{"id":3624,"date":"2026-08-05T15:22:02","date_gmt":"2026-08-05T15:22:02","guid":{"rendered":"https:\/\/sanyangmedical.com\/tt-vs-lc-payment-terms-medical-equipment\/"},"modified":"2026-08-09T17:28:27","modified_gmt":"2026-08-09T17:28:27","slug":"tt-vs-lc-payment-terms-medical-equipment","status":"publish","type":"post","link":"https:\/\/sanyangmedical.com\/fr\/tt-vs-lc-payment-terms-medical-equipment\/","title":{"rendered":"T\/T ou L\/C : Comment les distributeurs paient pour les importations d'\u00e9quipements"},"content":{"rendered":"<h2>What T\/T and L\/C Mean for Medical Equipment Buyers<\/h2>\n<p>Telegraphic transfer (T\/T) and letter of credit (L\/C) are the two payment methods most commonly used in medical equipment imports from China. Each protects different parties at different stages of the transaction, and choosing the wrong one for your order size or relationship stage can mean either unnecessary bank fees or unprotected exposure to supplier non-performance. For distributors placing their first order with a Chinese factory, the choice between T\/T and L\/C depends on order value, trust level, and the documentation requirements of the importing country.<\/p>\n<p>Sanyang Medical&#8217;s standard terms reflect the most common arrangement in the industry: 30 percent T\/T deposit to initiate production and 70 percent balance before shipment. For large orders, typically above 50,000 USD, the factory accepts L\/C at sight. These terms are not arbitrary. They balance the manufacturer&#8217;s need to cover material and labor costs during production with the buyer&#8217;s need to verify that goods are produced before releasing full payment.<\/p>\n<p>The 70 percent before shipment is exactly where a pre-shipment inspection sits: see our <a href=\"https:\/\/sanyangmedical.com\/pre-shipment-inspection-medical-equipment\/\">medical equipment pre-shipment inspection guide<\/a>.<\/p>\n<h2>T\/T Payment: How It Works and When to Use It<\/h2>\n<p>T\/T is a direct bank-to-bank wire transfer. The buyer instructs their bank to send funds to the supplier&#8217;s account. The transfer typically takes 1 to 3 business days and costs 20 to 50 USD in bank fees per transaction, regardless of the amount. For a 15,000 USD order of surgical lights and trolleys, the fee is negligible. For a 5,000 USD sample order, it is still manageable. This is why T\/T is the default method for orders under 50,000 USD and for repeat orders between parties who have an established relationship.<\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>T\/T (Telegraphic Transfer)<\/th>\n<th>L\/C (Letter of Credit)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Bank fees<\/td>\n<td>20 to 50 USD flat per transfer<\/td>\n<td>0.1% to 0.25% of transaction value<\/td>\n<\/tr>\n<tr>\n<td>Processing time<\/td>\n<td>1 to 3 business days<\/td>\n<td>5 to 10 business days<\/td>\n<\/tr>\n<tr>\n<td>Buyer protection<\/td>\n<td>None after funds leave account<\/td>\n<td>Bank guarantees payment only against shipping documents<\/td>\n<\/tr>\n<tr>\n<td>Supplier trust required<\/td>\n<td>High (funds sent before inspection)<\/td>\n<td>Moderate (bank verifies documents)<\/td>\n<\/tr>\n<tr>\n<td>Typical threshold<\/td>\n<td>Orders under 50,000 USD<\/td>\n<td>Orders above 50,000 USD or first-time buyers<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The risk with T\/T is clear: once the 70 percent balance is wired, the buyer has no recourse if the goods arrive damaged or incomplete. This is why the standard practice is to pay the balance only after a pre-shipment inspection or at minimum after receiving photos of the packaged goods and the container loading process. For guidance on what to check before releasing payment, the <a href=\"https:\/\/sanyangmedical.com\/sample-orders-evaluate-medical-equipment\/\">sample order evaluation guide<\/a> covers inspection procedures that apply to both sample and production orders.<\/p>\n<h2>L\/C at Sight: How It Works and When to Use It<\/h2>\n<p>A <a href=\"https:\/\/2go.iccwbo.org\/explore-our-products\/books\/trade-finance\/ucp-600.html\" target=\"_blank\" rel=\"noopener\">letter of credit<\/a> shifts the payment risk from the buyer to the buyer&#8217;s bank. The buyer&#8217;s bank issues a document guaranteeing payment to the supplier upon presentation of a specified set of shipping documents: bill of lading, commercial invoice, packing list, certificate of origin, and any required certification documents. The bank, not the buyer, verifies that these documents match the L\/C terms exactly. If the supplier fails to ship or the documents do not match, the bank does not release payment.<\/p>\n<p>L\/C at sight means the bank pays the supplier immediately upon document presentation and verification. The cost is 0.1 to 0.25 percent of the transaction value, so for a 100,000 USD operating room equipment package, the fee ranges from 100 to 250 USD. For a 500,000 USD hospital project supply, it reaches 500 to 1,250 USD. This makes L\/C cost-effective only for larger orders where the flat T\/T fee savings do not compensate for the protection gained.