{"id":3739,"date":"2026-08-12T12:13:30","date_gmt":"2026-08-12T12:13:30","guid":{"rendered":"https:\/\/sanyangmedical.com\/operating-table-top-sections-five-section-design\/"},"modified":"2026-09-25T19:40:28","modified_gmt":"2026-09-25T19:40:28","slug":"operating-table-top-sections-five-section-design","status":"publish","type":"post","link":"https:\/\/sanyangmedical.com\/fr\/operating-table-top-sections-five-section-design\/","title":{"rendered":"Operating Table Top Sections: Five-Section Design Explained"},"content":{"rendered":"<p><!-- Rank Math SEO --><br \/>\n<!-- Title: Operating Table Top Sections: Five-Section Design Explained | Sanyang --><br \/>\n<!-- Slug: operating-table-top-sections-five-section-design --><br \/>\n<!-- Focus Keyword: operating table top sections --><br \/>\n<!-- Meta Description: Five-section operating table tops explained: what each section does, how articulation and locking work, radiolucent materials, and the datasheet checks buyers should run. --><br \/>\n<!-- Category: surgical-equipment-guides --><\/p>\n<p>The operating table top sections decide what a surgical team can and cannot do with a patient. A five-section top splits the support surface into head, back, seat, and two leg sections, each moving on its own axis, and that split is why one table can handle neurosurgery in the morning and lithotomy in the afternoon. Buyers who understand the section layout before purchase avoid the two classic failures: a table that cannot reach the position the procedure demands, and a top whose joints block the imaging beam.<\/p>\n<p>Most procurement documents describe the top as a single line item, yet the section design carries the load ratings, the articulation angles, and the radiolucent window. This guide walks through each section, what moves it, what locks it, and what to verify on the datasheet before the table enters your operating room.<\/p>\n<div class=\"yt-facade\" data-yt-id=\"SQRpKAB2fGA\" role=\"button\" tabindex=\"0\" aria-label=\"Play video: Patient Positioning on the Surgical Table - Incision\" style=\"position:relative;width:100%;padding-bottom:56.25%;background:#000;border-radius:8px;margin:24px 0;cursor:pointer;overflow:hidden;\">\n<div style=\"position:absolute;top:0;left:0;width:100%;height:100%;display:flex;align-items:center;justify-content:center;\">\n<svg width=\"68\" height=\"48\" viewBox=\"0 0 68 48\"><path d=\"M66.52 7.5c.78 2.94.78 15 0 17.94a8.5 8.5 0 01-6 6C57.58 32.22 34 32.22 34 32.22s-23.58 0-26.52-.78a8.5 8.5 0 01-6-6C.7 22.5.7 10.44 1.48 7.5a8.5 8.5 0 016-6C10.42.72 34 .72 34 .72s23.58 0 26.52.78a8.5 8.5 0 016 6z\" fill=\"red\"\/><path d=\"M45 24L27 14v20\" fill=\"white\"\/><\/svg>\n<\/div>\n<\/div>\n<h2>What a Five-Section Top Actually Does<\/h2>\n<p>A five-section top is a patient support surface with five independently articulated segments. The head section supports the skull and cervical spine, the back section carries the torso and can be raised for sitting positions, the seat section sits fixed over the table column, and the two leg sections support the lower limbs. On tables with split legs, the two leg plates adjust independently, which is what makes lithotomy, urology, and gynecology procedures practical on the same table as general surgery.<\/p>\n<p>The number of sections is a design decision, not a marketing feature. Fewer sections means fewer joints, cheaper construction, and simpler maintenance. More sections means finer positioning, wider procedure coverage, and more hinge and lock hardware to inspect. The five-section layout is the industry standard because it covers the largest share of surgical positions without adding the complexity of a sixth or seventh segment. Mechanical tables achieve the same geometry with gear-driven sections and manual cranks, while electric and electro-hydraulic models move each section with actuators or sealed hydraulic cylinders.