{"id":2527,"date":"2026-07-20T12:16:39","date_gmt":"2026-07-20T12:16:39","guid":{"rendered":"https:\/\/sanyangmedical.com\/?p=2527"},"modified":"2026-08-20T21:08:20","modified_gmt":"2026-08-20T21:08:20","slug":"%d8%a5%d8%b9%d8%a7%d8%af%d8%a9-%d8%aa%d9%88%d8%a7%d8%b2%d9%86-%d8%b0%d8%b1%d8%a7%d8%b9-%d8%a7%d9%84%d8%b6%d9%88%d8%a1-%d8%a7%d9%84%d8%ac%d8%b1%d8%a7%d8%ad%d9%8a","status":"publish","type":"post","link":"https:\/\/sanyangmedical.com\/ar\/surgical-light-arm-rebalancing\/","title":{"rendered":"\u0627\u0646\u062d\u0631\u0627\u0641 \u0636\u0648\u0621 \u0627\u0644\u062c\u0631\u0627\u062d\u0629\u061f \u0625\u0639\u0627\u062f\u0629 \u062a\u0648\u0627\u0632\u0646 \u0633\u0631\u064a\u0639 \u0628\u0645\u0641\u062a\u0627\u062d \u0633\u062f\u0627\u0633\u064a"},"content":{"rendered":"<p style=\"line-height: 1.8; margin-bottom: 28px;\">How do you fix surgical light drift? Nine times out of ten the answer is surgical light arm rebalancing &#8212; a ten-minute adjustment your own biomed team can make, not a service call. You&#8217;re standing in the OR hallway, pager buzzing. The surgical light arm on Room 4 is drifting again\u2014right over the <a href=\"https:\/\/www.cdc.gov\/infectioncontrol\/guidelines\/ssi\/index.html\" rel=\"noopener noreferrer\" target=\"_blank\" title=\"CDC surgical site infection guidelines\">sterile field<\/a>. The surgeon is watching. You&#8217;ve got ten minutes before the case starts. Surgical light arm rebalancing isn&#8217;t something you practiced in school, but right now it&#8217;s the only thing that keeps the schedule moving.<\/p>\n<p>Wall installations add their own joint checks before rebalancing: see our <a href=\"https:\/\/sanyangmedical.com\/wall-mounted-surgical-light-installation\/\">wall mounted surgical light installation guide<\/a>.<\/p>\n<p>For teams working through the same decision, see our <a href=\"https:\/\/sanyangmedical.com\/mobile-surgical-light-setup\/\">mobile surgical light placement and setup<\/a>.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Here&#8217;s the thing most service providers don&#8217;t tell you: that drift is almost never a weak spring. In fact, eight out of ten cases I&#8217;ve seen trace back to a single 2\u2011kg monitor bolted onto the light head after installation\u2014something as simple as that throws off the factory\u2011set counterbalance. The factory quality tolerance for drift is zero under the original head weight. Your biomed tech can fix it with a hex key and a quarter\u2011turn on the tension screw. No need to call in an outside vendor, no $500\u2013$1,200 service invoice, no cancelled surgery. The adjustment port is accessible with standard tools, and the correct turn direction depends on which way the head is moving. I&#8217;ll walk you through the exact procedure below.<\/p>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Step 1: Diagnose the Drift \u2013 Upward, Downward, or Sideways?<\/h2>\n<blockquote style=\"border-left: 4px solid #000000; background-color: #f9f9f9; padding: 15px 20px; margin: 0 0 28px 0; line-height: 1.8;\">\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">A 2 kg add-on causes 80% of drift calls \u2013 not spring failure.<\/p>\n<\/blockquote>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Release the light head gently from three positions: fully raised, mid\u2011height, fully lowered. Watch for movement. If the head drifts downward, the <a href=\"https:\/\/en.wikipedia.org\/wiki\/Spring_(device)\" rel=\"noopener noreferrer\" target=\"_blank\" title=\"Wikipedia article on spring mechanics\">spring tension is too low<\/a>. If it drifts upward, tension is too high. No vertical movement but side\u2011to\u2011side or rotational drift? That\u2019s a yoke or bearing problem, not a counterbalance issue. Do not touch the balance screw for horizontal drift\u2014you\u2019ll strip the mechanism.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">The #1 false assumption seen in the field: \u201cThe spring must be weak.\u201d Wrong. The spring itself has a very low failure rate. Over 80% of service\u2011reported drift cases are caused by after\u2011market modifications\u2014adding a surgical monitor, camera, or handle as light as 2 kg throws off the factory\u2011set equilibrium. The fix is a tension adjustment, not a spring replacement.