{"id":3653,"date":"2026-08-06T22:20:38","date_gmt":"2026-08-06T22:20:38","guid":{"rendered":"https:\/\/sanyangmedical.com\/mobile-surgical-light-setup\/"},"modified":"2026-09-05T19:43:55","modified_gmt":"2026-09-05T19:43:55","slug":"mobile-surgical-light-setup","status":"publish","type":"post","link":"https:\/\/sanyangmedical.com\/id\/mobile-surgical-light-setup\/","title":{"rendered":"Pengaturan Lampu Bedah Mobile: Penempatan, Pengisian Daya, dan Pemeriksaan Keselamatan"},"content":{"rendered":"<p><!-- WP Post HTML --><br \/>\n<!-- Rank Math SEO --><br \/>\n<!-- Title: Mobile Surgical Light Setup: Placement, Charging and Safety Checks --><br \/>\n<!-- Slug: mobile-surgical-light-setup --><br \/>\n<!-- Focus Keyword: mobile surgical light setup --><br \/>\n<!-- Meta Description: Step-by-step guide to setting up a mobile surgical light: placement best practices, battery charging routines, and pre-use safety checks for operating rooms and clinics. --><br \/>\n<!-- Category: installation-maintenance --><\/p>\n<article class=\"sy-article\">\n<figure class=\"sy-article__featured\">\n    <img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-surgical-light-factory-photo-charlie-1920w.webp\" alt=\"Mobile LED 500 surgical light on floor stand base with casters in operating room\" width=\"1920\" height=\"1080\" loading=\"eager\"><figcaption>A mobile LED 500 surgical light on a floor stand base with lockable casters, ready for positioning in an operating room.<\/figcaption><\/figure>\n<div class=\"sy-article__body\">\n<p>Mobile surgical lights fill a critical gap in healthcare facilities where ceiling-mounted illumination is impractical or unavailable. Outpatient clinics, field hospitals, veterinary practices, and emergency triage areas all rely on floor-standing surgical lamps to deliver the concentrated, shadow-reduced light that procedural work demands. Unlike their ceiling-mounted counterparts, mobile lights must be positioned manually before each use, charged or plugged in, and inspected for stability on a regular basis.<\/p>\n<p>This guide provides a practical, step-by-step framework for setting up a mobile surgical light correctly. It covers placement strategy, battery and power management, and the safety checks that biomedical technicians and clinical staff should perform before every procedure. For facilities evaluating their overall equipment needs, our overview of <a href=\"https:\/\/sanyangmedical.com\/clinic-equipment-package-deals\/\">clinic equipment package deals<\/a> covers how mobile lights fit into a broader procurement plan.<\/p>\n<h2>Choosing the Right Location for a Mobile Surgical Light<\/h2>\n<p>Placement is the single most important factor in mobile surgical light performance. A light positioned even a few centimeters off-axis can introduce shadows from the surgeon&#8217;s hands or instruments, defeating the purpose of a shadow-reducing reflector design.<\/p>\n<p>The World Health Organization&#8217;s fact sheet on medical devices emphasizes that proper equipment deployment is essential for patient safety, particularly in resource-constrained settings where backup options may be limited. The <a href=\"https:\/\/www.who.int\/news-room\/fact-sheets\/detail\/medical-devices\" target=\"_blank\" rel=\"noopener\">WHO medical devices guidance<\/a> notes that even simple devices require correct setup to function as intended.<\/p>\n<p>Follow these placement principles:<\/p>\n<ul>\n<li><strong>Center the light head above the procedural site.<\/strong> The optical axis of the reflector should be perpendicular to the wound or examination area. Most mobile lights offer an articulating arm with 2 to 3 joints that allow fine adjustment of the head angle.<\/li>\n<li><strong>Maintain the recommended working distance.<\/strong> For most LED mobile surgical lights, the optimal distance between the light head and the surgical site is 600 mm to 1,200 mm. At this range, the light achieves its rated central illuminance (typically 40,000 to 100,000 lux) and the beam diameter covers the required field size.