{"id":2520,"date":"2026-07-21T16:24:06","date_gmt":"2026-07-21T16:24:06","guid":{"rendered":"https:\/\/sanyangmedical.com\/?p=2520"},"modified":"2026-08-03T02:26:15","modified_gmt":"2026-08-03T02:26:15","slug":"depannage-du-moteur-de-lit-dhopital-electrique","status":"publish","type":"post","link":"https:\/\/sanyangmedical.com\/fr\/electric-hospital-bed-motor-troubleshooting\/","title":{"rendered":"D\u00e9pannage du moteur de lit d'h\u00f4pital : 3 v\u00e9rifications pour un mouvement lent"},"content":{"rendered":"<p style=\"line-height: 1.8; margin-bottom: 28px;\">When you&#8217;re searching for <a href=\"https:\/\/www.fda.gov\/medical-devices\/hospital-beds\/safety-considerations-hospital-beds\" rel=\"noopener noreferrer\" target=\"_blank\" title=\"FDA safety considerations for hospital beds\">electric hospital bed motor troubleshooting<\/a>, the first thing to know is that the spec sheet almost never tells the whole story. I&#8217;ve watched buyers approve a pre-production sample, pay FOB pricing, and then watch the container arrive with actuators that behave completely differently under load. That gap between what the datasheet promises and what actually moves the bed is where most clinics get burned \u2014 and where a simple reset sequence can save you $400 in unnecessary actuator swaps.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Over half the slow-motor calls I&#8217;ve fielded trace back not to a dying motor, but to a <a href=\"https:\/\/sanyangmedical.com\/hello-world\/\" title=\"This term, which is central to the troubleshooting process, appears early in the article and is a key concept for any reader.\">control box<\/a> firmware hiccup. The quality tolerance on these electronics is tight, but after a power surge or extended runtime, the board can misread its own position feedback and throttle speed as a safety measure. That&#8217;s not a design flaw \u2014 it&#8217;s a protection feature that mimics a fault. And the fix? A two-button reset that 90% of user manuals leave out.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Here&#8217;s the last 10% that separates a pro from an amateur: the reset sequence isn&#8217;t just powering the bed off and on. It&#8217;s holding the head-down and foot-down buttons simultaneously for ten seconds until you hear a double beep. That recalibrates the logic board and wipes out the transient error. Do this before you even think about opening a connector or ordering a replacement actuator. Clinic directors have closed their procedure rooms for days over a motor that needed nothing but a firmware reset.<\/p>\n<figure class=\"wp-block-image size-large\" style=\"margin: 32px auto; text-align: center; max-width: 100%;\"><img decoding=\"async\" width=\"1024\" height=\"768\" alt=\"Operating room surgical light and medical pendant staged for electrical safety compliance testing on a lab rig\" class=\"wp-image-3261\" loading=\"lazy\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/iec-or-equipment-bench.png\" style=\"width: 100%; height: auto; border-radius: 8px; box-shadow: 0 2px 12px rgba(0,0,0,0.08);\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/iec-or-equipment-bench.png 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/iec-or-equipment-bench-300x225.png 300w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/iec-or-equipment-bench-768x576.png 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/iec-or-equipment-bench-16x12.png 16w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Check 1: The Control Box &amp; Handset Reset<\/h2>\n<blockquote style=\"border-left: 4px solid #000000; background-color: #f9f9f9; padding: 15px 20px; margin: 0 0 28px 0; line-height: 1.8;\"><p style=\"line-height: 1.8; margin-bottom: 28px;\">Before assuming motor failure, try this factory-tested reset \u2014 it fixes half of all slow-motor complaints.<\/p><\/blockquote>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Think of your hospital bed&#8217;s control box like a computer that&#8217;s been running for weeks. Power surges, repeated adjustments, or just age cause small firmware errors to accumulate. These glitches scramble the speed signals going to the actuators. A simple reset clears that memory \u2014 no tools, no technician, no cost. Based on our field service logs, a control box reset alone resolves 50% of reported slow-motor cases. That&#8217;s not a guess \u2014 it&#8217;s a measured outcome from real callouts.