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-electric-operating-table-product-photo-uniform-scaled-1024w.webp\" alt=\"Operating table prepared for export packing and container loading at the Sanyang Medical factory\" width=\"1024\" height=\"576\" \/><\/p>\n<h2>The 30\/70 Split: Why It Is the Industry Standard<\/h2>\n<p>The 30 percent deposit and 70 percent balance split exists for a specific reason. The 30 percent deposit covers the manufacturer&#8217;s material procurement costs: steel, ABS resin, LED modules, motors, and electronic components. Medical equipment manufacturing is not like consumer electronics where components are stocked in advance. Each order triggers a production run with materials purchased specifically for that order. Without the deposit, the factory would finance the buyer&#8217;s materials, which is unsustainable for a factory dealing with multiple simultaneous orders.<\/p>\n<p>The 70 percent balance before shipment protects the buyer. At this stage, the production is complete and the goods are packaged. The buyer can request pre-shipment photos, a third-party inspection, or even a video call to verify the production. Only after verification does the buyer release the balance. For Sanyang Medical, standard products like trolleys and examination lights complete in 3 to 7 days, while custom orders like OEM-branded pendants or beds with specific language interfaces take 15 to 20 days. The balance payment is due when production is complete, not when the order is placed.<\/p>\n<h2>Document Requirements for L\/C Transactions<\/h2>\n<p>When using L\/C, the document set must be specified in the L\/C application. Medical equipment imports typically require more documentation than general consumer goods because of regulatory compliance. The following documents are standard for a medical equipment L\/C:<\/p>\n<ul>\n<li><strong>Bill of lading<\/strong>: Issued by the freight forwarder, confirms goods loaded on vessel.<\/li>\n<li><strong>Commercial invoice<\/strong>: Must match L\/C value exactly.<\/li>\n<li><strong>Packing list<\/strong>: Itemized weight, dimensions, and carton count.<\/li>\n<li><strong>Certificate of origin<\/strong>: Issued by CCPIT or local chamber of commerce.<\/li>\n<li><strong>CE certificate<\/strong>: Copy of the CE marking certificate for regulated products.<\/li>\n<li><strong>Free Sale Certificate<\/strong>: With <a href=\"https:\/\/www.hcch.net\/en\/instruments\/conventions\/full-text\/?cid=41\" target=\"_blank\" rel=\"noopener\">Apostille<\/a> for countries requiring it.<\/li>\n<li><strong>ISO 13485 certificate<\/strong>: Copy of the factory&#8217;s quality management certification.<\/li>\n<\/ul>\n<p>Any discrepancy between the L\/C terms and the presented documents gives the buyer&#8217;s bank grounds to refuse payment. This is why suppliers prefer T\/T for orders where the document complexity is high and the value is moderate. Sanyang Medical provides an Apostille document package including Free Sale Certificate with CCPIT authentication, which simplifies the L\/C document preparation for buyers in countries that require apostilled documents for medical device registration. For more on the documentation requirements, the <a href=\"https:\/\/sanyangmedical.com\/incoterms-medical-equipment-import\/\">Incoterms for medical equipment imports guide<\/a> covers the shipping and documentation chain in detail.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-baby-trolley-factory-photo-charlie-1024w.webp\" alt=\"Finished medical trolleys staged in factory warehouse ready for export shipping\" width=\"1024\" height=\"768\" \/><\/p>\n<h2>Decision Framework: Which Payment Method for Your Order<\/h2>\n<p>The choice between T\/T and L\/C should be driven by three factors: order value, relationship maturity, and regulatory requirements. For a distributor placing a first order below 50,000 USD with a new supplier, T\/T with a pre-shipment inspection is the practical choice. The L\/C fees would consume a disproportionate share of a smaller order, and the document complexity adds delay without proportional benefit.