<\/li>\n<li><strong>Keep the base clear of foot traffic.<\/strong> The floor stand base is usually 550 mm to 650 mm in diameter. Position it so that circulating staff will not trip over it or accidentally bump it during the procedure. A bumped light can shift out of alignment, requiring repositioning mid-procedure.<\/li>\n<li><strong>Ensure all caster brakes are engaged.<\/strong> Mobile surgical lights are equipped with swivel casters for mobility. Before any procedure, verify that all casters (typically 4 to 5) have their brakes fully engaged. A rolling light is a patient safety hazard.<\/li>\n<\/ul>\n<h2>Understanding the Base and Caster System<\/h2>\n<figure>\n      <img decoding=\"async\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/caster-brake-closeup.png\" alt=\"Close-up of hospital trolley swivel caster with engaged total-lock brake mechanism\" width=\"1024\" height=\"768\" loading=\"lazy\"><figcaption>Close-up of a total-lock caster brake mechanism. The brake locks both wheel rotation and swivel movement simultaneously.<\/figcaption><\/figure>\n<p>The base of a mobile surgical light serves two purposes: it provides stability (preventing the light from tipping when the arm is fully extended) and it houses the casters for mobility. Most bases are made from heavy-gauge steel or cast iron, with a total weight of 25 kg to 40 kg to ensure a low center of gravity.<\/p>\n<p>The caster system typically consists of 4 to 5 swivel casters with dual-lock brakes. The dual-lock mechanism secures both the wheel rotation and the swivel pivot, preventing any movement in any direction. When inspecting casters, check for:<\/p>\n<figure>\n      <img decoding=\"async\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-surgical-light-led-500-floor-stand-product-photo-india-3-scaled-1536w.webp\" alt=\"Sanyang Medical LED 500 mobile surgical light floor stand with casters and adjustable arm\" width=\"1536\" height=\"2048\" loading=\"lazy\"><figcaption>The LED 500 floor stand combines a low center of gravity with lockable casters and a fully articulating arm for precise head positioning.<\/figcaption><\/figure>\n<ul>\n<li><strong>Wheel tread wear:<\/strong> Polyurethane or rubber treads can develop flat spots if the light has been stored in the same position for an extended period. Flat-spotted wheels cause the base to rock, compromising stability.<\/li>\n<li><strong>Brake engagement force:<\/strong> The brake pedal should engage firmly with foot pressure. A brake that requires excessive force or fails to hold indicates a worn mechanism that needs replacement.<\/li>\n<li><strong>Swivel play:<\/strong> Excessive play in the swivel bearing can cause the base to drift slightly when the arm is moved. This is a sign that the swivel bearing needs lubrication or replacement.<\/li>\n<\/ul>\n<h2>Power Management: Battery, Mains, and Hybrid Units<\/h2>\n<p>Mobile surgical lights come in three power configurations:<\/p>\n<ol>\n<li><strong>Mains-powered only:<\/strong> The light must be plugged into a standard electrical outlet (100&ndash;240 V AC, 50\/60 Hz). These units are the most common and offer unlimited runtime, but they require a nearby power outlet and create a cable management challenge.<\/li>\n<li><strong>Battery-powered:<\/strong> An integrated rechargeable battery (typically lithium-ion, 20 Ah to 50 Ah capacity) provides cordless operation for 4 to 10 hours depending on the brightness setting. Battery life decreases as the light is operated at maximum intensity.<\/li>\n<li><strong>Hybrid (mains + battery):<\/strong> The light can operate on mains power while simultaneously charging the battery. If mains power fails, the unit switches to battery automatically. This configuration offers the highest level of operational continuity.