{"id":3705,"date":"2026-08-11T14:40:13","date_gmt":"2026-08-11T14:40:13","guid":{"rendered":"https:\/\/sanyangmedical.com\/obstetric-table-buying-guide\/"},"modified":"2026-08-12T03:06:06","modified_gmt":"2026-08-12T03:06:06","slug":"obstetric-table-buying-guide","status":"publish","type":"post","link":"https:\/\/sanyangmedical.com\/fr\/obstetric-table-buying-guide\/","title":{"rendered":"Obstetric Table Buying Guide: Delivery Beds for Maternity Suites"},"content":{"rendered":"<p>Maternity wards need a table that transitions between examination, delivery, and post-partum recovery \u2014 often within the same patient encounter. The obstetric table is the centerpiece of any delivery suite, and choosing the wrong model creates workflow bottlenecks, compromises patient positioning, and increases the risk of perineal injury during assisted delivery.<\/p>\n<p>This guide covers the specifications that matter when procuring obstetric tables: load capacity, section articulation, Trendelenburg range, mattress compatibility, and the clinical features that separate a basic gynecology exam table from a full-featured labor and delivery bed.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-1221\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-obstetric-delivery-bed-product-photo-fable-1.jpg\" alt=\"Obstetric delivery bed configured for labor and delivery room with lithotomy positioning\" width=\"1620\" height=\"1080\" loading=\"lazy\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-obstetric-delivery-bed-product-photo-fable-1.jpg 1620w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-obstetric-delivery-bed-product-photo-fable-1-300x200.jpg 300w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-obstetric-delivery-bed-product-photo-fable-1-1024x683.jpg 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-obstetric-delivery-bed-product-photo-fable-1-768x512.jpg 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-obstetric-delivery-bed-product-photo-fable-1-1536x1024.jpg 1536w\" sizes=\"auto, (max-width: 1620px) 100vw, 1620px\" \/><\/p>\n<div class=\"yt-facade\" data-yt-id=\"EcrEMhWcNGQ\" role=\"button\" tabindex=\"0\" aria-label=\"Play video: LDR Suite (Obstetrics - Labor and Delivery)\"><\/div>\n<p><script>(function(){var f=document.querySelector('.yt-facade');if(!f)return;f.innerHTML='<iframe style=\"width:100%;aspect-ratio:16\/9;border:none\" src=\"https:\/\/www.youtube.com\/embed\/'+f.dataset.ytId+'?autoplay=1\" title=\"YouTube video\" allow=\"accelerometer;autoplay;clipboard-write;encrypted-media;gyroscope;picture-in-picture\" allowfullscreen><\/iframe>';})();<\/script><\/p>\n<h2>Obstetric Table vs. Gynecology Exam Table: What Is the Difference?<\/h2>\n<p>The terms are often used interchangeably, but the two serve distinct clinical roles:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Gynecology exam table<\/strong> \u2014 designed for outpatient examinations, Pap smears, and minor procedures. Typically manual or semi-electric with limited articulation. Height range optimized for seated examination.<\/li>\n<li><strong>Obstetric delivery table<\/strong> \u2014 designed for active labor management, vaginal delivery, and instrumental delivery (forceps\/vacuum). Full electric or electro-hydraulic with multiple section articulation, deeper Trendelenburg, and higher load capacity to accommodate the patient plus attending staff.<\/li>\n<\/ul>\n<p>Some facilities use a combined obstetric-gynecology table to serve both the outpatient clinic and the delivery suite. This works for low-volume facilities, but high-throughput maternity units benefit from dedicated tables optimized for each workflow.<\/p>\n<h2>Key Specifications for Obstetric Table Procurement<\/h2>\n<p>When evaluating obstetric tables, these are the parameters that directly affect clinical performance:<\/p>\n<h3>Section Articulation<\/h3>\n<p>A quality obstetric table features at minimum three articulated sections: backrest, seat, and leg sections. Premium models add a fourth section (split leg or perineal section) that allows independent positioning for lithotomy, dorsal, or lateral delivery positions.<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Backrest:<\/strong> 0\u00b0 to 75\u00b0 for semi-recumbent delivery positioning<\/li>\n<li><strong>Seat tilt:<\/strong> -5\u00b0 to +15\u00b0 for pelvic tilt adjustment during labor<\/li>\n<li><strong>Leg sections:<\/strong> 0\u00b0 to 90\u00b0 abduction with 0\u00b0 to 45\u00b0 external rotation<\/li>\n<li><strong>Trendelenburg:<\/strong> -25\u00b0 to +25\u00b0 for fetal descent management<\/li>\n<\/ul>\n<h3>Load Capacity<\/h3>\n<p>Obstetric tables must support the patient&#8217;s weight during active pushing, which can generate dynamic loads significantly higher than static body weight. A minimum rated capacity of 180 kg is recommended. For facilities serving populations with higher BMI, bariatric-rated obstetric tables (250 kg+) are available.<\/p>\n<h3>Height Range<\/h3>\n<p>The table should adjust from approximately 650 mm (for patient transfer from wheelchair) to 900 mm (for delivery with the obstetrician standing). Some models offer a low position at 550 mm for patients who struggle with higher transfer heights.