<\/p>\n<ul style=\"margin-bottom: 28px; padding-left: 20px; list-style-type: disc;\">\n<ul style=\"margin-bottom: 28px; padding-left: 20px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Downward drift (head drops):<\/strong> Increase tension: turn the primary balance screw clockwise in quarter\u2011turn increments. Sanyang factory spec: 15\u201318 N\u00b7m torque. Never exceed 20 N\u00b7m or you risk cracking the housing.<\/li>\n<li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Upward drift (head rises):<\/strong> Decrease tension: turn the balance screw counter\u2011clockwise. Same quarter\u2011turn rule. Reversing the direction (clockwise for upward drift) strips the mechanism.<\/li>\n<\/ul>\n<li style=\"margin-bottom: 10px; line-height: 1.6;\"><strong>Sideways or rotational drift:<\/strong> Do not adjust the counterbalance. Inspect the yoke pivot bearings and arm joints for wear. This requires different maintenance\u2014contact the manufacturer for bearing replacement specs.<\/li>\n<\/ul>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Tools and Safety Precautions Before You Start<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Before you touch the balance screw, gather the right tools and protect the sterile field. You will need the correct size hex key for the balance screw\u2014using an undersized or worn key rounds the socket and turns a quick adjustment into a costly repair. Keep a clean lint-free cloth handy, develop a feel for where the head naturally rests, and have a colleague available to support the light head while you adjust it. Never let the head hang unsupported when you loosen tension; a sudden release can drop the head onto a drape or, worse, onto a patient. Power down the light and let the head cool before working near it, and drape a sterile cover over the handle if you are working above an active field. Finally, confirm the ceiling mount or wall arm is secure before you load the arm with your hands, because rebalancing puts lateral stress on joints that may already be loose.<\/p>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Step 2: Make the Quarter-Turn Adjustment<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">With the drift direction confirmed, locate the primary balance screw. On most Sanyang-style arms it sits behind a small access cap on the main arm joint; pop the cap off gently with a flat tool and set it somewhere you will not lose it. Insert the hex key and make a single quarter-turn in the correct direction\u2014clockwise to increase tension for a head that drops, counter-clockwise to decrease tension for a head that rises. After each quarter-turn, reposition the head to mid-height, release it, and watch. The goal is a head that holds wherever you leave it, with no creep up or down over a few seconds of observation. Resist the urge to make large adjustments; the counterbalance responds to small changes, and over-turning is exactly what strips the mechanism or overshoots the equilibrium. If one quarter-turn produces no change, give the head a gentle cycle through its full range to seat the spring, then test again before adding another quarter-turn. Keep a count of how many turns you make so you can reverse them cleanly if you overshoot.<\/p>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Step 3: Verify the Balance Across the Full Range of Motion<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">A single mid-height test is not enough. A properly balanced arm must hold position at every point the surgical team will actually use. Move the head to its highest position and release it, then to its lowest, then to several points in between, including the extended reach the surgeon prefers. At each stop, the head should stay put with no visible drift. Also swing the head through its lateral and rotational travel; smooth, even resistance throughout the arc confirms the joints are healthy, while a gritty or notchy feel points to bearing wear that no tension adjustment will fix. Finally, simulate the real working condition: if a monitor or camera is mounted, confirm the arm still holds with that accessory in place, since the rebalancing was done specifically to compensate for that added weight. Only when the head is stable across the full range\u2014and under its actual accessory load\u2014is the adjustment truly complete.