<\/li>\n<\/ol>\n<p>For battery-powered and hybrid units, follow these charging best practices:<\/p>\n<ul>\n<li><strong>Charge after every use.<\/strong> Do not wait for the battery to fully deplete before recharging. Lithium-ion batteries perform best when kept between 20% and 80% state of charge for daily use. A full charge cycle (to 100%) should be performed at least once per week to calibrate the battery gauge.<\/li>\n<li><strong>Observe the charging indicator.<\/strong> Most units have an LED indicator that shows charging status (red = charging, green = full). If the indicator does not illuminate when the charger is connected, check the power cable, the charger port, and the internal fuse before assuming the battery is faulty.<\/li>\n<li><strong>Store at partial charge.<\/strong> If the light will not be used for more than two weeks, charge the battery to approximately 50% and store the unit in a cool, dry location. Storing a lithium-ion battery at 100% or 0% for extended periods accelerates capacity loss.<\/li>\n<li><strong>Replace the battery on schedule.<\/strong> Most manufacturers recommend battery replacement every 2 to 3 years or after 500 full charge cycles, whichever comes first. A battery that no longer holds a charge for the expected duration should be replaced promptly.<\/li>\n<\/ul>\n<h2>Pre-Use Safety Checklist<\/h2>\n<p>Before every procedure, the operating nurse or biomedical technician should perform a brief safety check. This checklist takes less than two minutes and covers the items most likely to cause a problem during use:<\/p>\n<ol>\n<li><strong>Caster brakes:<\/strong> All brakes engaged, base does not roll when the arm is moved.<\/li>\n<li><strong>Arm joints:<\/strong> All articulation joints hold position when released. The arm should not drift or sag under the weight of the light head.<\/li>\n<li><strong>Light head:<\/strong> All LEDs illuminate uniformly. No flickering, no dead LEDs, no visible damage to the lens or reflector surface.<\/li>\n<li><strong>Intensity control:<\/strong> The dimmer responds smoothly from minimum to maximum. No dead zones or erratic behavior.<\/li>\n<li><strong>Color temperature:<\/strong> If the light offers adjustable color temperature (typically 3,500 K to 5,500 K), verify that the adjustment control works and the light output changes accordingly.<\/li>\n<li><strong>Power supply:<\/strong> For mains-powered units, the power cable is intact with no visible damage to the insulation or plug. For battery units, the charge level is sufficient for the expected procedure duration plus a 30-minute safety margin.<\/li>\n<li><strong>Sterile handle:<\/strong> If a sterile handle is attached, it is secure and the attachment mechanism (clamp, threaded stud, or bayonet) is fully engaged.<\/li>\n<li><strong>Cable management:<\/strong> The power cable (if present) is routed along the floor or through a cable management channel, not across a walkway.<\/li>\n<\/ol>\n<h2>Articulating Arm Adjustment and Maintenance<\/h2>\n<p>The articulating arm is the most mechanically complex component of a mobile surgical light. It must support the weight of the light head (typically 3 kg to 8 kg) while allowing smooth, precise repositioning. Over time, the friction joints can loosen, causing the arm to sag or drift.<\/p>\n<p>Most arms use a spring-balanced or friction-lock mechanism. Spring-balanced arms counterbalance the light head weight with a tension spring, requiring minimal effort to move. Friction-lock arms rely on adjustable friction at each joint to hold position. Both types require periodic adjustment. For a detailed explanation of how to rebalance an arm that has begun to sag, see our guide on <a href=\"https:\/\/sanyangmedical.com\/surgical-light-arm-rebalancing\/\">surgical light arm rebalancing<\/a>.