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-2854\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-echo-scaled-1920w.webp\" alt=\"Gynecology examination and procedure table with leg supports showing section articulation\" width=\"1920\" height=\"1440\" loading=\"lazy\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-echo-scaled-1920w.webp 1920w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-echo-scaled-1920w-300x225.webp 300w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-echo-scaled-1920w-1024x768.webp 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-echo-scaled-1920w-768x576.webp 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-echo-scaled-1920w-1536x1152.webp 1536w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-mechanical-operating-table-product-photo-echo-scaled-1920w-16x12.webp 16w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<h2>Lithotomy Positioning: Critical for Safe Delivery<\/h2>\n<p>The lithotomy position is the most common delivery position worldwide, and the obstetric table must support it safely and comfortably. Key requirements include:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Leg stirrups or candy-cane supports<\/strong> \u2014 must be adjustable for patient height and allow rapid release in emergencies<\/li>\n<li><strong>Perineal access<\/strong> \u2014 the seat section should split or retract to expose the perineum without requiring full leg elevation<\/li>\n<li><strong>Pressure distribution<\/strong> \u2014 calf and thigh supports must prevent common peroneal nerve compression during prolonged positioning<\/li>\n<\/ul>\n<p>The <a href=\"https:\/\/www.who.int\/health-topics\/maternal-health\" rel=\"noopener\" target=\"_blank\">WHO maternal health guidelines<\/a> emphasize that proper positioning during labor reduces the duration of the second stage and decreases the incidence of instrumental delivery. The table&#8217;s positioning capabilities directly support these clinical outcomes.<\/p>\n<h2>Mattress Selection for Obstetric Tables<\/h2>\n<p>The mattress is not an afterthought \u2014 it affects patient comfort during prolonged labor, infection control, and the table&#8217;s ability to maintain position under load. Key considerations:<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:1.5em 0;\">\n<thead>\n<tr style=\"background:#f0f4f8;\">\n<th style=\"padding:10px;border:1px solid #ddd;text-align:left;\">Mattress Type<\/th>\n<th style=\"padding:10px;border:1px solid #ddd;text-align:left;\">Advantages<\/th>\n<th style=\"padding:10px;border:1px solid #ddd;text-align:left;\">Considerations<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding:10px;border:1px solid #ddd;\">Polyurethane Foam<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">Firm support, easy to clean, cost-effective<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">Less pressure redistribution for long labors<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border:1px solid #ddd;\">Memory Foam<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">Excellent pressure redistribution<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">Softer, may affect section articulation precision<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border:1px solid #ddd;\">Gel-Overlay<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">Best pressure relief, temperature regulation<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">Higher cost, heavier, requires specific sizing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For obstetric tables, polyurethane foam remains the most common choice due to its balance of firmness (needed during active pushing) and cleanability (critical for infection control between patients). The <a href=\"\/hospital-bed-mattress-pressure-injury-prevention\/\">mattress pressure injury prevention guide<\/a> covers the clinical evidence behind mattress selection for prolonged positioning.<\/p>\n<h2>Fluid Management and Infection Control<\/h2>\n<p>Delivery generates significant fluid \u2014 amniotic fluid, blood, and irrigation. The obstetric table must manage this effectively:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Fluid collection channels<\/strong> \u2014 grooved tabletop surfaces direct fluid toward a collection basin<\/li>\n<li><strong>Removable perineal section<\/strong> \u2014 allows direct access for drainage and cleaning<\/li>\n<li><strong>Seamless mattress covers<\/strong> \u2014 welded (not stitched) seams prevent fluid ingress and bacterial colonization<\/li>\n<li><strong>Chemical resistance<\/strong> \u2014 all surfaces must withstand hospital-grade disinfectants including chlorine-based and hydrogen peroxide solutions<\/li>\n<\/ul>\n<p>The <a href=\"https:\/\/www.ecdc.europa.eu\/en\" rel=\"noopener\" target=\"_blank\">ECDC guidelines<\/a> on healthcare-associated infection prevention emphasize that equipment design plays a foundational role in reducing cross-contamination risk between patients.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-2904\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-operating-table-factory-photo-hotel-1920w.webp\" alt=\"Obstetric table production line showing quality control and assembly process\" width=\"1920\" height=\"1920\" loading=\"lazy\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-operating-table-factory-photo-hotel-1920w.webp 1920w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-operating-table-factory-photo-hotel-1920w-300x300.webp 300w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-operating-table-factory-photo-hotel-1920w-1024x1024.webp 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-operating-table-factory-photo-hotel-1920w-150x150.webp 150w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-operating-table-factory-photo-hotel-1920w-768x768.webp 