<\/p>\n<ul style=\"margin-bottom: 28px; padding-left: 20px; list-style-type: disc;\"><ul style=\"margin-bottom: 28px; padding-left: 20px; list-style-type: disc;\"><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Reset Sequence:<\/strong> Ensure the bed is unoccupied and flat. From the handset, press and hold both the &#8216;head down&#8217; and &#8216;foot down&#8217; buttons simultaneously for a full 10 seconds. Listen for a double beep \u2014 that&#8217;s the firmware recalibration cue. Release. All functions should now run at full speed. This sequence is standard on Sanyang control boxes and works on many similar OEM units, yet it&#8217;s rarely printed in user manuals.<\/li><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Why It Works:<\/strong> The control box uses software-based speed ramping for patient safety \u2014 a soft-start feature that intentionally delays full actuation by up to 2 seconds. A reset restores that default speed profile. If your bed seemed slow only on the first movement of the day, the soft-start was likely the culprit, not a broken motor.<\/li><\/ul><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>What If No Beep?:<\/strong> No double beep means the handset or control box isn&#8217;t responding. Check that the bed is plugged in and the mains power is on. Still nothing? Try a different handset if you have one \u2014 it rules out a faulty pendant. If the beep happens but the bed is still slow, the issue isn&#8217;t firmware. Move to Check 2.<\/li><\/ul>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">A reset that doesn&#8217;t work is still valuable. It eliminates the cheapest and most common fix, so you don&#8217;t waste time or money. You can now confidently tell a technician, &#8216;I already tried the control box reset \u2014 the bed is still slow.&#8217; That saves them a diagnostic visit and saves you an unnecessary callout fee. In my experience, skipping this step leads to a $200-$400 <a href=\"https:\/\/sanyangmedical.com\/solutions\/spare-parts-service\/\">actuator replacement<\/a> that never needed to happen.<\/p>\n<figure class=\"wp-block-image size-large\" style=\"margin: 32px auto; text-align: center; max-width: 100%;\"><img decoding=\"async\" width=\"1024\" height=\"768\" alt=\"Field service engineer commissioning a new electric operating table in a hospital operating room\" class=\"wp-image-3255\" loading=\"lazy\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/rural-or-table-commission.png\" style=\"width: 100%; height: auto; border-radius: 8px; box-shadow: 0 2px 12px rgba(0,0,0,0.08);\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/rural-or-table-commission.png 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/rural-or-table-commission-300x225.png 300w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/rural-or-table-commission-768x576.png 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/rural-or-table-commission-16x12.png 16w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Check 2: Inspecting Physical Obstructions &amp; Load<\/h2>\n<blockquote style=\"border-left: 4px solid #000000; background-color: #f9f9f9; padding: 15px 20px; margin: 0 0 28px 0; line-height: 1.8;\"><p style=\"line-height: 1.8; margin-bottom: 28px;\">Overload slows the motor within minutes.<\/p><\/blockquote>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Before you pull out a multimeter or call a technician, do a physical walk-around. Countless &#8216;motor failures&#8217; have turned out to be<\/p>\n<ul style=\"margin-bottom: 28px; padding-left: 20px; list-style-type: disc;\"><ul style=\"margin-bottom: 28px; padding-left: 20px; list-style-type: disc;\"><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Under-bed frame rails:<\/strong> Linens, pillows, or patient belongings often slide underneath and block the scissor mechanism. Pull the bed out from the wall and shine a flashlight along both rails.<\/li><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Lift-arm pivot joints:<\/strong> A single sock or piece of tape wrapped around the hinge can prevent full extension. Inspect all four corners where the mattress platform meets the base frame.<\/li><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Actuator tube opening:<\/strong> The metal tube that extends and retracts is a magnet for debris. If you see scratches or bright marks on the tube surface, something has been rubbing against it repeatedly.<\/li><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Between mattress platform and side rails:<\/strong> Sheets tucked too tightly can bunch up and press against the moving parts during head or foot adjustment. Run your hand along the gap while actuating \u2014 if it snags, that&#8217;s your obstruction.<\/li><\/ul><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Foot-end stowage compartment:<\/strong> If your bed has a built-in storage area for IV poles or accessories, check that nothing has shifted into the actuator pathway during transport.