{"id":3708,"date":"2026-08-11T14:42:49","date_gmt":"2026-08-11T14:42:49","guid":{"rendered":"https:\/\/sanyangmedical.com\/robotic-surgery-operating-room-equipment\/"},"modified":"2026-09-05T19:47:21","modified_gmt":"2026-09-05T19:47:21","slug":"robotic-surgery-operating-room-equipment","status":"publish","type":"post","link":"https:\/\/sanyangmedical.com\/es\/robotic-surgery-operating-room-equipment\/","title":{"rendered":"Robotic Surgery Adoption: What It Means for OR Equipment"},"content":{"rendered":"<p>Robotic surgery is no longer a niche capability reserved for flagship hospitals. As adoption accelerates across general surgery, urology, gynecology, and thoracic procedures, the operating room itself must evolve. Robotic systems change the spatial requirements, equipment layout, power demands, and staffing patterns of the OR \u2014 and procurement teams need to understand these changes before specifying new equipment packages.<\/p>\n<p>This guide examines what robotic surgery adoption means for OR equipment, from the physical footprint of the robot to the supporting infrastructure that traditional ORs were never designed to handle.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-3117\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-onyx-1-scaled-1920w.webp\" alt=\"Dual-arm surgical pendant with extended reach configured for hybrid operating room with robotic surgery system\" width=\"1920\" height=\"1440\" loading=\"lazy\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-onyx-1-scaled-1920w.webp 1920w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-onyx-1-scaled-1920w-300x225.webp 300w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-onyx-1-scaled-1920w-1024x768.webp 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-onyx-1-scaled-1920w-768x576.webp 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-onyx-1-scaled-1920w-1536x1152.webp 1536w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-onyx-1-scaled-1920w-16x12.webp 16w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<div class=\"yt-facade\" data-yt-id=\"SxLmH89HOEU\" role=\"button\" tabindex=\"0\" aria-label=\"Play video: Operating Room Set up in Robotic Pelvic Surgery\"><\/div>\n<p><script>(function(){var f=document.querySelector('.yt-facade');if(!f)return;f.innerHTML='<iframe style=\"width:100%;aspect-ratio:16\/9;border:none\" src=\"https:\/\/www.youtube.com\/embed\/'+f.dataset.ytId+'?autoplay=1\" title=\"YouTube video\" allow=\"accelerometer;autoplay;clipboard-write;encrypted-media;gyroscope;picture-in-picture\" allowfullscreen><\/iframe>';})();<\/script><\/p>\n<h2>The Physical Footprint: How Robots Change OR Spatial Requirements<\/h2>\n<p>A typical surgical robot (such as the da Vinci system) adds three major physical elements to the operating room:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Patient-side cart (manipulator arm)<\/strong> \u2014 positioned at the patient&#8217;s side, occupying approximately 1.5 m \u00d7 0.8 m of floor space. The arm&#8217;s range of motion requires clearance zones that prevent collision with other equipment.<\/li>\n<li><strong>Surgeon console<\/strong> \u2014 located 1\u20133 meters from the patient, where the surgeon sits to operate. This is a dedicated workstation that cannot be moved during the procedure.<\/li>\n<li><strong>Vision cart (electronics tower)<\/strong> \u2014 houses the processing units, insufflator, and energy platforms. Typically 0.6 m \u00d7 0.8 m, positioned near the patient-side cart.<\/li>\n<\/ul>\n<p>Together, these elements add approximately 3\u20134 m\u00b2 of dedicated equipment footprint to the OR. For a standard 40 m\u00b2 operating room, this represents a 7\u201310% reduction in usable floor space. The <a href=\"\/operating-room-suite-planning-rooms-flows-adjacencies\/\">OR suite planning guide<\/a> covers how to accommodate robotic systems in new construction versus retrofitting existing rooms.<\/p>\n<h3>Implications for OR Size<\/h3>\n<p>Many facilities building new robotic ORs specify 50\u201355 m\u00b2 rooms (compared to the traditional 35\u201340 m\u00b2) to maintain adequate circulation space for the surgical team, anesthesia equipment, and emergency access. The <a href=\"\/or-layout-planning-3d\/\">3D OR layout planning guide<\/a> provides templates for modeling robotic equipment placement before construction.<\/p>\n<h2>Operating Table Requirements for Robotic Surgery<\/h2>\n<p>Robotic surgery places unique demands on the operating table that standard tables cannot always meet:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Trendelenburg stability<\/strong> \u2014 robotic prostatectomy and pelvic surgery require steep Trendelenburg (30\u201345\u00b0 head-down). The table must maintain position stability with the robot&#8217;s manipulator arms attached, preventing drift that could damage tissue.