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-operating-table-factory-photo-hotel-1920w-1536x1536.webp 1536w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-operating-table-factory-photo-hotel-1920w-12x12.webp 12w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<h2>Accessories That Improve Clinical Workflow<\/h2>\n<p>Beyond the base table, several accessories enhance the obstetric table&#8217;s clinical utility:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Lithotomy stirrup set<\/strong> \u2014 adjustable, quick-release leg supports for dorsal lithotomy positioning<\/li>\n<li><strong>Arm boards<\/strong> \u2014 hinged or removable for IV access and blood pressure monitoring during labor<\/li>\n<li><strong>Anesthesia screen mount<\/strong> \u2014 for epidural or spinal anesthesia procedures<\/li>\n<li><strong>Infant warmer mount<\/strong> \u2014 rail clamp for attaching a neonatal radiant warmer to the table frame<\/li>\n<li><strong>Side rails<\/strong> \u2014 adjustable height rails for patient safety during labor movement<\/li>\n<\/ul>\n<p>When requesting quotations, ensure accessories are itemized separately so you can compare total cost of ownership across suppliers. The <a href=\"\/hospital-equipment-procurement-checklist\/\">procurement checklist<\/a> includes a template for capturing all accessory requirements in your RFQ.<\/p>\n<p>When your accessory list is complete, the <a href=\"\/products\/operating-tables\/\">Sanyang Medical operating table range<\/a> includes obstetric bed models with the section articulation, lithotomy accessories, and fluid management options described above.<\/p>\n<\/p>\n<h2>Procurement Decision Framework<\/h2>\n<p>For procurement teams evaluating obstetric table options, the decision typically comes down to three tiers:<\/p>\n<ol style=\"font-size:15px!important;\">\n<li><strong>Basic gynecology table<\/strong> \u2014 manual adjustment, 2-section, suitable for outpatient examination only. Lowest cost but limited clinical utility in a delivery suite.<\/li>\n<li><strong>Mid-range obstetric table<\/strong> \u2014 electric adjustment, 3-4 section, Trendelenburg capability. Suitable for standard vaginal delivery and minor gynecological procedures.<\/li>\n<li><strong>Premium delivery bed<\/strong> \u2014 electro-hydraulic, full articulation, integrated fluid management, accessory ecosystem. Designed for high-volume maternity units with diverse clinical needs.<\/li>\n<\/ol>\n<p>The <a href=\"\/turnkey-operating-room-equipment-package\/\">turnkey OR equipment package guide<\/a> explains how bundling the obstetric table with other delivery suite equipment (infant warmers, fetal monitors, surgical lights) can reduce total procurement cost and simplify installation coordination.<\/p>\n<p>For facilities planning a new maternity wing, the <a href=\"\/operating-room-suite-planning-rooms-flows-adjacencies\/\">OR suite planning guide<\/a> covers how to integrate the delivery suite into the overall departmental layout, including adjacencies with the operating theater for emergency cesarean sections.<\/p>\n<div class=\"faq-card\">\n<h3>What is the difference between an obstetric table and a delivery bed?<\/h3>\n<p>Functionally, they serve the same purpose. &#8220;Obstetric table&#8221; is the technical procurement term used in specifications and tenders, while &#8220;delivery bed&#8221; is the common clinical term. Both refer to a specialized table designed for labor management, vaginal delivery, and post-partum care with features like lithotomy positioning, Trendelenburg tilt, and fluid management.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>How much does an obstetric table cost?<\/h3>\n<p>Basic gynecology exam tables start from $1,500\u20133,000. Mid-range electric obstetric tables range from $4,000\u20138,000. Premium electro-hydraulic delivery beds with full accessory packages range from $8,000\u201315,000. Pricing varies by manufacturer, certification requirements, and included accessories.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>What certifications should an obstetric table have?<\/h3>\n<p>For international procurement, the table should carry CE marking (EU MDR 2017\/745, Class I or IIa depending on features) and ISO 13485 manufacturing certification. For specific markets, additional certifications may be required \u2014 FDA 510(k) for the US market, NMPA registration for China, and local free sale certificates for Middle East and African markets.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>Can an obstetric table be used for cesarean section?<\/h3>\n<p>While some obstetric tables can achieve sufficient flat positioning for emergency cesarean section, they are not designed as primary surgical tables. Facilities performing cesarean sections should have a dedicated operating table in the surgical theater. The obstetric table&#8217;s role is vaginal delivery and labor management.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>What maintenance does an obstetric table require?<\/h3>\n<p>Routine maintenance includes monthly inspection of articulation joints and locking mechanisms, quarterly lubrication of moving parts, annual electrical safety testing per IEC 60601-1, and immediate replacement of damaged mattress covers. The <a href=\"\/operating-table-rail-repair\/\">table rail repair guide<\/a> covers common maintenance issues with side rail clamps and mounting points.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the difference between an obstetric table and a delivery bed?