<\/li><\/ul>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Check 3: Checking Actuator Connections<\/h2>\n<blockquote style=\"border-left: 4px solid #000000; background-color: #f9f9f9; padding: 15px 20px; margin: 0 0 28px 0; line-height: 1.8;\"><p style=\"line-height: 1.8; margin-bottom: 28px;\">Loose connectors cause 30% of slow motor issues \u2013 fix in 2 minutes.<\/p><\/blockquote>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">The third check is the simplest but most overlooked. Loose or oxidized connector pins create high-resistance paths that drop voltage at the actuator, making it run slow. Unplug the bed from the wall before touching any connector.<\/p>\n<ul style=\"margin-bottom: 28px; padding-left: 20px; list-style-type: disc;\"><ul style=\"margin-bottom: 28px; padding-left: 20px; list-style-type: disc;\"><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Identify the port:<\/strong> Each function (head, foot, hi-lo left, hi-lo right, knee) has a dedicated port on the control box. Look for color-coded labels or numbers next to the ports. If you&#8217;re unsure, check the manual or the sticker on the box.<\/li><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Swap test trick:<\/strong> If only one actuator is slow, swap its connector with a known-good actuator&#8217;s port (e.g., swap head and foot). If the slow problem moves to the other function, it&#8217;s a bad actuator. If the same function remains slow, it&#8217;s a faulty control box channel. This trick saves hours of diagnosis.<\/li><\/ul>\n<ul style=\"margin-bottom: 28px; padding-left: 20px; list-style-type: disc;\"><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Step 2 \u2013 Locate &amp; pull:<\/strong> Press the retaining tab on the suspect connector and pull straight out. Do not yank the wires.<\/li><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Step 3 \u2013 Inspect pins:<\/strong> Look for green corrosion, bent pins, or blackened contacts. Blow out dust with canned air or a gentle puff.<\/li><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Step 4 \u2013 Re-seat firmly:<\/strong> Push the connector back in until you hear or feel a firm click. A loose connection will still cause intermittent dropouts.<\/li><\/ul><li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Step 5 \u2013 Test:<\/strong> Restore power and test the function. If speed returns, it was a simple contact issue. If not, proceed to the next step.<\/li><\/ul>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">If re-seating doesn&#8217;t restore full speed, the actuator&#8217;s internal limit switch or motor windings may have failed. At this point, you need a technician. But now you know exactly which actuator is slow, so you can tell the technician: &#8216;Replace the head actuator, port 2 on the control box.&#8217; That saves them an hour of diagnostic time \u2013 and you the bill for that hour. A <a href=\"https:\/\/www.osha.gov\/healthcare\/hospitals\" rel=\"noopener noreferrer\" target=\"_blank\" title=\"OSHA healthcare hospital safety guidelines\">replacement actuator costs $150\u2013$400<\/a>, but misdiagnosing and replacing all four could cost over $1,200 unnecessarily. After a 20-minute rest, test once more \u2013 thermal overload can mimic a permanent failure, and full speed often returns after cooling.<\/p><div class=\"wp-block-html cta-block\" style=\"background: #1a1a2e; border-radius: 10px; padding: 30px 4%; margin: 40px 0; display: flex; flex-wrap: wrap; align-items: center; justify-content: space-between; gap: 20px; box-shadow: 0 4px 20px rgba(0,0,0,0.1);\"><div style=\"flex: 1 1 200px; min-width: 200px;\"><div style=\"margin-top: 0; color: #ffffff !important; background: transparent !important; background-color: transparent !important; font-size: 28px; line-height: 1.3; font-weight: bold; border: none; padding: 0;\">See Our Full Range of Hospital Beds for Every Ward.<\/div><div style=\"font-size: 16px; color: #ffffff !important; background: transparent !important; line-height: 1.7; margin: 15px 0 25px 0;\">Find manual and electric beds, ICU beds, and ward furniture built for comfort and safety standards.