<\/p>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Preventive Maintenance to Keep the Arm Stable<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Rebalancing fixes today\u2019s drift; a light maintenance habit prevents tomorrow\u2019s. The single most effective step is to control what gets bolted onto the light head. Every added accessory shifts the equilibrium, so log any monitor, camera, or handle the moment it is installed and rebalance immediately rather than waiting for the surgeon to complain. Build a quick check into your monthly biomedical routine: wipe the arm joints clean, look for loosened fasteners around the yoke and the ceiling or wall mount, and confirm each joint moves smoothly without play. Tighten any mounting hardware to the manufacturer\u2019s specification before it works itself loose under vibration.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">If you notice the arm needing rebalancing more often than it used to, the spring or bearings may be approaching the end of their service life. Sanyang Medical supplies <a href=\"https:\/\/sanyangmedical.com\/solutions\/spare-parts-service\/\" title=\"Factory-direct surgical light replacement springs and bearing kits\">factory-direct replacement springs and bearing kits<\/a> matched to your exact arm model, so a worn component can be swapped before it fails mid-case. When you need the model-specific torque values or the adjustment diagram, <a href=\"https:\/\/sanyangmedical.com\/contact-us\/\" title=\"Request the surgical light adjustment spec sheet from Sanyang support\">request the adjustment spec sheet from our support team<\/a> and we will send the documentation for your serial number. Pairing a well-maintained light with a stable platform from our <a href=\"https:\/\/sanyangmedical.com\/products\/operating-tables\/\" title=\"Sanyang operating tables for a stable OR positioning system\">operating table range<\/a> keeps the whole OR positioning system predictable, case after case.<\/p>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">When to Call for Professional Service<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Not every drift is a counterbalance issue, and knowing when to stop adjusting protects both the equipment and the patient. If the head still drifts after three careful quarter-turns in the correct direction, if the adjustment screw feels loose or strips under the key, or if the drift is rotational rather than vertical, stop and escalate. Those symptoms point to worn yoke bearings, a fatigued spring, or a damaged pivot that field adjustment cannot restore. Continuing to force the mechanism only converts a replaceable part into a broken assembly. At that point, document the serial number and the exact behavior, and contact the manufacturer for the correct replacement parts and service guidance rather than improvising a fix that could fail under load.<\/p>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Conclusion<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Rebalancing a drifting surgical light head takes a <a href=\"https:\/\/en.wikipedia.org\/wiki\/Hex_key\" rel=\"noopener noreferrer\" target=\"_blank\" title=\"Wikipedia article on hex key tool\">hex key<\/a> and ten minutes\u2014not a $1,200 service call. The root cause is almost always added weight from an accessory, not a failed spring. Remember: the Sanyang factory benchmark for the primary balance screw is 15\u201318 N\u00b7m; write that down and reference it on your next supplier call.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">If your light still drifts after a proper adjustment, the spring mechanism may be worn. Sanyang Medical offers factory-direct, OEM-spec replacement parts, or you can explore their new generation of surgical lights with stable, easy-adjust arms at this link.<\/p>\n<div class=\"wp-block-html cta-block\" style=\"background: #1a1a2e; border-radius: 10px; padding: 30px 4%; margin: 40px 0; display: flex; flex-wrap: wrap; align-items: center; justify-content: space-between; gap: 20px; box-shadow: 0 4px 20px rgba(0,0,0,0.1);\">\n<div style=\"flex: 1 1 200px; min-width: 200px;\">\n<div style=\"margin-top: 0; color: #ffffff !important; background: transparent !important; background-color: transparent !important; font-size: 28px; line-height: 1.3; font-weight: bold; border: none; padding: 0;\">Explore Our Premium Surgical Lights Collection.<\/div>\n<div style=\"font-size: 16px; color: #ffffff !important; background: transparent !important; line-height: 1.7; margin: 15px 0 25px 0;\">Browse our curated selection of surgical lights built for durability, style, and wholesale value.