<\/li>\n<li><strong>Rail compatibility<\/strong> \u2014 the robot&#8217;s patient-side cart docks to the table&#8217;s side rail. Rail specifications (width, profile, locking mechanism) must match the robot manufacturer&#8217;s requirements.<\/li>\n<li><strong>Carbon fiber tabletop<\/strong> \u2014 intraoperative imaging (fluoroscopy) is common in robotic procedures. A radiolucent tabletop allows imaging without repositioning the patient.<\/li>\n<li><strong>Load capacity with dynamic forces<\/strong> \u2014 the robot applies forces to the table through the manipulator arms during tissue manipulation. The table must absorb these forces without vibration or deflection.<\/li>\n<\/ul>\n<p>The <a href=\"\/radiolucent-carbon-fiber-operating-table-tops\/\">radiolucent carbon fiber table tops guide<\/a> explains how carbon fiber construction meets both the imaging and rigidity requirements for robotic surgery. The <a href=\"\/operating-table-hybrid-imaging-integration\/\">hybrid imaging integration guide<\/a> covers table specifications for combined robotic-fluoroscopic procedures.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-3097\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-keystone-1-scaled-1920w.webp\" alt=\"Surgical pendant pair flanking an operating table in a modern OR configured for advanced surgical procedures\" width=\"1920\" height=\"1440\" loading=\"lazy\" srcset=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-keystone-1-scaled-1920w.webp 1920w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-keystone-1-scaled-1920w-300x225.webp 300w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-keystone-1-scaled-1920w-1024x768.webp 1024w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-keystone-1-scaled-1920w-768x576.webp 768w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-keystone-1-scaled-1920w-1536x1152.webp 1536w, https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-medical-pendant-product-photo-keystone-1-scaled-1920w-16x12.webp 16w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<h2>Surgical Light and Pendant Requirements<\/h2>\n<p>Robotic surgery changes how surgical lights and pendants are positioned and specified:<\/p>\n<h3>Surgical Lights<\/h3>\n<p>With the surgeon operating from a console rather than directly over the patient, the surgical light&#8217;s role shifts from illuminating the surgeon&#8217;s direct view to providing ambient illumination for the assistant and scrub nurse. Key considerations:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li>The robot&#8217;s manipulator arms can cast shadows that the light must compensate for<\/li>\n<li>Camera-based illumination through the robot provides the surgeon&#8217;s primary view, reducing reliance on the overhead light<\/li>\n<li>Light positioning must avoid interference with the surgeon console and vision cart<\/li>\n<\/ul>\n<h3>Medical Pendants<\/h3>\n<p>Robotic ORs typically require additional pendant arms to supply the increased equipment load:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li>Dedicated pendant arm for the robot&#8217;s electronics (power + data)<\/li>\n<li>Standard pendant arms for anesthesia gas terminals and electrical outlets<\/li>\n<li>Endoscopy tower pendant for the laparoscopic camera system<\/li>\n<\/ul>\n<p>The <a href=\"\/medical-pendant-configuration-guide\/\">medical pendant configuration guide<\/a> covers how to calculate the total gas, electrical, and data requirements for a robotic OR pendant system. The <a href=\"\/single-vs-dual-arm-medical-pendant\/\">single vs dual arm pendant comparison<\/a> helps determine the optimal pendant setup for robotic workflows.<\/p>\n<h2>Power and Electrical Infrastructure<\/h2>\n<p>Robotic surgical systems draw significant electrical power \u2014 typically 3\u20135 kVA for the complete system including the patient cart, surgeon console, and vision tower. This is in addition to the existing OR electrical load from lights, anesthesia equipment, and monitoring systems.<\/p>\n<p>Electrical requirements for a robotic OR include:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Dedicated circuits<\/strong> \u2014 the robot should be on isolated circuits to prevent electromagnetic interference with other equipment<\/li>\n<li><strong>Uninterruptible Power Supply (UPS)<\/strong> \u2014 a power interruption during robotic surgery is more dangerous than in conventional surgery because the manipulator arms remain locked in position. A UPS with 15\u201330 minute runtime allows safe undocking.