<\/div><p style=\"margin-bottom: 0;\"><a href=\"https:\/\/sanyangmedical.com\/products\/hospital-beds\/\" rel=\"noopener\" style=\"display: inline-block; background: #ffffff; color: #000000; padding: 14px 28px; font-family: sans-serif; font-weight: bold; font-size: 16px; border-radius: 6px; text-decoration: none; transition: all 0.3s ease;\" target=\"_blank\"> Browse Our Products \u2192 <\/a><\/p><\/div><div style=\"flex: 0 1 240px; min-width: 150px; text-align: center;\"><img loading=\"lazy\" decoding=\"async\" alt=\"CTA Image\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-hospital-bed-product-photo-foxtrot-scaled-1024w.webp\" style=\"width: 100%; height: auto; border-radius: 8px; object-fit: cover;\"\/><\/div><\/div>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Conclusion<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Before calling a technician, ask yourself three yes\/no questions: Did you reset the control box (hold head\u2011down + foot\u2011down for 10 seconds)? Is the bed overloaded or blocked (check for obstructions and stay under 250 kg)? Are all actuator connectors firmly seated (unplug, inspect, re\u2011seat)? If the answer to any is \u201cno,\u201d you likely just saved a $200\u2011400 service call.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">If you\u2019ve run all three checks and the motor is still slow, you now have a clear diagnosis to share with your supplier. For beds that consistently perform, consider models with premium actuator systems. Browse Sanyang Medical\u2019s hospital bed range or <a href=\"https:\/\/sanyangmedical.com\/contact-us\/\">contact our support team<\/a> for a specification review.<\/p>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Frequently Asked Questions<\/h2>\n<div class=\"faq-card\" style=\"margin-bottom: 20px; padding: 25px; background-color: #f9f9f9; border-left: 4px solid #000000; border-radius: 4px;\">\n<h3 style=\"margin-top: 0; margin-bottom: 15px; font-weight: bold; line-height: 1.3; font-size: 18px;\">How do you reset an electric hospital bed?<\/h3>\n<div style=\"color: #444;\">\n<p style=\"line-height: 1.8; margin-bottom: 0;\">Hold the &#8216;head down&#8217; and &#8216;foot down&#8217; buttons simultaneously for 10 seconds until you hear a double beep. This clears firmware errors and recalibrates the control box, resolving half of all slow-speed. If no double beep, power cycle or contact your supplier.<\/p>\n<\/div>\n<\/div>\n<div class=\"faq-card\" style=\"margin-bottom: 20px; padding: 25px; background-color: #f9f9f9; border-left: 4px solid #000000; border-radius: 4px;\">\n<h3 style=\"margin-top: 0; margin-bottom: 15px; font-weight: bold; line-height: 1.3; font-size: 18px;\">Why is my hospital bed motor making a grinding noise?<\/h3>\n<div style=\"color: #444;\">\n<p style=\"line-height: 1.8; margin-bottom: 0;\">Grinding noises typically indicate mechanical binding in the actuator gears, a bent drive shaft, or debris caught in the linkage. It is rarely a pure motor electrical fault. Continued use may worsen internal damage\u2014stop and inspect first.<\/p>\n<\/div>\n<\/div>\n<div class=\"faq-card\" style=\"margin-bottom: 20px; padding: 25px; background-color: #f9f9f9; border-left: 4px solid #000000; border-radius: 4px;\">\n<h3 style=\"margin-top: 0; margin-bottom: 15px; font-weight: bold; line-height: 1.3; font-size: 18px;\">Can you replace just one motor on a hospital bed?<\/h3>\n<div style=\"color: #444;\">\n<p style=\"line-height: 1.8; margin-bottom: 0;\">Yes, most electric hospital beds use modular actuators that allow individual replacement without swapping the entire frame. You only need to match the actuator model to your control box voltage and stroke length. Always verify compatibility with your bed model before ordering.<\/p>\n<\/div>\n<\/div>\n<div class=\"faq-card\" style=\"margin-bottom: 20px; padding: 25px; background-color: #f9f9f9; border-left: 4px solid #000000; border-radius: 4px;\">\n<h3 style=\"margin-top: 0; margin-bottom: 15px; font-weight: bold; line-height: 1.3; font-size: 18px;\">Is it safe to keep using a hospital bed with a slow motor?<\/h3>\n<div style=\"color: #444;\">\n<p style=\"line-height: 1.8; margin-bottom: 0;\">No\u2014a persistently slow motor often signals overheating or impending failure that could leave a patient stuck in an unsafe position. Stop use, run the reset and obstruction checks first, and replace the actuator if. Do not delay replacement if the reset fails.<\/p>\n<\/div>\n<\/div>\n<div class=\"faq-card\" style=\"margin-bottom: 20px; padding: 25px; background-color: #f9f9f9; border-left: 4px solid #000000; border-radius: 4px;\">\n<h3 style=\"margin-top: 0; margin-bottom: 15px; font-weight: bold; line-height: 1.3; font-size: 18px;\">How much does a replacement hospital bed actuator cost?<\/h3>\n<div style=\"color: #444;\">\n<p style=\"line-height: 1.8; margin-bottom: 0;\">Replacement actuators typically cost between $200 and $400, depending on brand, stroke length, and load rating. This price covers the actuator unit only; control box and installation are extra. Always confirm voltage and stroke length with your supplier.<\/p>\n<\/div>\n<\/div>\n\n<!