<\/p>\n<h2>The Five Sections and Their Jobs<\/h2>\n<table>\n<thead>\n<tr>\n<th>Section<\/th>\n<th>What it supports<\/th>\n<th>Typical movement<\/th>\n<th>Procedures it enables<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Head section<\/td>\n<td>Skull, cervical spine<\/td>\n<td>Raise and lower, removable on many models<\/td>\n<td>ENT, ophthalmic, neurosurgical access<\/td>\n<\/tr>\n<tr>\n<td>Back section<\/td>\n<td>Torso, upper body<\/td>\n<td>Up to 70 degrees up, 15 degrees down<\/td>\n<td>Beach chair, sitting, thoracic positions<\/td>\n<\/tr>\n<tr>\n<td>Seat section<\/td>\n<td>Pelvis, lower torso<\/td>\n<td>Fixed to the column; tilts with the table<\/td>\n<td>Trendelenburg and lateral tilt anchor point<\/td>\n<\/tr>\n<tr>\n<td>Leg section (left)<\/td>\n<td>Left lower limb<\/td>\n<td>Lower, raise, flex, abduct<\/td>\n<td>Orthopedic and trauma access<\/td>\n<\/tr>\n<tr>\n<td>Leg section (right)<\/td>\n<td>Right lower limb<\/td>\n<td>Independent of the left plate<\/td>\n<td>Lithotomy, urology, gynecology<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The back and leg sections carry the most demanding load cases because they cantilever away from the column. On Sanyang tables the back section rises to 70 degrees and lowers to 15 degrees, and the split leg plates adjust independently, so one leg can stay flat while the other is positioned for a fracture case. Trendelenburg and reverse Trendelenburg reach 25 degrees under rated load, and lateral tilt reaches 15 degrees. Those angles matter only when the table is loaded, which is why the test report should state them under load, not on an empty tabletop.<\/p>\n<h2>Removable Sections and Interchangeable Tops<\/h2>\n<p><img decoding=\"async\" class=\"wp-image-2757\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-romeo-scaled-1024w.webp\" alt=\"Radiolucent carbon-style operating tabletop section prepared for C-arm fluoroscopy\" width=\"1024\" height=\"1820\" loading=\"lazy\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-romeo-scaled-1024w.webp 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-romeo-scaled-1024w-169x300.webp 169w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-romeo-scaled-1024w-576x1024.webp 576w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-romeo-scaled-1024w-768x1365.webp 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-romeo-scaled-1024w-864x1536.webp 864w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-romeo-scaled-1024w-7x12.webp 7w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>The head section unclips on most five-section designs so the anesthesiologist can stand at the head end or so an occipital ring can be fitted for pediatric cases. The leg sections detach as a pair on some models, converting the table to a shorter platform for ENT or ophthalmic work where lower-limb support is not needed. Interchangeable tops go one step further: the whole five-section surface lifts off and a pediatric top or a bariatric top clips into the same column, letting one base serve two patient populations.<\/p>\n<p>Removability has a maintenance cost. Every detachable section adds a locking mechanism, and every locking mechanism is a wear point and a potential radiopaque intrusion into the imaging window. When a supplier offers interchangeable tops, ask how the alignment between top and column is guaranteed after repeated swaps, and what the inspection interval is for the locking pins. The <a href=\"https:\/\/sanyangmedical.com\/products\/operating-tables\/\">Sanyang Medical operating table range<\/a> configures section sets per application, with the same column accepting standard, pediatric, and bariatric top layouts for hospital groups that standardize on one base model.<\/p>\n<h2>Section Articulation, Actuators, and Locks<\/h2>\n<p><img decoding=\"async\" class=\"wp-image-2867\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-juliet-scaled-1920w.webp\" alt=\"Operating table with articulated leg section, side rails and full-length accessory rails\" width=\"1920\" height=\"1440\" loading=\"lazy\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-juliet-scaled-1920w.webp 1920w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-juliet-scaled-1920w-300x225.webp 300w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-juliet-scaled-1920w-1024x768.webp 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-juliet-scaled-1920w-768x576.webp 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-juliet-scaled-1920w-1536x1152.webp 1536w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-juliet-scaled-1920w-16x12.webp 16w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<p>Each of the operating table top sections hinges at a joint whose design determines smoothness and long-term wear. Electric tables use linear actuators with mechanical screws, electro-hydraulic tables use sealed cylinders driven by a motorized pump, and mechanical tables use gear-driven sections operated by foot pump or crank. Whatever the drive, the section locks are the safety-critical part: mechanical and electronic interlocks hold every section under rated load, so a table set for a long case does not drift during the procedure.