<\/li>\n<li><strong>Isolated power system<\/strong> \u2014 line isolation monitors (LIM) per IEC 60364-7-710 for the operating room&#8217;s electrical system<\/li>\n<li><strong>Data connectivity<\/strong> \u2014 the robot requires Ethernet for software updates, telemetry, and integration with the hospital&#8217;s surgical information system<\/li>\n<\/ul>\n<p>The <a href=\"\/surgical-light-backup-power-ups-guide\/\">surgical light UPS guide<\/a> covers backup power principles that apply equally to robotic system power protection.<\/p>\n<h2>Staffing and Workflow Changes<\/h2>\n<p>Robotic surgery changes the OR team composition and workflow:<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:1.5em 0;\">\n<thead>\n<tr style=\"background:#f0f4f8;\">\n<th style=\"padding:10px;border:1px solid #ddd;text-align:left;\">Role<\/th>\n<th style=\"padding:10px;border:1px solid #ddd;text-align:left;\">Traditional OR<\/th>\n<th style=\"padding:10px;border:1px solid #ddd;text-align:left;\">Robotic OR<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding:10px;border:1px solid #ddd;\">Surgeon<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">At the table, scrubbed<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">At console (may be in same room or remote)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border:1px solid #ddd;\">First Assistant<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">At the table<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">At the patient, managing instruments and suction<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border:1px solid #ddd;\">Scrub Nurse<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">At the back table<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">At the back table + instrument exchange at the port sites<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px;border:1px solid #ddd;\">Bedside Assistant<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">Not typically needed<\/td>\n<td style=\"padding:10px;border:1px solid #ddd;\">Required \u2014 manages instruments at patient side, assists with docking<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The addition of a bedside assistant means more people in the OR, which affects ventilation load, circulation space, and the positioning of equipment. The <a href=\"\/modular-vs-traditional-or\/\">modular vs traditional OR comparison<\/a> discusses how room design adapts to different staffing models.<\/p>\n<h2>Equipment Procurement for Robotic ORs<\/h2>\n<p>When building or upgrading to a robotic OR, the equipment package extends beyond the robot itself. A complete procurement list includes:<\/p>\n<ol style=\"font-size:15px!important;\">\n<li><strong>Robotic surgical system<\/strong> \u2014 capital cost typically $1.5\u20132.5 million plus annual maintenance contracts of $100,000\u2013170,000<\/li>\n<li><strong>Compatible operating table<\/strong> \u2014 with robotic docking rails, steep Trendelenburg capability, and radiolucent top ($30,000\u201380,000)<\/li>\n<li><strong>Enhanced surgical lights<\/strong> \u2014 repositioned for robotic workflow, often requiring additional ceiling supports ($15,000\u201340,000)<\/li>\n<li><strong>Additional pendant arms<\/strong> \u2014 for robot power\/data and endoscopy tower ($10,000\u201325,000 per arm)<\/li>\n<li><strong>UPS system<\/strong> \u2014 dedicated to the robotic system ($5,000\u201315,000)<\/li>\n<li><strong>Instrument sterilization containers<\/strong> \u2014 robotic instruments require specific sterilization trays and cycles ($3,000\u20138,000 per set)<\/li>\n<\/ol>\n<p>The <a href=\"\/turnkey-operating-room-equipment-package\/\">turnkey OR equipment guide<\/a> explains how bundling these items with your robot purchase can reduce total cost and ensure compatibility between components.<\/p>\n<p>For a complete robotic-ready buildout, the <a href=\"\/solutions\/turnkey-operating-room\/\">Sanyang Medical turnkey operating room solution<\/a> covers the full equipment scope &#8212; tables, pendants, lights, and power infrastructure &#8212; in a single coordinated package.<\/p>\n<p> The <a href=\"\/hospital-equipment-procurement-checklist\/\">procurement checklist<\/a> includes a robotic OR equipment section for specification capture.<\/p>\n<h2>Future-Proofing: What Adoption Trends Mean for OR Design<\/h2>\n<p>Robotic surgery adoption is accelerating. According to research published on <a href=\"https:\/\/www.frontiersin.org\/journals\/robotics-and-ai\" rel=\"noopener\" target=\"_blank\">Frontiers in Robotics and AI<\/a>, the global surgical robot market is projected to grow at over 15% annually through 2030. For facilities planning new construction or major renovations, this means:<\/p>\n<ul style=\"font-size:15px!important;\">\n<li><strong>Design at least one OR as robotic-ready<\/strong> \u2014 even if the robot is not purchased immediately, specifying the room with 50 m\u00b2 floor area, reinforced ceiling mounts, and enhanced electrical capacity avoids costly retrofits later.