Sanyang Medical manufactures electric, electro-hydraulic, and mechanical operating tables for general surgery, orthopedics, gynecology, urology, and bariatric applications, supplied factory-direct to hospitals, distributors, and project buyers with tender and registration documentation.
Meja Operasi (also called surgical tables or OT tables, short for operation theatre tables) are motorized or hydraulic platforms for stable surgical patient positioning. Sanyang Medical builds them with 300 kg safe working loads, radiolucent C-arm compatible tabletops, and CE/ISO 13485 certified quality for hospital procurement teams worldwide.
Posisi memori yang dapat diprogram
Kapasitas beban tinggi & kekakuan
Dukungan persalinan ergonomis
Geser memanjang & radiolusen
Beban kerja aman hingga 300kg
Global demand for surgical operating tables continues to grow at roughly 6% per year, driven by hybrid OR construction and bariatric case volumes. The right drive system depends on your procedure mix, imaging intensity, and in-house maintenance capability. This comparison is how we advise distributors to position each series.
| Seri | Sistem Penggerak | Beban Kerja Aman | Kontrol Posisi | Profil Pemeliharaan | Kesesuaian Terbaik |
|---|---|---|---|---|---|
| Listrik (Elektromekanis) | Aktuator linier DC tegangan rendah dengan gantungan tangan | Hingga 250 kg | Posisi memori yang dapat diprogram, reset level satu sentuhan | Tanpa oli hidraulik; hanya pemeriksaan aktuator dan baterai | Bedah umum OR berkapasitas tinggi, pusat bedah harian |
| Elektro-Hidraulik | Pompa listrik menggerakkan silinder hidraulik tertutup | Hingga 300 kg | Artikulasi paling halus dan bebas getaran pada beban penuh | Sirkuit tertutup; inspeksi penahan tekanan tahunan | Kompleks & bariatrik Ortopedi, trauma, pencitraan OR hibrida |
| Mekanis (Manual-Hidraulik) | Hidraulik pompa kaki dengan bagian berpenggerak roda gigi | Hingga 200 kg | Engkol dan tuas manual; tidak bergantung pada daya listrik | Perawatan paling sederhana; kebutuhan suku cadang minimal | Proyek anggaran terbatas Rumah sakit pedesaan, ruang cadangan, lini tender |
| Obstetri & Spesialis | Listrik atau manual, tata letak khusus prosedur | Hingga 200 kg | Konversi cepat antara posisi pemeriksaan, persalinan, dan prosedur | Sesuai dengan tipe penggerak dasar | Maternitas & ginekologi Ruang LDR, klinik ginekologi dan urologi |
Core parameters for our standard operating room table configurations. Specialized orthopedic, imaging, and bariatric modifications are available on request. Share your tender schedule and we will map each line item.
| Beban Kerja Aman | Hingga 300 kg (660 lbs) pada model elektro-hidraulik tugas berat; 250 kg listrik; 200 kg mekanis |
|---|---|
| Dimensi Meja (P x L) | Kira-kira 2000 mm x 500 mm (rel aksesori di sepanjang panjang penuh) |
| Rentang Elevasi | 700 mm – 1000 mm, dapat disesuaikan secara listrik atau hidraulik; posisi rendah mendukung pekerjaan ahli bedah yang duduk |
| Trendelenburg / Terbalik | ± 25° di bawah beban terukur |
| Kemiringan Lateral (Kiri/Kanan) | ± 15° |
| Bagian Punggung / Kaki | Punggung naik ≥ 70°, turun ≥ 15°; pelat kaki terpisah dapat disesuaikan secara independen |
| Kompatibilitas C-Arm | Panel meja radiolusen dengan geser memanjang hingga 300 mm untuk jendela pencitraan panjang penuh |
| Kontrol & Keselamatan | Pendant tangan plus panel override kolom; kunci posisi mencegah gerakan yang tidak diinginkan |
| Tingkat Kebisingan | ≤ 50 dB selama aktuasi elektro-hidraulik |
| Catu Daya & Cadangan | 110-240 V, 50/60 Hz dengan baterai internal yang mendukung 50-80 siklus artikulasi |
| Dasar Kepatuhan | Dirancang dan diuji sesuai dengan IEC 60601-1 dan IEC 60601-2-46 (meja operasi); diproduksi di bawah ISO 13485 |
| Jumlah Pesanan Minimum (MOQ) | 10 Unit per model, dukungan pemuatan kontainer model campuran |
Three engineering decisions determine whether an operating table earns its place in a modern OR. Here is exactly how we build each one, with the parameters your biomedical team will verify.
High-transmittance tabletop panels keep attenuation low for clear fluoroscopy at standard dose settings. The full top slides up to 300 mm longitudinally, so the C-arm gantry reaches head-to-pelvis imaging zones without moving the anesthetized patient, a decisive factor in orthopedic trauma and ERCP workflows.