<\/p>\n<p>The international benchmark for these behaviors is <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/68385\" target=\"_blank\" rel=\"noopener\">IEC 60601-2-46:2023<\/a>, the particular standard for basic safety and essential performance of operating tables. It defines the mechanical test framework behind load ratings, the stability requirements at maximum tilt, and the essential performance criteria for position holding. A test report that names IEC 60601-2-46 documents that the section locks, hinges, and actuators were tested as a system, not as individual components.<\/p>\n<h2>Materials and the Imaging Window<\/h2>\n<p><img decoding=\"async\" class=\"wp-image-2767\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-tango-scaled-1024w.webp\" alt=\"Radiolucent operating tabletop section designed for C-arm X-ray transmission\" width=\"1024\" height=\"1820\" loading=\"lazy\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-tango-scaled-1024w.webp 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-tango-scaled-1024w-169x300.webp 169w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-tango-scaled-1024w-576x1024.webp 576w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-tango-scaled-1024w-768x1365.webp 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-tango-scaled-1024w-864x1536.webp 864w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-tango-scaled-1024w-7x12.webp 7w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>Section material determines whether the top can carry imaging procedures. Stainless steel is strong and cheap but blocks X-rays, which is why steel tops serve general surgery rooms without fluoroscopy. Carbon fiber panels pass the beam with low attenuation and extend the radiolucent zone up to 1400 mm on full-length designs, while budget tables combine a steel main section with a short radiolucent extension that forces the team to align the anatomy over one window. The section joints matter as much as the panels: every hinge and lock is a potential radiopaque intrusion, so the declared imaging window must sit clear of all hardware.<\/p>\n<p>Sanyang electric and electro-hydraulic tables use radiolucent tabletop panels with a longitudinal slide of up to 300 mm, so the C-arm gantry reaches head-to-pelvis imaging zones without repositioning the patient. For imaging-heavy departments, the <a href=\"https:\/\/sanyangmedical.com\/radiolucent-carbon-fiber-operating-table-tops\/\">carbon fiber operating table top guide<\/a> compares materials, attenuation values, and radiolucent zone lengths, and the <a href=\"https:\/\/sanyangmedical.com\/c-arm-compatible-operating-table-guide\/\">C-arm compatible operating table guide<\/a> covers base geometry and slide travel in detail.<\/p>\n<h2>Datasheet Checks Before You Buy<\/h2>\n<p>Five numbers on the datasheet separate a table that positions well from a table that looks good in a brochure:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Section angles under load<\/strong> \u2014 back up\/down, Trendelenburg, reverse, and lateral tilt stated at rated load, not empty.<\/li>\n<li><strong>Point-load rating<\/strong> \u2014 the maximum load concentrated at the center of the torso section, not just the table-level safe working load.<\/li>\n<li><strong>Radiolucent zone length<\/strong> \u2014 where the declared imaging window starts and ends, and which hinges fall inside it.<\/li>\n<li><strong>Accessory weight allowance<\/strong> \u2014 stirrups, traction frames, and arm boards add 15-40 kg at the worst lever arm and must count toward the load.<\/li>\n<li><strong>Lock hold test<\/strong> \u2014 the report should state how long every section holds position under load, per the IEC 60601-2-46 mechanical test framework.<\/li>\n<\/ul>\n<p>Load ratings assume a uniformly distributed patient, and a 250 kg patient whose mass concentrates in the torso creates a different stress profile than 250 kg spread evenly. The <a href=\"https:\/\/sanyangmedical.com\/operating-table-safe-working-load-guide\/\">operating table safe working load guide<\/a> explains how to read these figures across vendors and what to ask when the rating changes between positions. Verify the section angles by operating the table during the factory visit or sample test, and confirm the lock holds with the tabletop at full Trendelenburg.<\/p>\n<p>Five-section tops are the workhorse of modern operating rooms for a reason: they cover the widest procedure list with the least hardware. The design pays off when the sections, locks, and materials are specified correctly at purchase, tested during commissioning, and exercised during preventive maintenance.