<\/p>\n<p>When adjusting the arm, always support the light head with one hand while loosening or tightening the joint adjustment with the other. Releasing a joint without support can cause the arm to snap downward, potentially damaging the joint mechanism or injuring the technician.<\/p>\n<h2>Troubleshooting Common Setup Issues<\/h2>\n<p>Even with proper setup procedures, issues can arise. Here are the most common problems and their solutions:<\/p>\n<ul>\n<li><strong>Light flickers at high intensity:<\/strong> This usually indicates a failing power supply or a loose connection at the battery terminal. For mains-powered units, check the power cable and outlet. For battery units, inspect the battery connector for corrosion or looseness.<\/li>\n<li><strong>Uneven beam pattern:<\/strong> A reflector or lens that has shifted out of alignment can cause hot spots or dark areas in the beam. This requires professional realignment by a qualified technician.<\/li>\n<li><strong>Arm will not hold position:<\/strong> The friction joints need tightening. Refer to the arm adjustment procedure in the user manual, or consult the manufacturer&#8217;s service department.<\/li>\n<li><strong>Battery drains faster than expected:<\/strong> The battery may have reached the end of its useful life. Check the charge cycle count (if the unit displays it) and compare with the manufacturer&#8217;s rated lifespan.<\/li>\n<\/ul>\n<p>For a broader look at installation and setup errors that can affect all types of operating room equipment, our article on <a href=\"https:\/\/sanyangmedical.com\/or-equipment-installation-commissioning\/\">OR equipment installation and commissioning<\/a> provides additional context and prevention strategies.<\/p>\n<div class=\"yt-facade\" data-yt-id=\"40EFUho0xP0\" role=\"button\" aria-label=\"Play video: Operating Room Introduction | Incision\" style=\"position:relative;width:100%;padding-bottom:56.25%;background:#000;border-radius:8px;margin:24px 0;cursor:pointer;overflow:hidden\">\n<div style=\"position:absolute;top:0;left:0;width:100%;height:100%;display:flex;align-items:center;justify-content:center\"><\/div>\n<\/p><\/div>\n<p>For the complete range of options and a specification sheet on Surgical Lights, see our <a href=\"\/products\/surgical-lights\/\" data-pillar=\"1\">Surgical Lights<\/a> product guide.<\/p>\n<p>    (function(){var f=document.querySelectorAll(&#8216;.yt-facade&#8217;);for(var i=0;i&lt;f.length;i++){(function(el){el.addEventListener(&#039;click&#039;,function(){var id=el.getAttribute(&#039;data-yt-id&#039;);el.innerHTML=&#039;&#8217;;});})(f[i]);}})();<\/p>\n<h2>Summary<\/h2>\n<p>Setting up a mobile surgical light correctly is a straightforward process when the key factors &mdash; placement, power management, and safety checks &mdash; are addressed systematically. The investment in a two-minute pre-use checklist pays dividends in procedural efficiency and patient safety. For facilities that are outfitting a new clinic or expanding an existing one, mobile surgical lights offer a flexible, cost-effective alternative to ceiling-mounted systems, particularly in spaces where structural modifications are impractical.<\/p>\n<\/p><\/div>\n<section class=\"sy-article__faq\" id=\"faq\">\n<h2>Frequently Asked Questions<\/h2>\n<h3>How far should a mobile surgical light be from the surgical site?<\/h3>\n<p>The optimal working distance for most mobile LED surgical lights is 600 mm to 1,200 mm from the light head to the surgical site. At this range, the light achieves its rated central illuminance and beam coverage.<\/p>\n<h3>How long does a mobile surgical light battery last?<\/h3>\n<p>Battery runtime depends on the model and brightness setting. Typical lithium-ion batteries in mobile surgical lights provide 4 to 10 hours of continuous use. Runtime decreases at maximum brightness settings.<\/p>\n<h3>Can a mobile surgical light be used while charging?<\/h3>\n<p>Hybrid units (mains + battery) can operate while charging. Pure battery units may or may not support pass-through charging; check the manufacturer&#8217;s specifications.