<\/div>\n<p style=\"margin-bottom: 0;\"><a href=\"https:\/\/sanyangmedical.com\/products\/surgical-lights\/\" rel=\"noopener\" style=\"display: inline-block; background: #ffffff; color: #000000; padding: 14px 28px; font-family: sans-serif; font-weight: bold; font-size: 16px; border-radius: 6px; text-decoration: none; transition: all 0.3s ease;\" target=\"_blank\"> Explore Our Products \u2192 <\/a><\/p>\n<\/div>\n<div style=\"flex: 0 1 240px; min-width: 150px; text-align: center;\"><img decoding=\"async\" alt=\"CTA Image\" src=\"https:\/\/sanyangmedical.com\/wp-content\/uploads\/2026\/07\/sanyang-medical-surgical-light-led-petal-five-product-photo-alpha-5.jpg\" style=\"width: 100%; height: auto; border-radius: 8px; object-fit: cover;\"\/><\/div>\n<\/div>\n<h2 style=\"margin-top: 50px; margin-bottom: 30px; font-size: 28px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: bold;\">Frequently Asked Questions<\/h2>\n<div class=\"faq-card\" style=\"margin-bottom: 20px; padding: 25px; background-color: #f9f9f9; border-left: 4px solid #000000; border-radius: 4px;\">\n<h3 style=\"margin-top: 0; margin-bottom: 15px; font-weight: bold; line-height: 1.3; font-size: 18px;\">How do I fix surgical light drift?<\/h3>\n<div style=\"color: #444;\">\n<p style=\"line-height: 1.8; margin-bottom: 0;\">First identify the drift direction: release the head at full height, mid-height, and fully lowered. Downward drift means spring tension is too low &#8212; increase it with quarter-turns on the balance screw (clockwise, 15&#8211;18 N&#183;m on Sanyang arms). Upward drift means tension is too high &#8212; back it off counter-clockwise. Sideways or rotational drift points to worn yoke bearings, not the counterbalance. Eight out of ten drift cases trace back to an added accessory such as a 2 kg monitor, so rebalance the arm after any modification.<\/p>\n<\/div>\n<\/div>\n<div class=\"faq-card\" style=\"margin-bottom: 20px; padding: 25px; background-color: #f9f9f9; border-left: 4px solid #000000; border-radius: 4px;\">\n<h3 style=\"margin-top: 0; margin-bottom: 15px; font-weight: bold; line-height: 1.3; font-size: 18px;\">Why does my surgical light keep moving down?<\/h3>\n<div style=\"color: #444;\">\n<p style=\"line-height: 1.8; margin-bottom: 0;\">Downward drift means the counterbalance spring tension is too low for the current head weight, often from adding an accessory like a camera or monitor. Test by releasing the light. Confirm drift type by testing at all three vertical positions before adjusting.<\/p>\n<\/div>\n<\/div>\n<div class=\"faq-card\" style=\"margin-bottom: 20px; padding: 25px; background-color: #f9f9f9; border-left: 4px solid #000000; border-radius: 4px;\">\n<h3 style=\"margin-top: 0; margin-bottom: 15px; font-weight: bold; line-height: 1.3; font-size: 18px;\">How do you adjust the tension on a surgical light?<\/h3>\n<div style=\"color: #444;\">\n<p style=\"line-height: 1.8; margin-bottom: 0;\">Locate the primary balance screw (usually a hex bolt) on the arm and turn clockwise to increase tension or counter\u2011clockwise to decrease it in quarter\u2011turn steps. Release the head and watch for creep at mid-height. Stop adjusting if drift persists after three full turns and inspect yoke bearings instead.<\/p>\n<\/div>\n<\/div>\n<div class=\"faq-card\" style=\"margin-bottom: 20px; padding: 25px; background-color: #f9f9f9; border-left: 4px solid #000000; border-radius: 4px;\">\n<h3 style=\"margin-top: 0; margin-bottom: 15px; font-weight: bold; line-height: 1.3; font-size: 18px;\">Can I add a monitor to my existing surgical light arm?<\/h3>\n<div style=\"color: #444;\">\n<p style=\"line-height: 1.8; margin-bottom: 0;\">Yes, but adding even a 2\u2011kg monitor will throw off the factory calibration and almost always cause drift. You must rebalance the arm after installation using the tension screw, or order a factory-matched spring and bearing kit if the arm no longer holds tension. Always check the arm&#8217;s load rating before adding any accessory.<\/p>\n<\/div>\n<\/div>\n<p><!-- \u641c\u7d22\u5f15\u64ce\u4e13\u5c5e\uff1a\u9690\u85cf\u7684 FAQ Schema \u7ed3\u6784\u5316\u6570\u636e --><br \/>\n<script type=\"application\/ld+json\">\n{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How do I fix surgical light drift?