<\/p>\n<table>\n<thead>\n<tr>\n<th>Order Scenario<\/th>\n<th>Recommended Method<\/th>\n<th>Rationale<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>First-time sample order under 5,000 USD<\/td>\n<td>T\/T 100% advance<\/td>\n<td>Bank fees for L\/C exceed the proportional benefit; sample orders are low risk<\/td>\n<\/tr>\n<tr>\n<td>First production order 5,000 to 50,000 USD<\/td>\n<td>T\/T 30\/70 with inspection<\/td>\n<td>Standard split; balance released after pre-shipment photos or third-party check<\/td>\n<\/tr>\n<tr>\n<td>Repeat order under 50,000 USD<\/td>\n<td>T\/T 30\/70<\/td>\n<td>Established trust; L\/C adds cost without value<\/td>\n<\/tr>\n<tr>\n<td>Large order 50,000 to 200,000 USD<\/td>\n<td>L\/C at sight or T\/T 30\/70<\/td>\n<td>L\/C provides bank-level document verification; T\/T if relationship is established<\/td>\n<\/tr>\n<tr>\n<td>Hospital project supply above 200,000 USD<\/td>\n<td>L\/C at sight<\/td>\n<td>Bank protection warranted; buyer&#8217;s bank verifies all shipping documents<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For new distributors evaluating suppliers, the <a href=\"https:\/\/sanyangmedical.com\/medical-equipment-distributor-guide-china\/\">distributor guide for working with Chinese manufacturers<\/a> covers the broader relationship setup including territory agreements and exclusivity terms that often accompany large-order payment negotiations.<\/p>\n<h2>Common Payment Disputes and How to Avoid Them<\/h2>\n<p>Three payment disputes recur in medical equipment trade. First, the buyer pays the 30 percent deposit but the supplier delays production beyond the stated lead time. The fix: include a production timeline in the proforma invoice with a penalty clause for delay. Sanyang Medical&#8217;s standard lead times are 3 to 7 days for standard products and 15 to 20 days for custom, and these should appear in the purchase order.<\/p>\n<p>Second, the buyer withholds the 70 percent balance demanding modifications after production is complete. This is a scope change, not a payment issue. The fix: freeze the specification at deposit stage. Any post-production changes are billed as a new work order, not held against the existing balance.<\/p>\n<p>Third, L\/C documents are rejected for minor discrepancies like a misspelled product description or a weight difference of 1 kg between the packing list and the bill of lading. The fix: have the supplier send a draft document set for buyer approval before the L\/C expiry date. For buyers who need to understand the financing alternatives beyond T\/T and L\/C, the <a href=\"https:\/\/sanyangmedical.com\/hospital-equipment-financing-leasing-guide\/\">equipment financing and leasing guide<\/a> covers buy-versus-lease decisions and bank financing options.<\/p>\n<h2>How Sanyang Medical Structures Payment for Different Buyers<\/h2>\n<p>Sanyang Medical serves five buyer types across its export regions: distributors in North America and Europe, EPC contractors in the Middle East, ministry and NGO tender buyers in Africa, private hospital investors in Southeast Asia, and private-label OEM customers in Eastern Europe. Each type has different payment constraints. Ministry tenders often require L\/C because government procurement rules mandate bank-guaranteed payment. Distributors placing mixed-product orders typically use T\/T because the order value is moderate and the relationship is ongoing. OEM private-label projects with custom tooling use T\/T with a separate tooling deposit because L\/C does not accommodate intangible cost items well.<\/p>\n<p>For buyers ready to discuss specific order terms, <a href=\"https:\/\/sanyangmedical.com\/solutions\/oem-odm-localization\/\">Sanyang Medical&#8217;s OEM and localization solutions<\/a> page explains the customization capabilities that affect payment structuring, and the <a href=\"https:\/\/sanyangmedical.com\/moq-lead-times-chinese-factories\/\">MOQ and lead times guide<\/a> provides the production timeline context that should accompany any payment negotiation.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3>Is T\/T safe for a first order with a Chinese manufacturer?<\/h3>\n<p>T\/T with a 30\/70 split is the industry standard for first orders under 50,000 USD. The 70 percent balance is released only after production is complete and verified through pre-shipment photos or a third-party inspection. The 30 percent deposit is the manufacturer&#8217;s assurance that the buyer is committed.<\/p>\n<h3>When should I insist on L\/C instead of T\/T?<\/h3>\n<p>Use L\/C for orders above 50,000 USD with a new supplier, for government tenders requiring bank-guaranteed payment, or when the importing country&#8217;s customs requires document verification before clearing goods. L\/C fees of 0.1 to 0.25 percent are proportionate only for larger orders.<\/p>\n<h3>Can I negotiate a lower deposit than 30 percent?<\/h3>\n<p>The 30 percent deposit covers material procurement costs. Suppliers rarely go below 20 percent because they must purchase steel, electronics, and components before production starts. A supplier offering 10 percent deposit may not be manufacturing in-house or may be desperate for cash, which signals risk.<\/p>\n<h3>What documents does Sanyang Medical provide for L\/C?<\/h3>\n<p>Sanyang Medical provides bill of lading, commercial invoice, packing list, certificate of origin (CCPIT), CE certificate, ISO 13485 certificate, and Free Sale Certificate with Apostille. The document set is prepared in draft form for buyer approval before the L\/C expiry date.