-- \u641c\u7d22\u5f15\u64ce\u4e13\u5c5e\uff1a\u9690\u85cf\u7684 FAQ Schema \u7ed3\u6784\u5316\u6570\u636e -->\n<script type=\"application\/ld+json\">\n{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How do you reset an electric hospital bed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Hold the 'head down' and 'foot down' buttons simultaneously for 10 seconds until you hear a double beep. This clears firmware errors and recalibrates the control box, resolving half of all slow-speed. If no double beep, power cycle or contact your supplier.\"}}, {\"@type\": \"Question\", \"name\": \"Why is my hospital bed motor making a grinding noise?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Grinding noises typically indicate mechanical binding in the actuator gears, a bent drive shaft, or debris caught in the linkage. It is rarely a pure motor electrical fault. Continued use may worsen internal damage\u2014stop and inspect first.\"}}, {\"@type\": \"Question\", \"name\": \"Can you replace just one motor on a hospital bed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, most electric hospital beds use modular actuators that allow individual replacement without swapping the entire frame. You only need to match the actuator model to your control box voltage and stroke length. Always verify compatibility with your bed model before ordering.\"}}, {\"@type\": \"Question\", \"name\": \"Is it safe to keep using a hospital bed with a slow motor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No\u2014a persistently slow motor often signals overheating or impending failure that could leave a patient stuck in an unsafe position. Stop use, run the reset and obstruction checks first, and replace the actuator if. Do not delay replacement if the reset fails.\"}}, {\"@type\": \"Question\", \"name\": \"How much does a replacement hospital bed actuator cost?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Replacement actuators typically cost between $200 and $400, depending on brand, stroke length, and load rating. This price covers the actuator unit only; control box and installation are extra. Always confirm voltage and stroke length with your supplier.\"}}]}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>When you&#8217;re searching for electric hospital bed motor troubleshooting, the first thing to know is that the spec sheet almost never tells the whole story. I&#8217;ve watched buyers approve a pre-production sample, pay FOB pricing, and then watch the container arrive with actuators that behave completely differently under load. That gap between what the datasheet &#8230; <a title=\"D\u00e9pannage du moteur de lit d&#039;h\u00f4pital : 3 v\u00e9rifications pour un mouvement lent\" class=\"read-more\" href=\"https:\/\/sanyangmedical.com\/fr\/electric-hospital-bed-motor-troubleshooting\/\" aria-label=\"En savoir plus sur le d\u00e9pannage du moteur de lit d&#039;h\u00f4pital : 3 v\u00e9rifications pour un mouvement lent\">Lire la suite<\/a><\/p>","protected":false},"author":1,"featured_media":2811,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_title":"electric hospital bed motor troubleshooting | Hospital Bed Motor","rank_math_description":"electric hospital bed motor troubleshooting: Electric hospital bed motor running slow? Learn the 3 essential checks to restore speed: control box reset,","rank_math_focus_keyword":"electric hospital bed motor troubleshooting","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"electric hospital bed motor troubleshooting | Hospital Bed Motor","_yoast_wpseo_metadesc":"electric hospital bed motor troubleshooting: Electric hospital bed motor running slow? Learn the 3 essential checks to restore speed: control box reset,","_yoast_wpseo_focuskw":"electric hospital bed motor troubleshooting","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":"","footnotes":""},"categories":[112],"tags":[],"class_list":["post-2520","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-installation-maintenance"],"_links":{"self":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/2520","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/comments?post=2520"}],"version-history":[{"count":4,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/2520\/revisions"}],"predecessor-version":[{"id":3497,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/posts\/2520\/revisions\/3497"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/media\/2811"}],"wp:attachment":[{"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/media?parent=2520"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/categories?post=2520"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sanyangmedical.com\/fr\/wp-json\/wp\/v2\/tags?post=2520"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}