Reinforced steel columns and high-density cylinders hold rated load through full Trendelenburg and lateral tilt without drift. Every hydraulic circuit is pressure-hold tested and full-stroke cycled before packing, backing our zero-leakage commitment, the failure mode hospital buyers flag most often in tender evaluations.
Tables are engineered and tested in alignment with IEC 60601-1 general electrical safety and IEC 60601-2-46 particular requirements for operating tables, covering stability, load-bearing, and protection against unintended movement. Primary hand pendant, column override panel, and battery backup provide three independent layers of control.
Konfigurasi khusus adalah tempat proyek pengadaan berhasil atau gagal. Ini adalah empat paket skenario yang paling sering kami konfigurasikan untuk pesanan rumah sakit dan distributor.
Reset level cepat, Trendelenburg curam untuk akses laparoskopi, dan posisi memori yang memangkas waktu pergantian antar kasus di ruang operasi berkapasitas tinggi.
Jendela pencitraan radiolusen plus kompatibilitas rangka traksi melalui rel samping standar mendukung penempatan paku paha, femoral, dan tibialis di bawah fluoroskopi berkelanjutan.
Tempat tidur persalinan dan pemeriksaan yang dirancang khusus dengan penyangga kaki ergonomis, penampung cairan terintegrasi, dan konversi cepat antara mode persalinan, melahirkan, dan prosedur.
300 kg safe working load with full articulation retained under load: no manual re-blocking, no positioning compromises during long bariatric procedures.
Rumah sakit tidak dapat menanggung kegagalan peralatan di tengah operasi. Meja operasi kami dibangun di atas sistem keselamatan redundan dan arsitektur tahan cairan untuk memastikan operasi berkelanjutan selama masa pakai 10 tahun.
From general surgery platforms to specialized obstetric beds, we manufacture the right foundation for your clinical needs, and we pre-configure accessories before shipment so rooms go live faster.
The standard for modern surgical suites: smooth electromechanical positioning, programmable memory for frequent postures, and one-touch zero-leveling. No hydraulic oil means the lightest routine maintenance in the lineup.
Foot-pump hydraulics and gear-driven sections deliver full positioning without mains power, the proven choice for budget tenders, rural facilities, and backup rooms where service infrastructure is limited.
Purpose-built delivery and gynecological tables with ergonomic leg supports, fluid collection basins, and rapid-release mechanisms that support dynamic LDR and minor-procedure workflows.
Every table ships with standard stainless-steel side rails along the full tabletop length, so third-party and proprietary accessories fit without adapters. Distributors can also order under OEM/ODM terms with localized branding and documentation.
We control the full process in-house: steel cutting, robotic welding, hydraulic assembly, electrical integration, and final test. The table you approve as a sample is the table that ships in bulk. Every unit leaves with its own load-test and cycling record.
Sanyang Medical has manufactured operating tables and complete OR equipment at its 15,000 m² factory in Qufu, Shandong since 2015. A 100+ person team covers R&D, welding, assembly, testing, and export support, serving distributors and hospital projects across North America, Europe, Africa, the Middle East, and Southeast Asia.
Operating tables are manufactured under an ISO 13485 quality management system and engineered in alignment with IEC 60601-1 and IEC 60601-2-46 safety requirements. We supply complete documentation packs, including certificates, test reports, declarations, and apostilled legalizations, to support local registration, tender bidding, and customs clearance.
Menegaskan kepatuhan terhadap standar keselamatan dan kinerja perangkat medis Eropa.
Unduh PDFMensertifikasi sistem manajemen mutu komprehensif kami untuk pembuatan perangkat medis.
Unduh PDFDokumen penting untuk registrasi produk dan izin impor di banyak pasar internasional.
Unduh PDFProject timelines matter as much as specifications. Our export team plans production and freight around your commissioning date, and consolidates operating tables with lights, pendants, and beds in mixed containers to cut landed cost.
Distributors win repeat business on service, not on first price. We structure after-sales so your local team can maintain tables confidently without factory escort for every issue.
Straight answers on imaging compatibility, drive-system selection, leakage risk, sample consistency, and commercial terms.
Ajukan Pertanyaan KhususYa. Meja operasi kami menggunakan panel meja radiolusen dan bagian atas geser memanjang dengan jarak tempuh hingga 300 mm, menciptakan jendela pencitraan bebas logam yang lebar. Ini mendukung fluoroskopi lengan-C dalam prosedur ortopedi, trauma, urologi, dan kardiovaskular tanpa memposisikan ulang pasien.
Model listrik dan elektro-hidraulik tugas berat kami dirancang dengan kolom pengangkat yang diperkuat dan silinder hidraulik kepadatan tinggi, mendukung beban kerja aman hingga 300 kg (660 lbs) di seluruh rentang artikulasi penuh, termasuk Trendelenburg dan kemiringan lateral.