<\/p>\n<section class=\"sy-faq\">\n<h2>Operating Table Top Sections FAQ<\/h2>\n<div class=\"faq-card\">\n<h3>What are the five sections of an operating table top?<\/h3>\n<p>The five sections are the head section, the back section, the seat section, and two leg sections. On tables with split legs, the two leg plates adjust independently to support lithotomy and orthopedic positioning.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>Which operating table top sections are removable?<\/h3>\n<p>The head section unclips on most five-section designs, and the leg sections detach on some models. Interchangeable tops take this further, letting one column accept standard, pediatric, or bariatric top layouts.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>Why are leg sections split on a five-section table?<\/h3>\n<p>Split leg sections let each plate move independently, which allows one leg to stay flat while the other is positioned. That independent movement is required for lithotomy, urology, gynecology, and many orthopedic cases.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>Is a five-section operating table top radiolucent?<\/h3>\n<p>It depends on the panel material and joint placement. Carbon fiber sections extend the radiolucent zone up to 1400 mm, while steel sections block the beam, and every hinge inside the imaging window reduces usable radiolucency.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>How much weight can operating table top sections carry?<\/h3>\n<p>Table-level safe working loads reach 300 kg on heavy-duty electro-hydraulic models, 250 kg on electric models, and 200 kg on mechanical models. Section-level point loads, especially at the torso section center, should be confirmed separately.<\/p>\n<\/div>\n<\/section>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What are the five sections of an operating table top?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The five sections are the head section, the back section, the seat section, and two leg sections. On tables with split legs, the two leg plates adjust independently to support lithotomy and orthopedic positioning.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which operating table top sections are removable?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The head section unclips on most five-section designs, and the leg sections detach on some models. Interchangeable tops take this further, letting one column accept standard, pediatric, or bariatric top layouts.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why are leg sections split on a five-section table?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Split leg sections let each plate move independently, which allows one leg to stay flat while the other is positioned. That independent movement is required for lithotomy, urology, gynecology, and many orthopedic cases.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is a five-section operating table top radiolucent?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It depends on the panel material and joint placement. Carbon fiber sections extend the radiolucent zone up to 1400 mm, while steel sections block the beam, and every hinge inside the imaging window reduces usable radiolucency.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How much weight can operating table top sections carry?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Table-level safe working loads reach 300 kg on heavy-duty electro-hydraulic models, 250 kg on electric models, and 200 kg on mechanical models. Section-level point loads, especially at the torso section center, should be confirmed separately.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"name\": \"Operating Table Top Sections: Five-Section Design Explained\",\n  \"description\": \"What each of the five operating table top sections does, how articulation and locking work, radiolucent materials, and the datasheet checks buyers should run before purchase.\",\n  \"author\": {\"@type\": \"Organization\", \"name\": \"Sanyang Medical\"},\n  \"publisher\": {\"@type\": \"Organization\", \"name\": \"Sanyang Medical\"},\n  \"datePublished\": \"2026-08-11\",\n  \"dateModified\": \"2026-08-11\",\n  \"mainEntityOfPage\": {\"@type\": \"WebPage\", \"@id\": \"https:\/\/sanyangmedical.com\/operating-table-top-sections-five-section-design\/\"}\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\" id=\"evo301-geo-ai-block\">\n{\n  \"definition\": \"A five-section operating table top splits the patient support surface into head, back, seat, and two independently adjustable leg sections. The arrangement lets staff position patients for procedures from neurosurgery to lithotomy, with section locks holding every segment under rated load and radiolucent panels preserving the C-arm imaging window.