<\/li>\n<li><strong>Plan for multi-specialty robotic use<\/strong> \u2014 a single robotic system may serve urology, gynecology, and general surgery. The OR must accommodate the equipment and workflow variations across specialties.<\/li>\n<li><strong>Consider remote surgery infrastructure<\/strong> \u2014 while still emerging, 5G-enabled remote robotic surgery is being piloted. Network infrastructure (low-latency fiber, redundant connections) may become a future requirement.<\/li>\n<\/ul>\n<p>The <a href=\"\/digital-operating-room-trends\/\">digital OR trends guide<\/a> covers how networked ORs are evolving to support robotic integration, data capture, and AI-assisted surgical planning.<\/p>\n<p>For procurement teams evaluating the transition to robotic surgery, the <a href=\"\/or-equipment-coordination-checklist\/\">OR equipment coordination checklist<\/a> ensures that all supporting equipment is specified alongside the robotic system to avoid gaps during installation.<\/p>\n<div class=\"faq-card\">\n<h3>Does robotic surgery require a special operating table?<\/h3>\n<p>Yes. Robotic surgery requires an operating table with specific features: robotic-compatible side rails for docking the patient-side cart, steep Trendelenburg capability (30\u201345\u00b0) with stability under robotic arm forces, and typically a radiolucent carbon fiber tabletop for intraoperative imaging. Standard operating tables without these features cannot safely support robotic procedures.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>How much floor space does a robotic surgery system add to the OR?<\/h3>\n<p>A robotic system adds approximately 3\u20134 m\u00b2 of dedicated equipment footprint (patient cart, surgeon console, and vision tower). Most facilities increase OR size from the traditional 35\u201340 m\u00b2 to 50\u201355 m\u00b2 for robotic procedures to maintain adequate circulation and emergency access space.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>What electrical upgrades are needed for a robotic OR?<\/h3>\n<p>A robotic OR requires dedicated electrical circuits (3\u20135 kVA for the robot), an uninterruptible power supply (UPS) with 15\u201330 minute runtime for safe undocking during power failures, isolated power system with line isolation monitoring, and Ethernet connectivity for the robot&#8217;s data systems. Total electrical upgrade cost typically ranges from $20,000\u201350,000.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>Can robotic surgery be performed in an existing operating room?<\/h3>\n<p>Yes, but with limitations. Existing ORs can accommodate robotic systems if they have adequate floor space (minimum 40 m\u00b2), ceiling height (minimum 3 m for pendant clearance), and electrical capacity. But retrofitting is less efficient than purpose-built robotic ORs. The <a href=\"\/operating-room-suite-planning-rooms-flows-adjacencies\/\">OR suite planning guide<\/a> covers the assessment criteria for robotic retrofit feasibility.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>What is the total cost of equipping a robotic OR?<\/h3>\n<p>Beyond the robotic system itself ($1.5\u20132.5 million), equipping a robotic OR typically costs $200,000\u2013400,000 for supporting equipment including a robotic-compatible operating table, enhanced lighting, additional pendants, UPS system, sterilization containers, and room modifications. Annual maintenance and consumable costs add $150,000\u2013250,000 per year.<\/p>\n<p>For a closer look, see our guide on <a href=\"https:\/\/sanyangmedical.com\/sanyang-medical-equipment-battery-power-trends\/\">medical equipment battery power trends<\/a>.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does robotic surgery require a special operating table?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Robotic surgery requires an operating table with robotic-compatible side rails for docking, steep Trendelenburg capability (30\u201345\u00b0) with stability under robotic arm forces, and typically a radiolucent carbon fiber tabletop for intraoperative imaging.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How much floor space does a robotic surgery system add to the OR?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A robotic system adds approximately 3\u20134 m\u00b2 of dedicated equipment footprint. Most facilities increase OR size from the traditional 35\u201340 m\u00b2 to 50\u201355 m\u00b2 for robotic procedures to maintain adequate circulation and emergency access space.