Meja elektro-hidrolik memberikan artikulasi paling halus dan tenang serta kapasitas beban tertinggi, cocok untuk operasi kompleks dan bariatrik. Meja listrik (elektromekanis) menawarkan posisi memori yang dapat diprogram dan perawatan rutin yang lebih rendah. Meja mekanis merupakan opsi masuk yang berorientasi anggaran untuk fasilitas dengan kebutuhan posisi dasar dan infrastruktur servis terbatas. Kami merekomendasikan untuk menyesuaikan sistem penggerak dengan kompleksitas prosedur, permintaan pencitraan, dan kemampuan pemeliharaan biomedis Anda.
Rangkaian hidrolik dirakit dengan unit pompa tertutup dan selang bertekanan tinggi, kemudian diverifikasi dengan uji penahan tekanan dan siklus langkah penuh pada setiap unit sebelum dikemas. Komitmen tanpa kebocoran kami berarti setiap meja yang menunjukkan rembesan dalam periode garansi akan diperbaiki atau diganti sesuai jaminan kualitas kami.
Semua meja operasi listrik dan elektro-hidrolik termasuk cadangan baterai berkapasitas tinggi bawaan yang aktif secara otomatis saat listrik padam, mendukung sekitar 50 hingga 80 siklus artikulasi penuh sehingga prosedur dapat diselesaikan dengan aman. Kontrol override manual pada kolom menyediakan lapisan redundansi kedua.
Ya. Meja dilengkapi dengan rel samping baja tahan karat standar yang kompatibel dengan berbagai aksesori modular, termasuk rangka traksi ortopedi, penyangga kaki, papan lengan, layar anestesi, dan penempat kepala. Paket khusus untuk ortopedi, ginekologi, dan urologi dapat dikonfigurasi sebelum pengiriman.
Kami mengunci sampel emas dan dokumen teknis pada saat konfirmasi pesanan. Produksi massal mengikuti bill of materials, perlengkapan pengelasan, dan protokol pengujian yang sama, dan setiap batch lulus inspeksi penerimaan, dalam proses, dan pra-pengiriman dengan uji beban dan siklus yang dicatat per unit. Inspeksi pra-pengiriman pihak ketiga dipersilakan.
MOQ standar adalah 10 unit per model dengan pengisian kontainer campuran (mixed-model) tersedia. Waktu produksi tipikal adalah 25 hingga 35 hari setelah deposit dan konfirmasi spesifikasi. Setiap meja operasi memiliki garansi setidaknya 12 bulan sejak pengiriman, didukung oleh pasokan suku cadang seumur hidup dan dukungan teknis jarak jauh.
Electric operating tables use low-voltage DC linear actuators with programmable memory positions and oil-free maintenance, rated to 250 kg. Hydraulic (electro-hydraulic) tables drive sealed cylinders for smoother, quieter articulation under loads up to 300 kg, making them the standard for orthopedic, bariatric, and C-arm imaging cases. Our electric vs. hydraulic comparison guide covers selection in detail.
Surgical table (OT table) pricing is driven by drive system, safe working load, C-arm radiolucency, and specialty accessories. Mechanical foot-pump tables are the lowest-cost entry point, electric models sit mid-range, and electro-hydraulic C-arm compatible configurations with orthopedic traction frames carry the highest price. As a factory-direct operating table manufacturer, we quote per configuration: send your tender BOQ for pricing.
A C-arm compatible operating table lets a mobile C-arm X-ray unit image the patient without obstruction. It combines radiolucent (X-ray transparent) tabletop panels, a longitudinal sliding top (up to 300 mm on our models) and an open C-shaped base so the gantry can orbit from head to pelvis. This is essential for orthopedic trauma, urology, and cardiovascular fluoroscopy.
Safe working load (SWL) is the maximum patient-plus-accessory weight an operating table can hold through full articulation, including Trendelenburg tilt. Standard electric tables are rated around 200–250 kg, while heavy-duty electro-hydraulic models reach 300 kg (660 lbs) for bariatric surgery. Every Sanyang table is load-tested at rated capacity before shipment, with the test record included in the export documentation.
Yes. As an orthopedic operating table manufacturer, we configure electric and electro-hydraulic tables with traction frames, boot stirrups, sacral supports, and counter-traction posts for hip, femoral, and tibial nailing. Radiolucent tabletops support continuous C-arm fluoroscopy, and each orthopedic package ships pre-assembled with the table, backed by long-term spare-parts supply.
Operating tables are usually procured as part of a wider theater package. These categories ship from the same factory and consolidate into one container and one document set.
Send your tender schedule, target configuration, or a photo of your current room. Our export engineers will reply with a matched model proposal, C-arm compatibility confirmation, accessory list, and container-loading plan.