\",\n  \"data_statements\": [\n    \"The back section of a five-section top rises to 70 degrees and lowers to 15 degrees, with split leg plates adjustable independently.\",\n    \"Trendelenburg and reverse Trendelenburg reach 25 degrees under rated load and lateral tilt reaches 15 degrees on Sanyang tables.\",\n    \"Sanyang table dimensions are approximately 2000 mm by 500 mm with accessory rails along the full tabletop length.\",\n    \"Safe working loads reach 300 kg on heavy-duty electro-hydraulic models, 250 kg on electric models, and 200 kg on mechanical models.\",\n    \"Radiolucent tabletop panels provide up to 300 mm of longitudinal slide, and full-length carbon fiber tops extend the imaging zone to 1400 mm.\"\n  ],\n  \"qa_concise\": [\n    {\"q\": \"What is a five-section operating table top?\", \"a\": \"A patient support surface split into head, back, seat, and two independently adjustable leg sections.\"},\n    {\"q\": \"Which sections move on a five-section table?\", \"a\": \"Head, back, and both leg sections articulate; the seat section stays fixed over the column.\"},\n    {\"q\": \"Why split the leg sections?\", \"a\": \"Independent leg plates enable lithotomy, urology, gynecology, and orthopedic positioning.\"},\n    {\"q\": \"What standard governs tabletop sections?\", \"a\": \"IEC 60601-2-46, the particular standard for operating table safety and essential performance.\"}\n  ]\n}\n<\/script><\/p>\n<p><script>\n(function(){var f=document.querySelectorAll('.yt-facade');for(var i=0;i<f.length;i++){(function(el){el.addEventListener('click',function(){var id=el.getAttribute('data-yt-id');el.innerHTML='<iframe style=\"position:absolute;top:0;left:0;width:100%;height:100%\" src=\"https:\/\/www.youtube.com\/embed\/'+id+'?autoplay=1\" frameborder=\"0\" allow=\"autoplay;encrypted-media\" allowfullscreen><\/iframe>';});})(f[i]);}})();\n<\/script><\/p>\n<p>Related reading: <a href=\"https:\/\/sanyangmedical.com\/operating-table-sizing-tabletop-patient-population\/\">Operating Table Sizing: Tabletop Length vs Patient Population<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The operating table top sections decide what a surgical team can and cannot do with a patient. A five-section top splits the support surface into head, back, seat, and two leg sections, each moving on its own axis, and that split is why one table can handle neurosurgery in the morning and lithotomy in the &#8230; <a title=\"Operating Table Top Sections: Five-Section Design Explained\" class=\"read-more\" href=\"https:\/\/sanyangmedical.com\/fr\/operating-table-top-sections-five-section-design\/\" aria-label=\"En savoir plus sur Operating Table Top Sections: Five-Section Design Explained\">Lire la suite<\/a><\/p>","protected":false},"author":1,"featured_media":2778,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_title":"Operating Table Top Sections: Five-Section Design Explained | Sanyang","rank_math_description":"Five-section operating table tops explained: what each section does, how articulation and locking work, radiolucent materials, and the datasheet checks buyers should run.","rank_math_focus_keyword":"operating table top sections","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_yoast_wpseo_focuskw":"","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":"","footnotes":""},"categories":[108],"tags":[],"class_list":["post-3739","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-surgical-equipment-guides"],"_links":{"self":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/3739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/comments?post=3739"}],"version-history":[{"count":1,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/3739\/revisions"}],"predecessor-version":[{"id":3801,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/3739\/revisions\/3801"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/media\/2778"}],"wp:attachment":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/media?parent=3739"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/categories?post=3739"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/tags?post=3739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}