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What electrical upgrades are needed for a robotic OR?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A robotic OR requires dedicated electrical circuits (3\u20135 kVA), UPS with 15\u201330 minute runtime, isolated power system with line isolation monitoring, and Ethernet connectivity. Total electrical upgrade cost typically ranges from $20,000\u201350,000.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can robotic surgery be performed in an existing operating room?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, but with limitations. Existing ORs can accommodate robotic systems if they have adequate floor space (minimum 40 m\u00b2), ceiling height (minimum 3 m), and electrical capacity. But retrofitting is less efficient than purpose-built robotic ORs.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the total cost of equipping a robotic OR?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Beyond the robotic system itself ($1.5\u20132.5 million), equipping a robotic OR typically costs $200,000\u2013400,000 for supporting equipment including a robotic-compatible operating table, enhanced lighting, additional pendants, UPS system, and room modifications.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"name\": \"Robotic Surgery Adoption: What It Means for OR Equipment\",\n  \"description\": \"How robotic surgery adoption changes OR equipment requirements: spatial footprint, operating table specifications, surgical light and pendant needs, power infrastructure, staffing changes, and procurement planning.\",\n  \"author\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Sanyang Medical\"\n  },\n  \"publisher\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Sanyang Medical\"\n  },\n  \"datePublished\": \"2026-08-10\",\n  \"dateModified\": \"2026-08-10\",\n  \"mainEntityOfPage\": {\n    \"@type\": \"WebPage\",\n    \"@id\": \"https:\/\/sanyangmedical.com\/robotic-surgery-operating-room-equipment\/\"\n  }\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"GeoCoordinates\",\n  \"name\": \"Sanyang Medical Equipment\",\n  \"description\": \"Robotic surgery OR equipment requirements: 3-4m\u00b2 additional footprint, robotic-compatible operating table with docking rails and steep Trendelenburg, enhanced surgical lights, additional pendant arms, 3-5kVA dedicated power with UPS, and 50-55m\u00b2 room size for new construction.\"\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Robotic surgery is no longer a niche capability reserved for flagship hospitals. As adoption accelerates across general surgery, urology, gynecology, and thoracic procedures, the operating room itself must evolve. Robotic systems change the spatial requirements, equipment layout, power demands, and staffing patterns of the OR \u2014 and procurement teams need to understand these changes before &#8230; <a title=\"Robotic Surgery Adoption: What It Means for OR Equipment\" class=\"read-more\" href=\"https:\/\/sanyangmedical.com\/es\/robotic-surgery-operating-room-equipment\/\" aria-label=\"Leer m\u00e1s sobre Robotic Surgery Adoption: What It Means for OR Equipment\">Leer m\u00e1s<\/a><\/p>","protected":false},"author":1,"featured_media":3117,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_title":"Robotic Surgery OR Equipment | What Adoption Means for Your OR","rank_math_description":"How robotic surgery changes OR equipment: spatial footprint, table specs, lighting, pendants, power infrastructure, staffing, and procurement planning.","rank_math_focus_keyword":"robotic surgery operating room","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_yoast_wpseo_focuskw":"","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":"","footnotes":""},"categories":[114],"tags":[],"class_list":["post-3708","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-trends"],"_links":{"self":[{"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/posts\/3708","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/comments?post=3708"}],"version-history":[{"count":2,"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/posts\/3708\/revisions"}],"predecessor-version":[{"id":3987,"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/posts\/3708\/revisions\/3987"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/media\/3117"}],"wp:attachment":[{"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/media?parent=3708"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/categories?post=3708"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sanyangmedical.com\/es\/wp-json\/wp\/v2\/tags?post=3708"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}