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Functionally, they serve the same purpose. 'Obstetric table' is the technical procurement term used in specifications and tenders, while 'delivery bed' is the common clinical term. Both refer to a specialized table designed for labor management, vaginal delivery, and post-partum care with features like lithotomy positioning, Trendelenburg tilt, and fluid management.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How much does an obstetric table cost?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Basic gynecology exam tables start from $1,500\u20133,000. Mid-range electric obstetric tables range from $4,000\u20138,000. Premium electro-hydraulic delivery beds with full accessory packages range from $8,000\u201315,000. Pricing varies by manufacturer, certification requirements, and included accessories.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What certifications should an obstetric table have?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"For international procurement, the table should carry CE marking (EU MDR 2017\/745, Class I or IIa depending on features) and ISO 13485 manufacturing certification. For specific markets, additional certifications may be required \u2014 FDA 510(k) for the US market, NMPA registration for China, and local free sale certificates for Middle East and African markets.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can an obstetric table be used for cesarean section?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"While some obstetric tables can achieve sufficient flat positioning for emergency cesarean section, they are not designed as primary surgical tables. Facilities performing cesarean sections should have a dedicated operating table in the surgical theater. The obstetric table's role is vaginal delivery and labor management.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What maintenance does an obstetric table require?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Routine maintenance includes monthly inspection of articulation joints and locking mechanisms, quarterly lubrication of moving parts, annual electrical safety testing per IEC 60601-1, and immediate replacement of damaged mattress covers.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"name\": \"Obstetric Table Buying Guide: Delivery Beds for Maternity Suites\",\n  \"description\": \"Complete procurement guide for obstetric tables: specifications, lithotomy positioning, mattress selection, fluid management, accessories, and cost comparison across basic, mid-range, and premium delivery beds.\",\n  \"author\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Sanyang Medical\"\n  },\n  \"publisher\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Sanyang Medical\"\n  },\n  \"datePublished\": \"2026-08-10\",\n  \"dateModified\": \"2026-08-10\",\n  \"mainEntityOfPage\": {\n    \"@type\": \"WebPage\",\n    \"@id\": \"https:\/\/sanyangmedical.com\/obstetric-table-buying-guide\/\"\n  }\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"GeoCoordinates\",\n  \"name\": \"Sanyang Medical Equipment\",\n  \"description\": \"Obstetric table procurement specifications: 3-4 section articulation, 180kg+ load capacity, 650-900mm height range, -25 to +25 degree Trendelenburg. Key features include lithotomy positioning, fluid management channels, and polyurethane mattress compatibility.\"\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Maternity wards need a table that transitions between examination, delivery, and post-partum recovery \u2014 often within the same patient encounter. The obstetric table is the centerpiece of any delivery suite, and choosing the wrong model creates workflow bottlenecks, compromises patient positioning, and increases the risk of perineal injury during assisted delivery. This guide covers the &#8230; <a title=\"Obstetric Table Buying Guide: Delivery Beds for Maternity Suites\" class=\"read-more\" href=\"https:\/\/sanyangmedical.com\/fr\/obstetric-table-buying-guide\/\" aria-label=\"En savoir plus sur Obstetric Table Buying Guide: Delivery Beds for Maternity Suites\">Lire la suite<\/a><\/p>","protected":false},"author":1,"featured_media":1221,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_title":"Obstetric Table Buying Guide | Delivery Beds for Maternity","rank_math_description":"Complete procurement guide for obstetric tables: specifications, lithotomy positioning, mattress selection, fluid management, and cost comparison across tiers.","rank_math_focus_keyword":"obstetric table","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_yoast_wpseo_focuskw":"","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":"","footnotes":""},"categories":[108],"tags":[],"class_list":["post-3705","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-surgical-equipment-guides"],"_links":{"self":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/3705","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/comments?post=3705"}],"version-history":[{"count":1,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/3705\/revisions"}],"predecessor-version":[{"id":3722,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/3705\/revisions\/3722"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/media\/1221"}],"wp:attachment":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/media?parent=3705"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/categories?post=3705"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/tags?post=3705"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}