<\/p>\n<p><script type=\"application\/ld+json\" id=\"evo301-geo-ai-block\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"name\": \"T\/T vs L\/C: How Distributors Pay for Equipment Imports\",\n  \"description\": \"T\/T (telegraphic transfer) with 30% deposit and 70% balance before shipment is the standard payment method for medical equipment orders under 50,000 USD. L\/C at sight, costing 0.1% to 0.25% of transaction value, is used for orders above 50,000 USD and government tenders requiring bank-guaranteed payment. Sanyang Medical accepts both terms, with standard lead times of 3-7 days for standard products and 15-20 days for custom orders.\",\n  \"data_statements\": [\n    \"Sanyang Medical standard payment terms are 30% T\/T deposit and 70% balance before shipment.\",\n    \"L\/C at sight is accepted for large orders, typically above 50,000 USD.\",\n    \"T\/T bank fees are 20 to 50 USD per transfer; L\/C fees are 0.1% to 0.25% of transaction value.\",\n    \"Standard lead time is 3-7 days for standard products, 15-20 days for custom products.\",\n    \"Sanyang Medical provides CE, ISO 13485, Free Sale Certificate with CCPIT and Apostille documentation.\"\n  ],\n  \"qa_concise\": [\n    {\"question\": \"Is T\/T safe for first orders?\", \"answer\": \"T\/T with 30\/70 split is standard; balance released after pre-shipment inspection for orders under 50,000 USD.\"},\n    {\"question\": \"When to use L\/C instead of T\/T?\", \"answer\": \"For orders above 50,000 USD, new suppliers, or government tenders requiring bank-guaranteed payment.\"},\n    {\"question\": \"Can I negotiate below 30% deposit?\", \"answer\": \"Rarely below 20%. The deposit covers material procurement; lower deposits may signal supplier cash flow issues.\"}\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is T\/T safe for a first order with a Chinese manufacturer?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"T\/T with a 30\/70 split is the industry standard for first orders under 50,000 USD. The 70 percent balance is released only after production is complete and verified through pre-shipment photos or a third-party inspection.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"When should I insist on L\/C instead of T\/T?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use L\/C for orders above 50,000 USD with a new supplier, for government tenders requiring bank-guaranteed payment, or when customs requires document verification before clearing goods.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I negotiate a lower deposit than 30 percent?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Suppliers rarely go below 20 percent because they must purchase materials before production. A supplier offering 10 percent deposit may signal cash flow risk.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What documents does Sanyang Medical provide for L\/C?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Bill of lading, commercial invoice, packing list, certificate of origin (CCPIT), CE certificate, ISO 13485 certificate, and Free Sale Certificate with Apostille.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>What T\/T and L\/C Mean for Medical Equipment Buyers Telegraphic transfer (T\/T) and letter of credit (L\/C) are the two payment methods most commonly used in medical equipment imports from China. Each protects different parties at different stages of the transaction, and choosing the wrong one for your order size or relationship stage can mean &#8230; <a title=\"T\/T ou L\/C : Comment les distributeurs paient pour les importations d&#039;\u00e9quipements\" class=\"read-more\" href=\"https:\/\/sanyangmedical.com\/fr\/tt-vs-lc-payment-terms-medical-equipment\/\" aria-label=\"En savoir plus sur T\/T vs L\/C : Comment les distributeurs paient les importations d&#039;\u00e9quipements\">Lire la suite<\/a><\/p>","protected":false},"author":1,"featured_media":2776,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_title":"","rank_math_description":"","rank_math_focus_keyword":"","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_yoast_wpseo_focuskw":"","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":"","footnotes":""},"categories":[110],"tags":[],"class_list":["post-3624","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-procurement-sourcing"],"_links":{"self":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/3624","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/comments?post=3624"}],"version-history":[{"count":2,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/3624\/revisions"}],"predecessor-version":[{"id":3694,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/3624\/revisions\/3694"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/media\/2776"}],"wp:attachment":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/media?parent=3624"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/categories?post=3624"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/tags?post=3624"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}