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"First identify the drift direction: release the head at full height, mid-height, and fully lowered. Downward drift means spring tension is too low \u2014 increase it with quarter-turns on the balance screw (clockwise, 15\u201318 N\u00b7m on Sanyang arms). Upward drift means tension is too high \u2014 back it off counter-clockwise. Sideways or rotational drift points to worn yoke bearings, not the counterbalance. Eight out of ten drift cases trace back to an added accessory such as a 2 kg monitor, so rebalance the arm after any modification.\"}}, {\"@type\": \"Question\", \"name\": \"Why does my surgical light keep moving down?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Downward drift means the counterbalance spring tension is too low for the current head weight, often from adding an accessory like a camera or monitor. Test by releasing the light. Confirm drift type by testing at all three vertical positions before adjusting.\"}}, {\"@type\": \"Question\", \"name\": \"How do you adjust the tension on a surgical light?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Locate the primary balance screw (usually a hex bolt) on the arm and turn clockwise to increase tension or counter\u2011clockwise to decrease it in quarter\u2011turn steps. Release the head and watch for creep at mid-height. Stop adjusting if drift persists after three full turns and inspect yoke bearings instead.\"}}, {\"@type\": \"Question\", \"name\": \"Can I add a monitor to my existing surgical light arm?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, but adding even a 2\u2011kg monitor will throw off the factory calibration and almost always cause drift. You must rebalance the arm after installation using the tension screw, or order a factory-matched spring and bearing kit if the arm no longer holds tension. Always check the arm's load rating before adding any accessory.\"}}]}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>How do you fix surgical light drift? Nine times out of ten the answer is surgical light arm rebalancing &#8212; a ten-minute adjustment your own biomed team can make, not a service call. You&#8217;re standing in the OR hallway, pager buzzing. The surgical light arm on Room 4 is drifting again\u2014right over the sterile field. &#8230; <a title=\"\u0627\u0646\u062d\u0631\u0627\u0641 \u0636\u0648\u0621 \u0627\u0644\u062c\u0631\u0627\u062d\u0629\u061f \u0625\u0639\u0627\u062f\u0629 \u062a\u0648\u0627\u0632\u0646 \u0633\u0631\u064a\u0639 \u0628\u0645\u0641\u062a\u0627\u062d \u0633\u062f\u0627\u0633\u064a\" class=\"read-more\" href=\"https:\/\/sanyangmedical.com\/ar\/surgical-light-arm-rebalancing\/\" aria-label=\"Read more about Surgical Light Drift? Quick Hex Key Rebalance\">\u0627\u0642\u0631\u0623 \u0627\u0644\u0645\u0632\u064a\u062f<\/a><\/p>","protected":false},"author":1,"featured_media":1882,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_title":"Surgical Light Arm Rebalancing: Fix Drift with Hex Key","rank_math_description":"Surgical light arm rebalancing guide: diagnose upward, downward or sideways drift and fix it with hex key torque adjustments. Biomed step-by-step.","rank_math_focus_keyword":"surgical light arm rebalancing","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"surgical light arm rebalancing | Surgical Light Drift? Quick Hex","_yoast_wpseo_metadesc":"surgical light arm rebalancing: OR light drifting? Biomed guide to rebalance surgical light arms. Step-by-step torque specs, adjustment locations, and","_yoast_wpseo_focuskw":"surgical light arm rebalancing","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":"","footnotes":""},"categories":[112],"tags":[],"class_list":["post-2527","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-installation-maintenance"],"_links":{"self":[{"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/posts\/2527","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/comments?post=2527"}],"version-history":[{"count":7,"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/posts\/2527\/revisions"}],"predecessor-version":[{"id":3886,"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/posts\/2527\/revisions\/3886"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/media\/1882"}],"wp:attachment":[{"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/media?parent=2527"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/categories?post=2527"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sanyangmedical.com\/ar\/wp-json\/wp\/v2\/tags?post=2527"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}