<\/p>\n<h3>How often should the caster brakes be inspected?<\/h3>\n<p>Caster brakes should be checked before every use as part of the pre-procedure safety checklist. A full mechanical inspection of the caster wheels and brake mechanisms should be performed during scheduled preventive maintenance, typically every 6 months.<\/p>\n<h3>What is the typical weight of a mobile surgical light?<\/h3>\n<p>The total unit weight (including base, stand, arm, and light head) typically ranges from 35 kg to 65 kg. The base alone weighs 25 kg to 40 kg to provide stability.<\/p>\n<\/section>\n<\/article>\n<p><!-- FAQPage Schema --><\/p>\n<p>{<br \/>\n  &#8220;@context&#8221;: &#8220;https:\/\/schema.org&#8221;,<br \/>\n  &#8220;@type&#8221;: &#8220;FAQPage&#8221;,<br \/>\n  &#8220;mainEntity&#8221;: [<br \/>\n    {<br \/>\n      &#8220;@type&#8221;: &#8220;Question&#8221;,<br \/>\n      &#8220;name&#8221;: &#8220;How far should a mobile surgical light be from the surgical site?&#8221;,<br \/>\n      &#8220;acceptedAnswer&#8221;: {<br \/>\n        &#8220;@type&#8221;: &#8220;Answer&#8221;,<br \/>\n        &#8220;text&#8221;: &#8220;The optimal working distance for most mobile LED surgical lights is 600 mm to 1,200 mm from the light head to the surgical site. At this range, the light achieves its rated central illuminance and beam coverage.&#8221;<br \/>\n      }<br \/>\n    },<br \/>\n    {<br \/>\n      &#8220;@type&#8221;: &#8220;Question&#8221;,<br \/>\n      &#8220;name&#8221;: &#8220;How long does a mobile surgical light battery last?&#8221;,<br \/>\n      &#8220;acceptedAnswer&#8221;: {<br \/>\n        &#8220;@type&#8221;: &#8220;Answer&#8221;,<br \/>\n        &#8220;text&#8221;: &#8220;Battery runtime depends on the model and brightness setting. Typical lithium-ion batteries in mobile surgical lights provide 4 to 10 hours of continuous use. Runtime decreases at maximum brightness settings.&#8221;<br \/>\n      }<br \/>\n    },<br \/>\n    {<br \/>\n      &#8220;@type&#8221;: &#8220;Question&#8221;,<br \/>\n      &#8220;name&#8221;: &#8220;Can a mobile surgical light be used while charging?&#8221;,<br \/>\n      &#8220;acceptedAnswer&#8221;: {<br \/>\n        &#8220;@type&#8221;: &#8220;Answer&#8221;,<br \/>\n        &#8220;text&#8221;: &#8220;Hybrid units (mains + battery) can operate while charging. Pure battery units may or may not support pass-through charging; check the manufacturer&#8217;s specifications.&#8221;<br \/>\n      }<br \/>\n    },<br \/>\n    {<br \/>\n      &#8220;@type&#8221;: &#8220;Question&#8221;,<br \/>\n      &#8220;name&#8221;: &#8220;How often should the caster brakes be inspected?&#8221;,<br \/>\n      &#8220;acceptedAnswer&#8221;: {<br \/>\n        &#8220;@type&#8221;: &#8220;Answer&#8221;,<br \/>\n        &#8220;text&#8221;: &#8220;Caster brakes should be checked before every use as part of the pre-procedure safety checklist. A full mechanical inspection of the caster wheels and brake mechanisms should be performed during scheduled preventive maintenance, typically every 6 months.&#8221;<br \/>\n      }<br \/>\n    },<br \/>\n    {<br \/>\n      &#8220;@type&#8221;: &#8220;Question&#8221;,<br \/>\n      &#8220;name&#8221;: &#8220;What is the typical weight of a mobile surgical light?&#8221;,<br \/>\n      &#8220;acceptedAnswer&#8221;: {<br \/>\n        &#8220;@type&#8221;: &#8220;Answer&#8221;,<br \/>\n        &#8220;text&#8221;: &#8220;The total unit weight (including base, stand, arm, and light head) typically ranges from 35 kg to 65 kg. The base alone weighs 25 kg to 40 kg to provide stability.&#8221;<br \/>\n      }<br \/>\n    }<br \/>\n  ]<br \/>\n}<\/p>\n<p><!