manufactured under an ISO 13485 quality management system and engineered in alignment with IEC 60601-1 and IEC 60601-2-46 safety requirements. We supply complete documentation packs, including certificates, test reports, declarations, and apostilled legalizations, to support local registration, tender bidding, and customs clearance.
Confirma el cumplimiento de los estándares europeos de seguridad y rendimiento de dispositivos médicos.
Descargar PDFCertifica nuestro sistema integral de gestión de calidad para la fabricación de dispositivos médicos.
Descargar PDFDocumento esencial para el registro de productos y el despacho de importación en muchos mercados internacionales.
Descargar PDFLos plazos del proyecto importan tanto como las especificaciones. Nuestro equipo de exportación planifica la producción y el flete en torno a su fecha de puesta en marcha, y consolida mesas de operaciones con luces, columnas y camas en contenedores mixtos para reducir el costo de importación.
Los distribuidores ganan negocios recurrentes gracias al servicio, no al precio inicial. Estructuramos el servicio posventa para que su equipo local pueda mantener las mesas con confianza sin necesidad de asistencia de fábrica para cada problema.
Respuestas directas sobre compatibilidad con imagenología, selección del sistema de accionamiento, riesgo de fugas, consistencia de muestras y condiciones comerciales.
Haga una pregunta personalizadaSí. Nuestras mesas de operaciones utilizan paneles radiotransparentes y una superficie deslizante longitudinal con hasta 300 mm de recorrido, creando una amplia ventana de imagen libre de metal. Esto facilita la fluoroscopia con arco en C en procedimientos ortopédicos, traumatológicos, urológicos y cardiovasculares sin necesidad de reposicionar al paciente.
Nuestros modelos eléctricos y electrohidráulicos de servicio pesado están diseñados con columnas de elevación reforzadas y cilindros hidráulicos de alta densidad, soportando una carga de trabajo segura de hasta 300 kg (660 lbs) en todo el rango de articulación, incluyendo inclinación Trendelenburg y lateral.
Las mesas electrohidráulicas ofrecen la articulación más suave y silenciosa y la mayor capacidad de carga, adecuadas para cirugías complejas y bariátricas.
Los circuitos hidráulicos se ensamblan con unidades de bomba selladas y mangueras de alta presión, y se verifican mediante pruebas de mantenimiento de presión y ciclos completos en cada unidad antes del embalaje. Nuestro compromiso de cero fugas significa que cualquier mesa que presente filtraciones durante el período de garantía será reparada o reemplazada bajo nuestra garantía de calidad.
Todas las mesas de operaciones eléctricas y electrohidráulicas incluyen una batería de respaldo de alta capacidad incorporada que se activa automáticamente en caso de fallo eléctrico, soportando aproximadamente de 50 a 80 ciclos completos de articulación para que los procedimientos puedan completarse de manera segura. Un control de anulación manual en la columna proporciona una segunda capa de redundancia.
Sí. Las mesas están equipadas con rieles laterales estándar de acero inoxidable compatibles con una amplia gama de accesorios modulares, que incluyen marcos de tracción ortopédica, soportes para piernas, mesas para brazos, pantallas de anestesia y posicionadores de cabeza. Los paquetes especializados para ortopedia, ginecología y urología se pueden configurar antes del envío.
Bloqueamos una muestra dorada y un expediente técnico en la confirmación del pedido. La producción en masa sigue la misma lista de materiales, dispositivos de soldadura y protocolo de prueba, y cada lote pasa inspecciones de entrada, en proceso y previas al envío, con pruebas de carga y ciclos registradas por unidad. La inspección previa al envío por terceros es bienvenida.
El MOQ estándar es de 10 unidades por modelo, con posibilidad de carga en contenedor de modelos mixtos. El plazo de producción típico es de 25 a 35 días después del depósito y la confirmación de las especificaciones. Toda mesa de operaciones tiene una garantía de al menos 12 meses desde la entrega, respaldada por suministro de repuestos de por vida y soporte técnico remoto.
Las mesas de operaciones eléctricas utilizan actuadores lineales de CC de bajo voltaje con posiciones de memoria programables y mantenimiento sin aceite, clasificadas para 250 kg. Las mesas hidráulicas (electrohidráulicas) accionan cilindros sellados para una articulación más suave y silenciosa bajo cargas de hasta 300 kg, lo que las convierte en el estándar para casos de ortopedia, bariátrica e imagenología con arco en C. Nuestra guía de comparación entre eléctricas e hidráulicas cubre la selección en detalle.
Surgical table (OT table) pricing is driven by drive system, safe working load, C-arm radiolucency, and specialty accessories. Mechanical foot-pump tables are the lowest-cost entry point, electric models sit mid-range, and electro-hydraulic C-arm compatible configurations with orthopedic traction frames carry the highest price. As a factory-direct operating table manufacturer, we quote per configuration: envíe su BOQ de licitación para obtener precios.
A C-arm compatible operating table lets a mobile C-arm X-ray unit image the patient without obstruction. It combines radiolucent (X-ray transparent) tabletop panels, a longitudinal sliding top (up to 300 mm on our models) and an open C-shaped base so the gantry can orbit from head to pelvis. This is essential for orthopedic trauma, urology, and cardiovascular fluoroscopy.
La capacidad de carga de trabajo segura (SWL) es el peso máximo de paciente más accesorios que una mesa de operaciones puede soportar durante toda su articulación, incluida la inclinación de Trendelenburg. Las mesas eléctricas estándar están clasificadas alrededor de 200–250 kg, mientras que los modelos electrohidráulicos de servicio pesado alcanzan 300 kg (660 lbs) para cirugía bariátrica. Cada mesa Sanyang se somete a pruebas de carga a su capacidad nominal antes del envío, y el registro de la prueba se incluye en la documentación de exportación.
Sí. Como fabricante de mesas de operaciones ortopédicas, configuramos mesas eléctricas y electrohidráulicas con marcos de tracción, estribos tipo bota, soportes sacros y postes de contratracción para enclavado de cadera, femoral y tibial. Las superficies radiotransparentes permiten fluoroscopia continua con arco en C, y cada paquete ortopédico se envía preensamblado con la mesa, respaldado por suministro de repuestos a largo plazo. suministro de repuestos.
Las mesas de operaciones generalmente se adquieren como parte de un paquete integral de quirófano. Estas categorías se envían desde la misma fábrica y se consolidan en un solo contenedor y un solo conjunto de documentos.
Send your tender schedule, target configuration, or a photo of your current room. Our export engineers will reply with a matched model proposal, C-arm compatibility confirmation, accessory list, and container-loading plan.