-- GEO AI Block --><\/p>\n<p>{<br \/>\n  &#8220;@context&#8221;: &#8220;https:\/\/schema.org&#8221;,<br \/>\n  &#8220;@type&#8221;: &#8220;Article&#8221;,<br \/>\n  &#8220;headline&#8221;: &#8220;Mobile Surgical Light Setup: Placement, Charging and Safety Checks&#8221;,<br \/>\n  &#8220;description&#8221;: &#8220;Step-by-step guide to setting up a mobile surgical light: placement best practices, battery charging routines, caster inspection, and pre-use safety checks for operating rooms and clinics.&#8221;,<br \/>\n  &#8220;author&#8221;: {<br \/>\n    &#8220;@type&#8221;: &#8220;Organization&#8221;,<br \/>\n    &#8220;name&#8221;: &#8220;Sanyang Medical&#8221;,<br \/>\n    &#8220;url&#8221;: &#8220;https:\/\/sanyangmedical.com&#8221;<br \/>\n  },<br \/>\n  &#8220;publisher&#8221;: {<br \/>\n    &#8220;@type&#8221;: &#8220;Organization&#8221;,<br \/>\n    &#8220;name&#8221;: &#8220;Sanyang Medical&#8221;,<br \/>\n    &#8220;url&#8221;: &#8220;https:\/\/sanyangmedical.com&#8221;<br \/>\n  },<br \/>\n  &#8220;datePublished&#8221;: &#8220;2026-08-06&#8221;,<br \/>\n  &#8220;dateModified&#8221;: &#8220;2026-08-06&#8221;,<br \/>\n  &#8220;mainEntityOfPage&#8221;: {<br \/>\n    &#8220;@type&#8221;: &#8220;WebPage&#8221;,<br \/>\n    &#8220;@id&#8221;: &#8220;https:\/\/sanyangmedical.com\/mobile-surgical-light-setup\/&#8221;<br \/>\n  },<br \/>\n  &#8220;keywords&#8221;: &#8220;mobile surgical light, surgical light setup, mobile operating light, surgical light battery, surgical light safety check, floor stand surgical light&#8221;,<br \/>\n  &#8220;articleSection&#8221;: &#8220;Installation &amp; Maintenance&#8221;,<br \/>\n  &#8220;geo&#8221;: {<br \/>\n    &#8220;@type&#8221;: &#8220;GeoCoordinates&#8221;,<br \/>\n    &#8220;latitude&#8221;: &#8220;35.5&#8221;,<br \/>\n    &#8220;longitude&#8221;: &#8220;117.39&#8221;<br \/>\n  }<br \/>\n}<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A mobile LED 500 surgical light on a floor stand base with lockable casters, ready for positioning in an operating room. Mobile surgical lights fill a critical gap in healthcare facilities where ceiling-mounted illumination is impractical or unavailable. Outpatient clinics, field hospitals, veterinary practices, and emergency triage areas all rely on floor-standing surgical lamps to &#8230; <a title=\"Pengaturan Lampu Bedah Mobile: Penempatan, Pengisian Daya, dan Pemeriksaan Keselamatan\" class=\"read-more\" href=\"https:\/\/sanyangmedical.com\/id\/mobile-surgical-light-setup\/\" aria-label=\"Baca selengkapnya tentang Mobile Surgical Light Setup: Placement, Charging and Safety Checks\">Baca Selengkapnya<\/a><\/p>","protected":false},"author":1,"featured_media":2713,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_title":"Mobile Surgical Light Setup: Placement, Charging and Safety Checks | Sanyang","rank_math_description":"Step-by-step mobile surgical light setup: placement best practices, battery charging routines, caster inspection and pre-use safety checks for ORs and clinics.","rank_math_focus_keyword":"mobile surgical light setup","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_yoast_wpseo_focuskw":"","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":"","footnotes":""},"categories":[112],"tags":[],"class_list":["post-3653","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-installation-maintenance"],"_links":{"self":[{"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/posts\/3653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/comments?post=3653"}],"version-history":[{"count":1,"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/posts\/3653\/revisions"}],"predecessor-version":[{"id":4023,"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/posts\/3653\/revisions\/4023"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/media\/2713"}],"wp:attachment":[{"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/media?parent=3653"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/categories?post=3653"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sanyangmedical.com\/id\/wp-json\/wp\/v2\/tags?post=3653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}